Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
Cable Type
ATX connector 20+4 pin (600mm)
1
1
16AWG
Tinned Copper
4+4 pin EPS12V (700mm)
2
2
16AWG
Tinned Copper
2x 6+2 pin PCIe (550mm)
2
2
18AWG
Tinned Copper
6+2 pin PCIe (550mm)
3
3
16AWG
Tinned Copper
12+4 pin PCIe (600mm) (600W)
1
1
16-24AWG
Tinned Copper
SATA (450mm+155mm+155mm+155mm)
2
8
18AWG
Tinned Copper
4-pin Molex (450mm+150mm+150mm+150mm)
1
4
18AWG
Tinned Copper
AC Power Cord (1410mm) - C13 coupler
1
1
16AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
效率評比
PLATINUM
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
90.470%
Average Noise Output (>1450 Load Combinations)
31.60dBA
Average PF (>1450 Load Combinations)
0.991
Efficiency With 10W (≤500W) or 2% (>500W) Load
74.181%
Standby Power Consumption
0.0400W
12V Ripple (Full Load)
32.13mV
5V Ripple (Full Load)
34.94mV
3.3V Ripple (Full Load)
28.70mV
5VSB Ripple (Full Load)
20.41mV
12V Load Regulation
0.43%
5V Load Regulation
0.36%
3.3V Load Regulation
1.03%
5VSB Load Regulation
2.12%
Inrush Current
26.580A
效率評比
PLATINUM
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
92.326%
Average Noise Output (>1450 Load Combinations)
31.25dBA
Average PF (>1450 Load Combinations)
0.965
Efficiency With 10W (≤500W) or 2% (>500W) Load
73.601%
Standby Power Consumption
0.1059W
12V Ripple (Full Load)
31.51mV
5V Ripple (Full Load)
34.49mV
3.3V Ripple (Full Load)
33.81mV
5VSB Ripple (Full Load)
19.85mV
12V Load Regulation
0.43%
5V Load Regulation
0.28%
3.3V Load Regulation
1.03%
5VSB Load Regulation
2.12%
Inrush Current
51.940A
12V Transient Response (200%)
11.39V
5V Transient Response (200%)
4.932V
3.3V Transient Response (200%)
3.226V
5VSB Transient Response (200%)
4.993V
Hold-Up Time & Power Ok Signal
20.40ms
AC Loss to PWR_OK Hold Up Time
18.10ms
PWR_OK Inactive to DC Loss Delay
2.30ms
PSU Timings: T1 (20% / 100%)
100.0ms
102.0ms
PSU Timings: T3 (20% / 100%)
135.0ms
136.0ms
12V OCP (28.8°C / 42.3°C)
119.40A (119.40%), 12.033V
117.20A (117.20%), 12.030V
5V OCP (28.8°C / 42.3°C)
24A (120.00%), 5.031V
23.3A (116.50%), 5.032V
3.3V OCP (28.8°C / 42.3°C)
23.3A (116.50%), 3.305V
23.1A (115.50%), 3.308V
5VSB OCP (28.8°C / 42.3°C)
4.2A (140.00%), 5.031V
4.2A (140.00%), 5.031V
OPP (28.04°C / 41.59°C)
119.63%
117.50%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
20.4
AC Loss to PWR_OK Hold Up Time (ms)
18.1
PWR_OK Inactive to DC Loss Delay (ms)
2.3
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.06 V
115.05 V
113.85 V
115.09 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
60.00 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.13 %
0.11 %
N/A
0.15 %
2.00 %
PASS
Real Power:
0.040 W
-0.008 W
N/A
0.073 W
N/A
N/A
Apparent Power:
10.370 W
10.345 W
N/A
10.392 W
N/A
N/A
Power Factor:
0.005
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
230.15 V
230.12 V
227.70 V
230.16 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.00 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.14 %
0.13 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.106 W
0.060 W
N/A
0.205 W
N/A
N/A
Apparent Power:
33.951 W
33.912 W
N/A
33.990 W
N/A
N/A
Power Factor:
0.003
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input