Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
ATX connector 20+4 pin (600mm)
1
1
18-22AWG
4+4 pin EPS12V (650mm)
1
1
18AWG
6+2 pin PCIe (550mm+100mm)
2
4
18AWG
SATA (400mm+110mm+110mm+110mm)
1
4
18AWG
SATA (300mm+120mm)
1
2
18AWG
4 pin Molex (400mm+120mm+120mm)
1
3
18AWG
4 pin Molex (300mm+120mm)
1
2
18AWG
FDD Adapter (+105mm)
1
1
22AWG
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary 115V
效率評比
PLATINUM
噪音評比
A++
Average Efficiency (>1450 load combinations)
90.772%
Average Noise Output (>1450 Load Combinations)
6.00dBA
Average PF (>1450 Load Combinations)
0.987
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1163W
12V Ripple (Full Load)
28.74mV
5V Ripple (Full Load)
16.49mV
3.3V Ripple (Full Load)
11.58mV
5VSB Ripple (Full Load)
7.40mV
12V Load Regulation
1.07%
5V Load Regulation
0.42%
3.3V Load Regulation
0.80%
5VSB Load Regulation
2.53%
Inrush Current
19.030A
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
19.8
AC Loss to PWR_OK Hold Up Time (ms)
16.6
PWR_OK Inactive to DC Loss Delay (ms)
3.2
待機電源消耗
Tables 115V
Graphs 115V
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO