4.2A (140.00%), 4.751V *Voltage Drop (4.688V@5.1A)
4.9A (163.33%), 4.751V *Voltage Drop (4.729V@5.2A)
OPP (28.45°C / 45.18°C)
149.72%
128.25%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
19.9
AC Loss to PWR_OK Hold Up Time (ms)
16
PWR_OK Inactive to DC Loss Delay (ms)
3.9
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.08 V
115.03 V
113.85 V
115.14 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.94 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.13 %
0.11 %
N/A
0.15 %
2.00 %
PASS
Real Power:
0.052 W
-0.004 W
N/A
0.091 W
N/A
N/A
Apparent Power:
6.850 W
6.829 W
N/A
6.872 W
N/A
N/A
Power Factor:
0.009
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
230.07 V
230.04 V
227.70 V
230.12 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.00 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.14 %
0.13 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.171 W
0.123 W
N/A
0.226 W
N/A
N/A
Apparent Power:
21.930 W
21.877 W
N/A
21.975 W
N/A
N/A
Power Factor:
0.009
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input