| 230V | |
| Scheme: ETA-EMI PSU | ![]() |
| 230V | |
![]() |
Scheme: LAMBDA PSU |
Outside Validation Scope

| Load range | Points | Efficiency 230V | PF 230V |
|---|---|---|---|
| 0-<20 % | 218 | 84.60% | 0.875 |
| 20-<40 % | 342 | 89.74% | 0.943 |
| 40-<60 % | 342 | 89.66% | 0.958 |
| 60-<80 % | 344 | 88.68% | 0.967 |
| 80-100 % | 352 | 87.06% | 0.971 |
| 70-100 % (High-Load) | 521 | 87.48% | 0.970 |
| All (published average) | 1598 | 88.20% | 0.948 |
Informational. Not part of the ETA or LAMBDA rating.
| Load range | Noise 230V avg (loudest) | Fan off 230V |
|---|---|---|
| 0-<20 % | 15.7 (15.7) | 0% |
| 20-<40 % | 17.6 (34.1) | 0% |
| 40-<60 % | 38.0 (41.1) | 0% |
| 60-<80 % | 41.1 (41.1) | 0% |
| 80-100 % | 41.1 (41.1) | 0% |
| 70-100 % (High-Load) | 41.1 (41.1) | 0% |
| All (published average) | 38.4 (41.1) | 0% |
Informational. Not part of the ETA or LAMBDA rating.
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 627 RPM · 14.6 dB(A) · 30.6 °C | 658 RPM · 15.3 dB(A) · 34.1 °C | +0.7 dB(A) |
| 20% | 627 RPM · 14.6 dB(A) · 30.3 °C | 658 RPM · 15.3 dB(A) · 34.6 °C | +0.7 dB(A) |
| 50% | 628 RPM · 14.6 dB(A) · 30.3 °C | 1673 RPM · 39.9 dB(A) · 36.1 °C | +25.3 dB(A) |
| 100% | 1705 RPM · 40.8 dB(A) · 30.6 °C | 1758 RPM · 41.1 dB(A) · 39.5 °C | +0.3 dB(A) |
Informational. Not part of the ETA or LAMBDA rating.