Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (360mm)
1
1
18AWG
No
4+4 pin EPS12V (400mm)
1
1
18AWG
No
6+2 pin PCIe (400mm+100mm)
1
2
18AWG
No
SATA (300mm+200mm+100mm)
1
3
18AWG
No
4 pin Molex (300mm+200mm+200mm)
1
3
18AWG
No
AC Power Cord (1370mm) - C13 coupler
1
1
18AWG
-
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
20
20
41
3
0.3
Watts
100
492
15
3.6
Total Max. Power (W)
500
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
88.907%
Average Noise Output (>1450 Load Combinations)
31.11dBA
Average PF (>1450 Load Combinations)
0.981
Efficiency With 10W (≤500W) or 2% (>500W) Load
60.452%
Standby Power Consumption
0.0444W
Non-Accredited
12V Ripple (Full Load)
26.33mV
5V Ripple (Full Load)
23.73mV
3.3V Ripple (Full Load)
23.88mV
5VSB Ripple (Full Load)
14.62mV
12V Load Regulation
0.08%
5V Load Regulation
0.34%
3.3V Load Regulation
0.42%
5VSB Load Regulation
2.00%
Inrush Current
39.069A
Accredited
Average Efficiency (>1450 load combinations)
90.840%
Average Noise Output (>1450 Load Combinations)
29.07dBA
Average PF (>1450 Load Combinations)
0.927
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.0678W
Non-Accredited
12V Ripple (Full Load)
26.79mV
5V Ripple (Full Load)
24.23mV
3.3V Ripple (Full Load)
22.88mV
5VSB Ripple (Full Load)
12.98mV
12V Load Regulation
0.07%
5V Load Regulation
0.32%
3.3V Load Regulation
0.42%
5VSB Load Regulation
1.94%
Inrush Current
56.094A
Hold-Up Time & PWR_OK Signal
23.50ms
AC Loss to PWR_OK Hold Up Time
21.10ms
PWR_OK Inactive to DC Loss Delay
2.40ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
23.5
AC Loss to PWR_OK Hold Up Time (ms)
21.1
PWR_OK Inactive to DC Loss Delay (ms)
2.4
Stromverbrauch im Ruhezustand
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232
68.843%
0.055
5.152V
0.337
115.09V
2
0.090A
0.464
73.418%
0.100
5.151V
0.632
115.09V
3
0.550A
2.829
77.528%
0.335
5.143V
3.649
115.09V
4
1.000A
5.136
77.560%
0.403
5.136V
6.622
115.09V
5
1.500A
7.692
77.799%
0.437
5.127V
9.887
115.09V
6
3.000A
15.290
76.032%
0.481
5.096V
20.110
115.08V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232
62.534%
0.018
5.152V
0.371
230.26V
2
0.090A
0.464
68.945%
0.033
5.151V
0.673
230.26V
3
0.550A
2.829
76.171%
0.161
5.142V
3.714
230.24V
4
1.000A
5.136
77.013%
0.242
5.135V
6.669
230.24V
5
1.500A
7.690
76.977%
0.297
5.126V
9.990
230.25V
6
3.001A
15.306
78.044%
0.371
5.101V
19.612
230.25V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.333A
2.000A
1.984A
0.975A
49.518
83.324%
0
<6.0
43.89°C
0.934
11.973V
4.999V
3.320V
5.128V
59.428
39.40°C
115.09V
2
5.739A
3.002A
2.980A
1.172A
99.611
88.256%
0
<6.0
44.38°C
0.972
11.975V
4.996V
3.318V
5.119V
112.866
39.75°C
115.09V
3
9.480A
3.503A
3.465A
1.370A
149.523
89.764%
0
<6.0
45.16°C
0.981
11.976V
4.995V
3.317V
5.110V
166.574
40.07°C
115.08V
4
13.223A
4.004A
3.980A
1.568A
199.550
89.821%
939
19.8
40.60°C
0.985
11.976V
4.994V
3.316V
5.101V
222.163
45.94°C
115.09V
5
16.630A
5.007A
4.976A
1.768A
249.682
89.851%
1014
23.2
41.18°C
0.988
11.977V
4.994V
3.315V
5.093V
277.886
46.78°C
115.09V
6
20.034A
6.007A
5.973A
1.967A
299.761
89.414%
1338
33.2
41.95°C
0.987
11.978V
4.993V
3.315V
5.084V
335.249
47.87°C
115.09V
7
23.441A
7.010A
6.969A
2.168A
349.889
88.914%
1489
36.7
42.31°C
0.988
11.979V
4.992V
3.314V
5.074V
393.514
48.36°C
115.09V
8
26.851A
8.016A
7.966A
2.370A
400.017
88.317%
1797
41.5
42.71°C
0.989
11.978V
4.990V
3.313V
5.065V
452.931
48.86°C
115.09V
9
30.657A
8.523A
8.452A
2.373A
449.759
87.826%
2028
44.1
43.11°C
0.990
11.979V
4.989V
3.312V
5.059V
512.105
49.77°C
115.12V
10
34.231A
9.024A
8.971A
2.975A
499.788
87.232%
2082
44.1
44.26°C
0.991
11.980V
4.987V
3.310V
5.043V
572.942
51.03°C
115.13V
11
38.404A
9.027A
8.971A
2.978A
549.815
86.720%
2084
44.1
46.09°C
0.992
11.981V
4.986V
3.309V
5.038V
634.013
53.27°C
115.12V
CL1
0.140A
12.000A
11.998A
0.000A
101.367
83.622%
1245
31.4
41.74°C
0.973
11.977V
4.995V
3.313V
5.124V
121.220
46.13°C
115.18V
CL2
41.008A
1.004A
0.997A
1.000A
504.765
88.169%
2089
44.1
44.76°C
0.991
11.982V
4.992V
3.317V
5.088V
572.496
51.15°C
115.10V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.340A
2.000A
1.985A
0.975A
49.602
84.250%
0
<6.0
45.02°C
0.712
11.972V
4.999V
3.320V
5.127V
58.875
39.46°C
230.26V
2
5.745A
3.002A
2.982A
1.173A
99.691
89.362%
0
<6.0
45.34°C
0.856
11.975V
4.996V
3.318V
5.117V
111.559
39.59°C
230.27V
3
9.489A
3.503A
3.465A
1.370A
149.621
90.559%
935
19.7
40.45°C
0.907
11.975V
4.995V
3.317V
5.109V
165.219
46.43°C
230.28V
4
13.231A
4.005A
3.981A
1.569A
199.644
91.417%
941
19.9
40.85°C
0.934
11.975V
4.994V
3.316V
5.100V
218.388
46.93°C
230.28V
5
16.640A
5.007A
4.977A
1.768A
249.769
91.666%
1010
23.2
41.38°C
0.948
11.975V
4.994V
3.315V
5.092V
272.476
47.77°C
230.29V
6
20.042A
6.010A
5.973A
1.968A
299.844
91.419%
1375
33.2
41.89°C
0.958
11.977V
4.992V
3.314V
5.083V
327.988
48.39°C
230.29V
7
23.450A
7.013A
6.970A
2.169A
349.993
91.100%
1624
41.8
42.05°C
0.964
11.978V
4.992V
3.314V
5.072V
384.184
49.17°C
230.30V
8
26.857A
8.015A
7.969A
2.370A
400.091
90.837%
1846
42.3
42.74°C
0.969
11.978V
4.990V
3.313V
5.064V
440.449
49.90°C
230.30V
9
30.665A
8.520A
8.454A
2.373A
449.805
90.598%
2039
44.2
43.80°C
0.972
11.978V
4.989V
3.311V
5.058V
496.483
51.26°C
230.31V
10
34.239A
9.023A
8.972A
2.975A
499.846
90.273%
2078
45.4
44.20°C
0.975
11.979V
4.987V
3.310V
5.043V
553.705
52.40°C
230.31V
11
38.412A
9.027A
8.974A
2.978A
549.873
90.045%
2084
44.1
46.25°C
0.977
11.980V
4.985V
3.309V
5.038V
610.667
54.73°C
230.32V
CL1
0.144A
11.999A
12.001A
0.000A
101.419
84.659%
1277
30.1
41.70°C
0.866
11.976V
4.995V
3.313V
5.123V
119.797
47.97°C
230.32V
CL2
41.014A
1.003A
0.999A
1.000A
504.797
91.227%
2081
44.1
44.03°C
0.975
11.981V
4.992V
3.317V
5.088V
553.344
52.42°C
230.32V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.194A
0.499A
0.477A
0.194A
19.373
73.341%
0
<6.0
0.816
11.967V
5.008V
3.326V
5.146V
26.415
115.08V
2
2.466A
0.997A
0.989A
0.389A
39.796
82.532%
0
<6.0
0.919
11.971V
5.004V
3.324V
5.140V
48.219
115.08V
3
3.668A
1.499A
1.471A
0.584A
59.298
86.131%
0
<6.0
0.949
11.973V
5.001V
3.321V
5.135V
68.846
115.08V
4
4.936A
2.000A
1.987A
0.780A
79.698
87.354%
0
<6.0
0.962
11.974V
4.999V
3.320V
5.129V
91.236
115.08V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
2.882A
0.501A
0.477A
0.195A
39.578
83.708%
0
<6.0
0.654
11.964V
5.007V
3.326V
5.143V
47.281
230.25V
2
4.149A
1.000A
0.990A
0.389A
59.961
87.164%
0
<6.0
0.749
11.971V
5.003V
3.324V
5.137V
68.791
230.25V
3
5.348A
1.499A
1.474A
0.585A
79.419
88.852%
0
<6.0
0.813
11.972V
5.000V
3.321V
5.132V
89.383
230.24V
4
6.615A
2.000A
1.986A
0.780A
99.793
89.979%
0
<6.0
0.855
11.974V
4.998V
3.319V
5.126V
110.907
230.24V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
11.8 mV
9.2 mV
14.2 mV
9.8 mV
Pass
20% Load
13.5 mV
10.8 mV
15.1 mV
10.1 mV
Pass
30% Load
12.5 mV
11.9 mV
15.7 mV
10.4 mV
Pass
40% Load
12.6 mV
12.8 mV
16.0 mV
10.4 mV
Pass
50% Load
13.4 mV
14.7 mV
16.8 mV
10.7 mV
Pass
60% Load
14.8 mV
16.5 mV
17.8 mV
11.2 mV
Pass
70% Load
15.7 mV
17.7 mV
19.1 mV
11.6 mV
Pass
80% Load
17.1 mV
20.8 mV
21.6 mV
12.6 mV
Pass
90% Load
17.8 mV
22.7 mV
23.4 mV
12.8 mV
Pass
100% Load
26.3 mV
23.7 mV
23.9 mV
14.6 mV
Pass
110% Load
27.4 mV
24.7 mV
24.8 mV
15.6 mV
Pass
Crossload 1
22.0 mV
21.9 mV
23.2 mV
10.2 mV
Pass
Crossload 2
24.8 mV
14.5 mV
17.7 mV
13.4 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
10.9 mV
9.0 mV
14.7 mV
9.2 mV
Pass
20% Load
12.7 mV
10.5 mV
16.3 mV
9.4 mV
Pass
30% Load
11.7 mV
11.3 mV
15.4 mV
10.1 mV
Pass
40% Load
12.3 mV
12.3 mV
17.1 mV
10.7 mV
Pass
50% Load
12.8 mV
14.4 mV
16.9 mV
10.6 mV
Pass
60% Load
13.4 mV
15.8 mV
18.6 mV
11.4 mV
Pass
70% Load
14.6 mV
18.0 mV
44.5 mV
28.1 mV
Pass
80% Load
16.1 mV
20.7 mV
22.0 mV
11.6 mV
Pass
90% Load
16.9 mV
21.4 mV
22.8 mV
11.9 mV
Pass
100% Load
26.8 mV
24.2 mV
22.9 mV
13.0 mV
Pass
110% Load
27.6 mV
24.7 mV
24.1 mV
13.6 mV
Pass
Crossload 1
20.9 mV
21.2 mV
22.7 mV
10.1 mV
Pass
Crossload 2
24.8 mV
14.3 mV
17.9 mV
12.5 mV
Pass
The results above are not used in the certification process