Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
Cable Type
ATX connector 24 pin (600mm)
1
1
16-20AWG
Tinned Copper
4+4 pin EPS12V (750mm)
2
2
18AWG
Tinned Copper
6+2 pin PCIe (600mm)
1
1
16AWG
Tinned Copper
12+4 pin PCIe (600mm) (600W)
2
2
16-24AWG
Tinned Copper
SATA (500mm+150mm+150mm+150mm)
2
8
18AWG
Tinned Copper
4-pin Molex (500mm+150mm+150mm+150mm)
1
4
18AWG
Tinned Copper
AC Power Cord (1390mm) - C13 coupler
1
1
18AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
效率評比
PLATINUM
噪音評比
A
Average Efficiency (>1450 load combinations)
89.065%
Average Noise Output (>1450 Load Combinations)
20.88dBA
Average PF (>1450 Load Combinations)
0.990
Efficiency With 10W (≤500W) or 2% (>500W) Load
76.547%
Standby Power Consumption
0.0149W
12V Ripple (Full Load)
27.17mV
5V Ripple (Full Load)
22.71mV
3.3V Ripple (Full Load)
23.52mV
5VSB Ripple (Full Load)
16.95mV
12V Load Regulation
0.93%
5V Load Regulation
1.02%
3.3V Load Regulation
1.63%
5VSB Load Regulation
1.22%
Inrush Current
Too low to detect
效率評比
PLATINUM
噪音評比
A
Average Efficiency (>1450 load combinations)
91.034%
Average Noise Output (>1450 Load Combinations)
20.83dBA
Average PF (>1450 Load Combinations)
0.978
Efficiency With 10W (≤500W) or 2% (>500W) Load
60.396%
Standby Power Consumption
0.0787W
12V Ripple (Full Load)
28.26mV
5V Ripple (Full Load)
22.90mV
3.3V Ripple (Full Load)
24.99mV
5VSB Ripple (Full Load)
14.32mV
12V Load Regulation
0.90%
5V Load Regulation
1.00%
3.3V Load Regulation
1.63%
5VSB Load Regulation
1.20%
Inrush Current
Too low to detect
12V Transient Response (200%)
11.08V
5V Transient Response (200%)
4.884V
3.3V Transient Response (200%)
3.214V
5VSB Transient Response (200%)
4.873V
Hold-Up Time & Power Ok Signal
26.80ms
AC Loss to PWR_OK Hold Up Time
22.80ms
PWR_OK Inactive to DC Loss Delay
4.00ms
PSU Timings: T1 (20% / 100%)
96.0ms
68.0ms
PSU Timings: T3 (20% / 100%)
132.0ms
129.0ms
12V OCP (27.5°C / 45.5°C)
127.40A (122.38%), 12.031V
122.80A (117.96%), 12.027V
5V OCP (27.5°C / 45.5°C)
28.8A (130.91%), 5.022V
27.2A (123.64%), 5.011V
3.3V OCP (27.5°C / 45.5°C)
28.6A (130.00%), 3.348V
27.2A (123.64%), 3.337V
5VSB OCP (27.5°C / 45.5°C)
5.2A (173.33%), 5.03V
5.1A (170.00%), 5.031V
OPP (28.55°C / 46.00°C)
124.15%
119.79%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
26.8
AC Loss to PWR_OK Hold Up Time (ms)
22.8
PWR_OK Inactive to DC Loss Delay (ms)
4
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.02 V
114.99 V
113.85 V
115.08 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.96 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.417
1.490
PASS
Mains Voltage THD:
0.13 %
0.11 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.015 W
0.001 W
N/A
0.030 W
N/A
N/A
Apparent Power:
12.322 W
12.302 W
N/A
12.343 W
N/A
N/A
Power Factor:
0.001
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
230.00 V
229.97 V
227.70 V
230.02 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.00 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.15 %
0.13 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.079 W
0.041 W
N/A
0.128 W
N/A
N/A
Apparent Power:
40.690 W
40.650 W
N/A
40.726 W
N/A
N/A
Power Factor:
0.001
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input