| 230V | |
| Scheme: ETA-EMI PSU | ![]() |
| 230V | |
No LAMBDA levelAverage noise output 47.02 dB(A), above the 45 dB(A) limit of the lowest LAMBDA level (Standard). |
Scheme: LAMBDA PSU |
Outside Validation Scope

| Load range | Points | Efficiency 230V | PF 230V |
|---|---|---|---|
| 0-<20 % | 280 | 89.73% | 0.896 |
| 20-<40 % | 324 | 94.60% | 0.978 |
| 40-<60 % | 324 | 94.76% | 0.985 |
| 60-<80 % | 320 | 94.04% | 0.987 |
| 80-100 % | 327 | 92.89% | 0.990 |
| 70-100 % (High-Load) | 486 | 93.19% | 0.989 |
| All (published average) | 1575 | 93.30% | 0.969 |
Informational. Not part of the ETA or LAMBDA rating.
| Load range | Noise 230V avg (loudest) | Fan off 230V |
|---|---|---|
| 0-<20 % | 15.9 (21.9) | 64% |
| 20-<40 % | 22.5 (28.5) | 0% |
| 40-<60 % | 35.2 (41.8) | 0% |
| 60-<80 % | 46.4 (50.4) | 0% |
| 80-100 % | 53.0 (55.3) | 0% |
| 70-100 % (High-Load) | 51.9 (55.3) | 0% |
| All (published average) | 47.1 (55.3) | 11% |
Informational. Not part of the ETA or LAMBDA rating.
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 31.9 °C | 0 RPM · <6.0 dB(A) · 44.2 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 33.9 °C | 679 RPM · 23.1 dB(A) · 40.7 °C | fan starts (<6.0 → 23.1) |
| 50% | 886 RPM · 29.5 dB(A) · 30.1 °C | 1390 RPM · 41.6 dB(A) · 42.3 °C | +12.1 dB(A) |
| 100% | 1750 RPM · 47.6 dB(A) · 30.2 °C | 2399 RPM · 56.0 dB(A) · 46.0 °C | +8.4 dB(A) |
Informational. Not part of the ETA or LAMBDA rating.