Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
Cable Type
ATX connector 20+4 pin (300mm)
1
1
18-22AWG
Tinned Copper
4+4 pin EPS12V (410mm)
2
2
18AWG
Tinned Copper
6+2 pin PCIe (410mm+100mm)
1
2
18AWG
Tinned Copper
6+2 pin PCIe (410mm+100mm)
1
2
18AWG
Copper
12+4 pin PCIe (410mm) (600W)
1
1
16-24AWG
Tinned Copper
SATA (110mm+100mm+100mm+100mm)
2
8
18AWG
Tinned Copper
4-pin Molex (110mm+100mm+100mm)
1
3
18AWG
Tinned Copper
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
PLATINUM
Lautstärkeklasse
Standard++
Average Efficiency (>1450 load combinations)
90.153%
Average Noise Output (>1450 Load Combinations)
32.12dBA
Average PF (>1450 Load Combinations)
0.983
Efficiency With 10W (≤500W) or 2% (>500W) Load
67.520%
Standby Power Consumption
0.0371W
12V Ripple (Full Load)
44.08mV
5V Ripple (Full Load)
16.02mV
3.3V Ripple (Full Load)
13.91mV
5VSB Ripple (Full Load)
17.08mV
12V Load Regulation
0.22%
5V Load Regulation
0.22%
3.3V Load Regulation
0.69%
5VSB Load Regulation
1.55%
Inrush Current
Too low to detect
Wirkungsgrad
PLATINUM
Lautstärkeklasse
Standard++
Average Efficiency (>1450 load combinations)
92.045%
Average Noise Output (>1450 Load Combinations)
32.04dBA
Average PF (>1450 Load Combinations)
0.944
Efficiency With 10W (≤500W) or 2% (>500W) Load
57.050%
Standby Power Consumption
0.0815W
12V Ripple (Full Load)
44.93mV
5V Ripple (Full Load)
16.80mV
3.3V Ripple (Full Load)
13.27mV
5VSB Ripple (Full Load)
16.11mV
12V Load Regulation
0.34%
5V Load Regulation
0.32%
3.3V Load Regulation
0.90%
5VSB Load Regulation
1.55%
Inrush Current
Too low to detect
12V Transient Response (200%)
11.60V
5V Transient Response (200%)
4.965V
3.3V Transient Response (200%)
3.258V
5VSB Transient Response (200%)
4.963V
Hold-Up Time & Power Ok Signal
18.40ms
AC Loss to PWR_OK Hold Up Time
15.70ms
PWR_OK Inactive to DC Loss Delay
2.70ms
PSU Timings: T1 (20% / 100%)
42.0ms
42.0ms
PSU Timings: T3 (20% / 100%)
128.0ms
128.0ms
12V OCP (28.7°C / 43.8°C)
92.60A (148.16%), 12.061V
90.00A (144.00%), 12.063V
5V OCP (28.7°C / 43.8°C)
25.3A (126.50%), 5.041V
25.4A (127.00%), 5.045V
3.3V OCP (28.7°C / 43.8°C)
26.1A (130.50%), 3.345V
25.1A (125.50%), 3.343V
5VSB OCP (28.7°C / 43.8°C)
3.7A (148.00%), 4.99V
3.5A (140.00%), 4.986V
OPP (30.34°C / 42.84°C)
147.02%
142.33%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
18.4
AC Loss to PWR_OK Hold Up Time (ms)
15.7
PWR_OK Inactive to DC Loss Delay (ms)
2.7
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.05 V
115.02 V
113.85 V
115.13 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.13 %
0.10 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.037 W
-0.006 W
N/A
0.071 W
N/A
N/A
Apparent Power:
7.282 W
7.258 W
N/A
7.307 W
N/A
N/A
Power Factor:
0.006
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
230.10 V
230.07 V
227.70 V
230.10 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.00 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.15 %
0.13 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.082 W
0.040 W
N/A
0.136 W
N/A
N/A
Apparent Power:
23.241 W
23.205 W
N/A
23.273 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input