| 230V | |
| Scheme: ETA-EMI PSU | ![]() |
| 230V | |
![]() |
Scheme: LAMBDA PSU |
Outside Validation Scope

| Load range | Points | Efficiency 230V | PF 230V |
|---|---|---|---|
| 0-<20 % | 228 | 85.16% | 0.882 |
| 20-<40 % | 331 | 89.95% | 0.965 |
| 40-<60 % | 327 | 90.08% | 0.980 |
| 60-<80 % | 333 | 89.12% | 0.988 |
| 80-100 % | 332 | 87.71% | 0.993 |
| 70-100 % (High-Load) | 502 | 88.09% | 0.992 |
| All (published average) | 1551 | 88.62% | 0.967 |
Informational. Not part of the ETA or LAMBDA rating.
| Load range | Noise 230V avg (loudest) | Fan off 230V |
|---|---|---|
| 0-<20 % | 26.0 (26.0) | 0% |
| 20-<40 % | 26.0 (26.0) | 0% |
| 40-<60 % | 26.0 (27.6) | 0% |
| 60-<80 % | 33.3 (41.5) | 0% |
| 80-100 % | 42.4 (45.0) | 0% |
| 70-100 % (High-Load) | 41.0 (45.0) | 0% |
| All (published average) | 36.5 (45.0) | 0% |
Informational. Not part of the ETA or LAMBDA rating.
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 999 RPM · <6.0 dB(A) · 30.1 °C | 1023 RPM · <6.0 dB(A) · 40.1 °C | fan off in both |
| 20% | 1001 RPM · <6.0 dB(A) · 30.2 °C | 1026 RPM · <6.0 dB(A) · 40.8 °C | fan off in both |
| 50% | 1010 RPM · <6.0 dB(A) · 30.9 °C | 1109 RPM · <6.0 dB(A) · 42.5 °C | fan off in both |
| 100% | 1861 RPM · <6.0 dB(A) · 30.2 °C | 2008 RPM · <6.0 dB(A) · 45.1 °C | fan off in both |
Informational. Not part of the ETA or LAMBDA rating.