| 230V | |
| Scheme: ETA-EMI PSU | ![]() |
| 230V | |
![]() |
Scheme: LAMBDA PSU |

| Load range | Points | Efficiency 230V | PF 230V |
|---|---|---|---|
| 0-<20 % | 210 | 84.74% | 0.872 |
| 20-<40 % | 310 | 89.65% | 0.961 |
| 40-<60 % | 310 | 89.99% | 0.978 |
| 60-<80 % | 310 | 89.13% | 0.986 |
| 80-100 % | 318 | 87.73% | 0.991 |
| 70-100 % (High-Load) | 473 | 88.09% | 0.990 |
| All (published average) | 1458 | 88.48% | 0.964 |
Informational. Not part of the ETA or LAMBDA rating.
| Load range | Noise 230V avg (loudest) | Fan off 230V |
|---|---|---|
| 0-<20 % | 26.0 (26.0) | 0% |
| 20-<40 % | 26.0 (26.0) | 0% |
| 40-<60 % | 26.0 (26.0) | 0% |
| 60-<80 % | 31.0 (39.3) | 0% |
| 80-100 % | 40.3 (43.3) | 0% |
| 70-100 % (High-Load) | 39.0 (43.3) | 0% |
| All (published average) | 34.6 (43.3) | 0% |
Informational. Not part of the ETA or LAMBDA rating.
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 986 RPM · 25.4 dB(A) · 30.1 °C | 1020 RPM · 26.7 dB(A) · 40.1 °C | +1.3 dB(A) |
| 20% | 995 RPM · 25.7 dB(A) · 30.0 °C | 1026 RPM · 26.9 dB(A) · 40.8 °C | +1.2 dB(A) |
| 50% | 1005 RPM · 26.1 dB(A) · 30.8 °C | 1076 RPM · 27.8 dB(A) · 42.1 °C | +1.7 dB(A) |
| 100% | 1945 RPM · 44.7 dB(A) · 30.4 °C | 2000 RPM · 45.3 dB(A) · 45.9 °C | +0.6 dB(A) |
Informational. Not part of the ETA or LAMBDA rating.