| Average Efficiency (>1450 load combinations) | 91.096% |
| Average Noise Output (>1450 Load Combinations) | 15.70dBA |
| Average PF (>1450 Load Combinations) | 0.945 |
| Efficiency With 10W (≤500W) or 2% (>500W) Load | 68.794% |
| Standby Power Consumption | 0.0714W |
| 12V Ripple (Full Load) | 59.25mV |
| 5V Ripple (Full Load) | 34.64mV |
| 3.3V Ripple (Full Load) | 30.95mV |
| 5VSB Ripple (Full Load) | 28.85mV |
| 12V Load Regulation | 1.00% |
| 5V Load Regulation | 0.52% |
| 3.3V Load Regulation | 1.37% |
| 5VSB Load Regulation | 4.63% |
| Inrush Current | 80.690A |
| 12V Transient Response (200%) | 11.34V |
| 5V Transient Response (200%) | 4.915V |
| 3.3V Transient Response (200%) | 3.139V |
| 5VSB Transient Response (200%) | 4.960V |
| Hold-Up Time & PWR_OK Signal | 19.90ms |
| AC Loss to PWR_OK Hold Up Time | 16.80ms |
| PWR_OK Inactive to DC Loss Delay | 3.10ms |
| PSU Timings: T1 (20% / 100%) | 110.0ms | 109.0ms |
| PSU Timings: T3 (20% / 100%) | 130.0ms | 129.0ms |
| 12V OCP (29.0°C / 42.2°C) | 77.300A (123.68%), 11.992V — shut down | 76.900A (123.04%), 11.988V — shut down |
| 5V OCP (29.0°C / 42.2°C) | 29.000A (145.00%), 4.991V — shut down | 28.000A (140.00%), 4.988V — shut down |
| 3.3V OCP (29.0°C / 42.2°C) | 28.600A (143.00%), 3.287V — shut down | 27.700A (138.50%), 3.293V — shut down |
| 5VSB OCP (29.0°C / 42.2°C) | 4.900A (163.33%), 4.892V — shut down | 4.800A (160.00%), 4.884V — shut down |
| OPP (28.65°C / 42.88°C) | 122.95% | 120.93% |