CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Cooler Master MWE Gold 750 V4
Serial Number-
Lab IDCM75003436
Certification ID263436
  • Test Result Report ID: 26PS3436A
  • Certificate Issue Date: Oct 8, 2026
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
This product certification body is accredited by CYS-CYSAB (Cyprus Accreditation Body) under accreditation number C010 as a Product Certification Body, in accordance with the recognized International Standard ISO/IEC 17065:2012 “Conformity assessment — Requirements for bodies certifying products, processes and services”. The accreditation covers the ETA and LAMBDA certification of power supply units and of multimedia (information technology) equipment, and the PHI certification of cooling fans, each as a Type 1a scheme according to ISO/IEC 17067. Certifications outside that scope are not covered by the accreditation. This accreditation demonstrates technical competence for a defined scope and the operation of a management system.
Aristeidis Bitziopoulos, Certification Body General Manager
CYS-CYSAB accreditation symbol, ISO/IEC 17065:2012
No. of Accred.: C010
PRODUCT CERTIFICATION

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features(Manufacturer)

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Vampire Power

Tables

Graphs

Efficiency Graph

Efficiency and power factor by load range

828384858687888990919293Average efficiency (%)83.1588.9690.2689.9089.2985.0591.1492.6592.7492.210-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 82115V230V
828384858687888990919293Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 82115V230V
0.720.740.760.780.800.820.840.860.880.900.920.940.960.981.00Average power factor0.9330.9830.9970.9980.9990.7570.9150.9630.9800.9890-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.72115V230V
0.720.740.760.780.800.820.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.72115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %184 / 18483.15%85.05%0.9330.757
20-<40 %320 / 32088.96%91.14%0.9830.915
40-<60 %321 / 32190.26%92.65%0.9970.963
60-<80 %322 / 32289.90%92.74%0.9980.980
80-100 %330 / 32889.29%92.21%0.9990.989
70-100 % (High-Load)490 / 48889.43%92.33%0.9990.987
All (published average)1477 / 147588.80%91.30%0.9870.936

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1477 (115V) and 1475 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 750 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Noise Graph

Noise by load range

High-Load Index (70-100 % load)
Noise 30.6 dB(A) at 115V and 30.6 dB(A) at 230V · loudest point 33.3 dB(A)
Efficiency 89.43% / 92.33% · power factor 0.999 / 0.987 (115V / 230V)
0510152025303540Average noise (dB(A))8.08.00-<20 %fan off 50%/48%10.010.020-<40 %fan off 11%/12%11.712.140-<60 %fan off 0%/0%19.919.760-<80 %fan off 0%/0%32.232.280-100 %fan off 0%/0%115V230V
010203040Average noise (dB(A))8.08.00-<20 %off 50%/48%10.010.020-<40 %off 11%/12%11.712.140-<60 %off 0%/0%19.919.760-<80 %off 0%/0%32.232.280-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %8.0 (10.5)8.0 (10.5)50% / 48%
20-<40 %10.0 (10.5)10.0 (10.5)11% / 12%
40-<60 %11.7 (12.6)12.1 (12.6)0% / 0%
60-<80 %19.9 (29.2)19.7 (27.3)0% / 0%
80-100 %32.2 (33.3)32.2 (33.3)0% / 0%
70-100 % (High-Load)30.6 (33.3)30.6 (33.3)0% / 0%
All (published average)26.0 (33.3)26.0 (33.3)9% / 9%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1477 (115V) and 1475 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 750 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature".

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 40.4 °C598 RPM · 6.9 dB(A) · 40.0 °Cfan starts (<6.0 → 6.9)
20%0 RPM · <6.0 dB(A) · 35.4 °C594 RPM · 6.9 dB(A) · 41.0 °Cfan starts (<6.0 → 6.9)
50%786 RPM · 12.8 dB(A) · 30.2 °C907 RPM · 16.5 dB(A) · 42.7 °C+3.7 dB(A)
100%1535 RPM · 33.1 dB(A) · 30.3 °C2146 RPM · 42.8 dB(A) · 45.0 °C+9.7 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 39.0 °C777 RPM · 11.5 dB(A) · 40.5 °Cfan starts (<6.0 → 11.5)
20%0 RPM · <6.0 dB(A) · 38.7 °C777 RPM · 11.5 dB(A) · 41.0 °Cfan starts (<6.0 → 11.5)
50%784 RPM · 12.8 dB(A) · 30.5 °C906 RPM · 16.5 dB(A) · 42.2 °C+3.7 dB(A)
100%1530 RPM · 33.1 dB(A) · 30.8 °C2140 RPM · 42.3 dB(A) · 45.3 °C+9.2 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter, with the fan stopped; with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

Cooler Master MWE Gold 750 V4

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics runs voluntary certification programs for power supplies - ETA for efficiency, LAMBDA for noise and SAFE for safety and correct operation - and for cooling products, with DELTA for chassis soundproofing and PHI for fan airflow and static pressure. THETA rates cooler performance on AMD AM5 and Intel LGA1851 outside ISO 17065 and accreditation scope
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus