Globe Fan S0921512HHB (92mm, 12V, 0.50A, Fluid Dynamic Bearing Fan)
5VSB Circuit
Rectifier
First Semiconductor FIR4N70L (700V, 2.5A @ 100°C, Rds(on) 3.0mOhm)
Standby PWM Controller
INFSitronix IN2P070C
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
PLATINUM
Lautstärkeklasse
Standard+
Average Efficiency (>1450 load combinations)
90.524%
Average Noise Output (>1450 Load Combinations)
36.02dBA
Average PF (>1450 Load Combinations)
0.989
Efficiency With 10W (≤500W) or 2% (>500W) Load
74.431%
Standby Power Consumption
0.0808W
12V Ripple (Full Load)
32.57mV
5V Ripple (Full Load)
11.43mV
3.3V Ripple (Full Load)
11.41mV
5VSB Ripple (Full Load)
10.37mV
12V Load Regulation
0.66%
5V Load Regulation
0.54%
3.3V Load Regulation
0.55%
5VSB Load Regulation
2.59%
Inrush Current
21.600A
Wirkungsgrad
PLATINUM
Lautstärkeklasse
Standard+
Average Efficiency (>1450 load combinations)
92.522%
Average Noise Output (>1450 Load Combinations)
36.51dBA
Average PF (>1450 Load Combinations)
0.947
Efficiency With 10W (≤500W) or 2% (>500W) Load
76.927%
Standby Power Consumption
0.1549W
12V Ripple (Full Load)
34.52mV
5V Ripple (Full Load)
10.97mV
3.3V Ripple (Full Load)
11.47mV
5VSB Ripple (Full Load)
9.65mV
12V Load Regulation
0.61%
5V Load Regulation
0.54%
3.3V Load Regulation
0.55%
5VSB Load Regulation
2.55%
Inrush Current
37.910A
12V Transient Response (200%)
11.42V
5V Transient Response (200%)
4.866V
3.3V Transient Response (200%)
3.232V
5VSB Transient Response (200%)
4.958V
Hold-Up Time & Power Ok Signal
14.10ms
AC Loss to PWR_OK Hold Up Time
12.50ms
PWR_OK Inactive to DC Loss Delay
1.60ms
PSU Timings: T1 (20% / 100%)
97.0ms
100.0ms
PSU Timings: T3 (20% / 100%)
112.0ms
112.0ms
12V OCP (28.3°C / 43.2°C)
112.00A (134.45%), 12.073V
103.40A (124.13%), 12.066V
5V OCP (28.3°C / 43.2°C)
25A (125.00%), 4.963V
24.7A (123.50%), 4.963V
3.3V OCP (28.3°C / 43.2°C)
28.6A (143.00%), 3.306V
28.2A (141.00%), 3.308V
5VSB OCP (28.3°C / 43.2°C)
4.5A (150.00%), 4.992V* High Ripple (>200mV)
4.5A (150.00%), 4.97V* High Ripple (>200mV)
OPP (29.41°C / 42.76°C)
134.36%
124.65%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
14.1
AC Loss to PWR_OK Hold Up Time (ms)
12.5
PWR_OK Inactive to DC Loss Delay (ms)
1.6
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.05 V
115.02 V
113.85 V
115.06 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
60.00 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.417
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.18 %
2.00 %
PASS
Real Power:
0.081 W
0.054 W
N/A
0.124 W
N/A
N/A
Apparent Power:
12.447 W
12.426 W
N/A
12.469 W
N/A
N/A
Power Factor:
0.007
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
230.10 V
230.07 V
227.70 V
230.11 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.00 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.15 %
0.13 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.155 W
0.108 W
N/A
0.239 W
N/A
N/A
Apparent Power:
41.005 W
40.975 W
N/A
41.037 W
N/A
N/A
Power Factor:
0.003
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input