| Average Efficiency (>1450 load combinations) | 91.690% |
| Average Noise Output (>1450 Load Combinations) | 20.64dBA |
| Average PF (>1450 Load Combinations) | 0.959 |
| Efficiency With 10W (≤500W) or 2% (>500W) Load | 72.072% |
| Standby Power Consumption | 0.1088W |
| 12V Ripple (Full Load) | 36.35mV |
| 5V Ripple (Full Load) | 19.32mV |
| 3.3V Ripple (Full Load) | 23.99mV |
| 5VSB Ripple (Full Load) | 17.55mV |
| 12V Load Regulation | 0.61% |
| 5V Load Regulation | 0.60% |
| 3.3V Load Regulation | 1.09% |
| 5VSB Load Regulation | 3.77% |
| Inrush Current | 58.580A |
| 12V Transient Response (200%) | 11.21V |
| 5V Transient Response (200%) | 4.928V |
| 3.3V Transient Response (200%) | 3.178V |
| 5VSB Transient Response (200%) | 4.965V |
| Hold-Up Time & PWR_OK Signal | 19.30ms |
| AC Loss to PWR_OK Hold Up Time | 17.50ms |
| PWR_OK Inactive to DC Loss Delay | 1.80ms |
| PSU Timings: T1 (20% / 100%) | 100.0ms | 99.0ms |
| PSU Timings: T3 (20% / 100%) | 132.0ms | 131.0ms |
| 12V OCP (27.0°C / 42.8°C) | 114.100A (136.97%), 11.993V — shut down | 111.400A (133.73%), 11.981V — shut down |
| 5V OCP (27.0°C / 42.8°C) | 26.200A (131.00%), 5.009V — shut down | 28.100A (140.50%), 5.006V — shut down |
| 3.3V OCP (27.0°C / 42.8°C) | 27.400A (137.00%), 3.313V — shut down | 28.300A (141.50%), 3.311V — shut down |
| 5VSB OCP (27.0°C / 42.8°C) | 3.900A (130.00%), 4.952V — shut down | 3.900A (130.00%), 4.951V — shut down |
| OPP (29.52°C / 41.70°C) | 134.30% | 127.10% |