Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
Cable Type
ATX connector 20+4 pin (600mm)
1
1
16AWG
Tinned Copper
4+4 pin EPS12V (700mm)
2
2
16AWG
Tinned Copper
2x 6+2 pin PCIe (550mm)
2
2
18AWG
Tinned Copper
6+2 pin PCIe (550mm)
3
3
16AWG
Tinned Copper
12+4 pin PCIe (600mm) (600W)
1
1
16-24AWG
Tinned Copper
SATA (450mm+155mm+155mm+155mm)
2
8
18AWG
Tinned Copper
4-pin Molex (450mm+150mm+150mm+150mm)
1
4
18AWG
Tinned Copper
AC Power Cord (1410mm) - C13 coupler
1
1
16AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
效率評比
PLATINUM
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
90.716%
Average Noise Output (>1450 Load Combinations)
32.88dBA
Average PF (>1450 Load Combinations)
0.990
Efficiency With 10W (≤500W) or 2% (>500W) Load
75.220%
Standby Power Consumption
0.0339W
12V Ripple (Full Load)
31.15mV
5V Ripple (Full Load)
34.50mV
3.3V Ripple (Full Load)
29.46mV
5VSB Ripple (Full Load)
15.15mV
12V Load Regulation
0.25%
5V Load Regulation
0.26%
3.3V Load Regulation
0.87%
5VSB Load Regulation
2.33%
Inrush Current
19.720A
效率評比
PLATINUM
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
92.544%
Average Noise Output (>1450 Load Combinations)
31.88dBA
Average PF (>1450 Load Combinations)
0.958
Efficiency With 10W (≤500W) or 2% (>500W) Load
74.557%
Standby Power Consumption
0.1041W
12V Ripple (Full Load)
25.46mV
5V Ripple (Full Load)
39.50mV
3.3V Ripple (Full Load)
29.73mV
5VSB Ripple (Full Load)
14.83mV
12V Load Regulation
0.22%
5V Load Regulation
0.26%
3.3V Load Regulation
0.81%
5VSB Load Regulation
2.28%
Inrush Current
55.610A
12V Transient Response (200%)
11.47V
5V Transient Response (200%)
4.946V
3.3V Transient Response (200%)
3.261V
5VSB Transient Response (200%)
5.009V
Hold-Up Time & Power Ok Signal
19.00ms
AC Loss to PWR_OK Hold Up Time
17.30ms
PWR_OK Inactive to DC Loss Delay
1.70ms
PSU Timings: T1 (20% / 100%)
108.0ms
106.0ms
PSU Timings: T3 (20% / 100%)
116.0ms
117.0ms
12V OCP (28.1°C / 42.9°C)
96.80A (116.21%), 12.018V
95.60A (114.77%), 12.017V
5V OCP (28.1°C / 42.9°C)
23.5A (117.50%), 5.027V
23.7A (118.50%), 5.028V
3.3V OCP (28.1°C / 42.9°C)
23.7A (118.50%), 3.321V
23.6A (118.00%), 3.319V
5VSB OCP (28.1°C / 42.9°C)
4.1A (136.67%), 4.996V
4.1A (136.67%), 4.995V
OPP (28.66°C / 40.93°C)
115.10%
114.85%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
19
AC Loss to PWR_OK Hold Up Time (ms)
17.3
PWR_OK Inactive to DC Loss Delay (ms)
1.7
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.03 V
115.02 V
113.85 V
115.07 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.13 %
0.10 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.034 W
-0.008 W
N/A
0.072 W
N/A
N/A
Apparent Power:
9.992 W
9.967 W
N/A
10.017 W
N/A
N/A
Power Factor:
0.007
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
230.12 V
230.09 V
227.70 V
230.14 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.00 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.14 %
0.13 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.104 W
0.061 W
N/A
0.147 W
N/A
N/A
Apparent Power:
32.637 W
32.603 W
N/A
32.670 W
N/A
N/A
Power Factor:
0.003
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input