SATA (450mm) / 4-pin Molex (+120mm+120mm) / FDD (+120mm)
1
1 / 2 / 1
18-20AWG
No
AC Power Cord (1380mm) - C13 coupler
1
1
18AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-30 / 82.4-86
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Efficiency Rating
BRONZE
Noise Rating
A-
Average Efficiency (>1450 load combinations)
82.826%
Average Noise Output (>1450 Load Combinations)
29.11dBA
Average PF (>1450 Load Combinations)
0.991
Efficiency With 10W (≤500W) or 2% (>500W) Load
53.965%
Standby Power Consumption
0.0446W
12V Ripple (Full Load)
34.64mV
5V Ripple (Full Load)
21.77mV
3.3V Ripple (Full Load)
26.97mV
5VSB Ripple (Full Load)
25.13mV
12V Load Regulation
1.88%
5V Load Regulation
1.66%
3.3V Load Regulation
2.70%
5VSB Load Regulation
3.43%
Inrush Current
17.384A
Efficiency Rating
BRONZE
Noise Rating
A-
Average Efficiency (>1450 load combinations)
85.204%
Average Noise Output (>1450 Load Combinations)
29.81dBA
Average PF (>1450 Load Combinations)
0.963
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1029W
12V Ripple (Full Load)
38.19mV
5V Ripple (Full Load)
22.52mV
3.3V Ripple (Full Load)
26.53mV
5VSB Ripple (Full Load)
25.38mV
12V Load Regulation
1.88%
5V Load Regulation
1.74%
3.3V Load Regulation
2.61%
5VSB Load Regulation
3.40%
Inrush Current
48.209A
Hold-Up Time & Power Ok Signal
13.00ms
AC Loss to PWR_OK Hold Up Time
10.40ms
PWR_OK Inactive to DC Loss Delay
2.60ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
0.00%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
13
AC Loss to PWR_OK Hold Up Time (ms)
10.4
PWR_OK Inactive to DC Loss Delay (ms)
2.6
Vampire Power
Tables
Graphs
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.225
73.052%
0.038
5.018V
0.308
115.02V
2
0.090A
0.451
77.625%
0.070
5.017V
0.581
115.03V
3
0.550A
2.754
80.739%
0.276
5.008V
3.411
115.02V
4
1.000A
4.999
81.034%
0.351
4.998V
6.169
115.02V
5
1.500A
7.483
80.575%
0.392
4.989V
9.287
115.02V
6
3.000A
14.875
76.925%
0.451
4.958V
19.337
115.02V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.225
62.155%
0.013
5.017V
0.362
230.12V
2
0.090A
0.451
69.814%
0.024
5.016V
0.646
230.12V
3
0.550A
2.754
77.709%
0.120
5.008V
3.544
230.12V
4
1.000A
4.999
79.589%
0.189
4.999V
6.281
230.12V
5
1.500A
7.477
79.543%
0.244
4.985V
9.400
230.12V
6
3.000A
14.866
79.319%
0.331
4.956V
18.742
230.13V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.698A
1.987A
1.957A
1.004A
54.406
78.311%
701
16.7
34.91°C
0.974
12.161V
5.032V
3.370V
4.981V
69.474
38.77°C
115.12V
2
6.458A
2.988A
2.942A
1.209A
109.320
83.768%
724
16.9
35.16°C
0.985
12.144V
5.022V
3.360V
4.965V
130.504
39.52°C
115.11V
3
10.638A
3.486A
3.431A
1.414A
164.828
85.298%
782
18.7
35.55°C
0.986
12.110V
5.020V
3.352V
4.952V
193.238
41.00°C
115.11V
4
14.778A
3.987A
3.947A
1.621A
219.693
85.574%
915
22.7
35.80°C
0.989
12.078V
5.018V
3.343V
4.937V
256.729
41.98°C
115.11V
5
18.579A
4.993A
4.948A
1.829A
274.567
85.263%
1037
25.8
36.17°C
0.993
12.060V
5.008V
3.334V
4.923V
322.025
43.39°C
115.13V
6
22.392A
6.004A
5.957A
2.038A
329.410
84.698%
1166
28.9
36.49°C
0.994
12.040V
4.997V
3.325V
4.907V
388.924
44.61°C
115.12V
7
26.256A
7.016A
6.967A
2.249A
384.682
83.945%
1302
32.5
37.29°C
0.996
12.020V
4.988V
3.314V
4.891V
458.255
45.93°C
115.11V
8
30.133A
8.034A
7.988A
2.463A
439.963
83.023%
1452
34.6
37.84°C
0.996
11.999V
4.979V
3.304V
4.873V
529.929
47.46°C
115.10V
9
34.432A
8.534A
8.496A
2.469A
494.474
82.003%
1605
37.4
38.78°C
0.996
11.965V
4.980V
3.295V
4.861V
602.992
49.23°C
115.10V
10
38.551A
9.038A
9.040A
3.103A
549.675
80.743%
1763
40.0
39.65°C
0.997
11.932V
4.978V
3.284V
4.836V
680.772
51.32°C
115.09V
11
43.330A
9.022A
9.063A
3.109A
604.887
79.540%
1886
42.6
40.52°C
0.997
11.890V
4.987V
3.277V
4.825V
760.477
52.70°C
115.09V
CL1
0.130A
14.000A
13.998A
0.000A
112.135
76.766%
1265
31.6
36.34°C
0.985
12.512V
4.564V
3.330V
4.946V
146.074
43.60°C
115.09V
CL2
43.979A
1.000A
0.998A
1.000A
529.738
81.300%
1688
39.3
39.94°C
0.997
11.740V
5.205V
3.312V
4.913V
651.585
51.46°C
115.09V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.673A
1.984A
1.954A
1.004A
54.081
79.751%
699
16.6
34.45°C
0.855
12.162V
5.033V
3.370V
4.982V
67.812
37.95°C
230.12V
2
6.433A
2.983A
2.942A
1.208A
108.999
85.377%
726
16.9
35.01°C
0.929
12.145V
5.023V
3.361V
4.966V
127.668
38.82°C
230.13V
3
10.613A
3.481A
3.427A
1.413A
164.503
87.159%
835
20.6
35.41°C
0.949
12.111V
5.022V
3.352V
4.954V
188.739
39.58°C
230.13V
4
14.747A
3.982A
3.944A
1.620A
219.324
87.681%
920
22.8
35.72°C
0.964
12.080V
5.020V
3.344V
4.939V
250.138
40.28°C
230.13V
5
18.553A
4.987A
4.944A
1.828A
274.237
87.598%
1082
27.5
36.64°C
0.974
12.061V
5.010V
3.334V
4.924V
313.062
41.64°C
230.14V
6
22.370A
6.001A
5.950A
2.038A
329.159
87.262%
1227
30.3
37.47°C
0.978
12.042V
4.998V
3.325V
4.908V
377.207
42.83°C
230.14V
7
26.221A
7.020A
6.966A
2.249A
384.452
86.757%
1309
32.6
37.65°C
0.980
12.027V
4.984V
3.316V
4.893V
443.135
43.50°C
230.15V
8
30.117A
8.032A
7.984A
2.463A
439.785
86.081%
1481
35.3
38.36°C
0.984
12.000V
4.979V
3.305V
4.873V
510.899
45.16°C
230.15V
9
34.413A
8.535A
8.490A
2.468A
494.327
85.377%
1639
37.9
39.20°C
0.984
11.968V
4.978V
3.296V
4.863V
578.996
46.43°C
230.16V
10
38.537A
9.037A
9.036A
3.102A
549.541
84.539%
1760
40.0
39.48°C
0.986
11.933V
4.979V
3.285V
4.836V
650.046
47.27°C
230.16V
11
43.313A
9.023A
9.059A
3.108A
604.773
83.702%
1883
42.5
40.55°C
0.987
11.892V
4.987V
3.278V
4.827V
722.528
48.88°C
230.15V
CL1
0.117A
13.999A
13.998A
0.000A
112.023
78.255%
1263
31.5
36.62°C
0.939
12.508V
4.569V
3.329V
4.944V
143.152
41.81°C
230.15V
CL2
43.956A
1.000A
0.997A
1.000A
529.725
84.949%
1658
38.1
39.35°C
0.987
11.746V
5.201V
3.313V
4.914V
623.578
47.11°C
230.16V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.181A
0.493A
0.471A
0.200A
19.448
65.070%
646
15.2
0.935
12.153V
5.073V
3.379V
5.008V
29.888
115.11V
2
2.437A
0.988A
0.975A
0.400A
39.899
75.606%
664
15.2
0.967
12.149V
5.062V
3.375V
5.000V
52.772
115.11V
3
3.622A
1.486A
1.451A
0.601A
59.397
79.834%
680
15.9
0.975
12.148V
5.051V
3.371V
4.991V
74.401
115.11V
4
4.873A
1.984A
1.959A
0.803A
79.780
82.186%
696
16.6
0.985
12.145V
5.041V
3.367V
4.982V
97.073
115.11V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.158A
0.490A
0.469A
0.200A
19.146
66.853%
661
15.2
0.653
12.152V
5.075V
3.379V
5.008V
28.639
230.12V
2
2.413A
0.985A
0.973A
0.400A
39.587
77.195%
668
15.2
0.802
12.149V
5.062V
3.375V
5.001V
51.282
230.12V
3
3.599A
1.482A
1.446A
0.601A
59.086
81.392%
682
15.9
0.867
12.149V
5.052V
3.371V
4.992V
72.594
230.12V
4
4.849A
1.979A
1.956A
0.803A
79.461
83.717%
694
16.5
0.901
12.146V
5.042V
3.367V
4.983V
94.916
230.12V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.2 mV
7.5 mV
11.6 mV
14.2 mV
Pass
20% Load
6.3 mV
8.4 mV
12.9 mV
15.9 mV
Pass
30% Load
8.1 mV
10.2 mV
12.7 mV
18.1 mV
Pass
40% Load
17.1 mV
9.9 mV
40.4 mV
17.4 mV
Pass
50% Load
12.7 mV
9.8 mV
14.9 mV
17.6 mV
Pass
60% Load
14.3 mV
11.3 mV
16.0 mV
18.4 mV
Pass
70% Load
17.3 mV
12.0 mV
17.5 mV
17.7 mV
Pass
80% Load
20.1 mV
12.8 mV
21.4 mV
22.3 mV
Pass
90% Load
22.9 mV
13.9 mV
23.9 mV
23.4 mV
Pass
100% Load
34.6 mV
21.8 mV
27.0 mV
25.1 mV
Pass
110% Load
40.1 mV
25.7 mV
29.0 mV
28.0 mV
Pass
Crossload 1
10.7 mV
31.4 mV
22.0 mV
14.0 mV
Pass
Crossload 2
38.0 mV
28.4 mV
22.3 mV
18.2 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.3 mV
8.0 mV
13.6 mV
13.1 mV
Pass
20% Load
8.5 mV
8.3 mV
13.2 mV
15.2 mV
Pass
30% Load
9.3 mV
10.1 mV
14.6 mV
16.2 mV
Pass
40% Load
11.2 mV
8.8 mV
17.4 mV
18.5 mV
Pass
50% Load
13.7 mV
9.0 mV
15.4 mV
18.0 mV
Pass
60% Load
16.4 mV
11.6 mV
17.0 mV
17.9 mV
Pass
70% Load
18.5 mV
11.6 mV
17.7 mV
17.7 mV
Pass
80% Load
22.1 mV
13.2 mV
21.5 mV
21.2 mV
Pass
90% Load
24.9 mV
14.4 mV
39.6 mV
41.0 mV
Pass
100% Load
38.2 mV
22.5 mV
26.5 mV
25.4 mV
Pass
110% Load
46.3 mV
27.7 mV
28.8 mV
24.5 mV
Pass
Crossload 1
11.5 mV
33.4 mV
22.2 mV
13.2 mV
Pass
Crossload 2
39.8 mV
29.0 mV
20.3 mV
17.2 mV
Pass
The results above are not used in the certification process
Corsair VS550
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted