This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.228
70.588%
0.032
5.065V
0.323
115.14V
2
0.090A
0.456
74.877%
0.060
5.065V
0.609
115.14V
3
0.550A
2.780
78.620%
0.257
5.053V
3.536
115.13V
4
1.000A
5.042
77.581%
0.345
5.041V
6.499
115.13V
5
1.500A
7.543
77.444%
0.393
5.029V
9.740
115.13V
6
3.000A
14.965
76.751%
0.455
4.988V
19.498
115.13V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.228
64.773%
0.011
5.064V
0.352
230.29V
2
0.090A
0.456
70.807%
0.019
5.065V
0.644
230.27V
3
0.550A
2.780
76.774%
0.101
5.053V
3.621
230.27V
4
1.000A
5.041
77.399%
0.166
5.041V
6.513
230.27V
5
1.500A
7.542
77.338%
0.222
5.028V
9.752
230.25V
6
3.000A
14.962
77.291%
0.318
4.987V
19.358
230.24V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.359A
1.982A
1.998A
0.995A
74.438
85.961%
0
<6.0
43.90°C
0.973
12.123V
5.045V
3.301V
5.024V
86.595
39.90°C
115.10V
2
9.782A
2.975A
2.999A
1.196A
149.317
89.693%
0
<6.0
44.71°C
0.988
12.106V
5.043V
3.298V
5.018V
166.476
40.43°C
115.10V
3
15.639A
3.474A
3.489A
1.397A
224.846
91.461%
0
<6.0
45.76°C
0.991
12.075V
5.040V
3.295V
5.011V
245.837
41.09°C
115.11V
4
21.441A
3.970A
4.007A
1.599A
299.665
91.199%
791
16.3
41.85°C
0.993
12.054V
5.040V
3.295V
5.005V
328.583
46.80°C
115.11V
5
26.923A
4.964A
5.012A
1.801A
374.580
90.808%
793
16.3
42.13°C
0.992
12.037V
5.037V
3.292V
4.999V
412.495
47.71°C
115.11V
6
32.418A
5.962A
6.019A
2.003A
449.507
90.188%
794
16.4
42.56°C
0.992
12.021V
5.034V
3.289V
4.993V
498.413
49.19°C
115.11V
7
37.955A
6.959A
7.024A
2.207A
524.838
89.484%
795
16.4
43.21°C
0.993
12.007V
5.032V
3.287V
4.987V
586.513
50.92°C
115.11V
8
43.490A
7.957A
8.040A
2.411A
600.167
88.626%
1131
28.4
43.80°C
0.994
11.997V
5.028V
3.284V
4.980V
677.188
52.23°C
115.11V
9
49.418A
8.460A
8.528A
2.411A
674.717
87.866%
1298
32.4
44.65°C
0.994
11.983V
5.027V
3.284V
4.980V
767.897
53.98°C
115.11V
10
55.146A
8.959A
9.051A
3.025A
749.919
86.961%
1642
39.2
45.71°C
0.995
11.972V
5.024V
3.281V
4.960V
862.367
56.27°C
115.11V
11
61.479A
8.963A
9.051A
3.027A
825.137
86.058%
1780
41.3
46.54°C
0.995
11.962V
5.022V
3.282V
4.958V
958.818
57.72°C
115.11V
CL1
0.136A
18.006A
17.998A
0.000A
151.320
82.647%
1022
25.0
42.59°C
0.989
12.099V
5.025V
3.289V
5.076V
183.092
47.81°C
115.13V
CL2
62.521A
1.004A
0.999A
1.000A
762.085
87.491%
1547
37.6
45.46°C
0.995
11.976V
5.030V
3.285V
5.001V
871.043
56.11°C
115.11V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.364A
1.981A
1.999A
0.996A
74.501
86.937%
0
<6.0
43.64°C
0.827
12.123V
5.045V
3.301V
5.023V
85.695
39.91°C
230.26V
2
9.786A
2.975A
3.000A
1.196A
149.367
90.999%
0
<6.0
44.60°C
0.929
12.106V
5.043V
3.298V
5.018V
164.142
40.46°C
230.26V
3
15.642A
3.473A
3.488A
1.397A
224.875
92.867%
0
<6.0
45.85°C
0.958
12.075V
5.040V
3.295V
5.011V
242.148
41.27°C
230.26V
4
21.432A
3.972A
4.008A
1.599A
299.649
93.059%
0
<6.0
46.79°C
0.971
12.059V
5.037V
3.292V
5.003V
322.000
41.70°C
230.25V
5
26.923A
4.965A
5.012A
1.801A
374.579
92.709%
791
16.3
42.30°C
0.978
12.037V
5.036V
3.292V
4.999V
404.039
48.26°C
230.25V
6
32.416A
5.961A
6.021A
2.004A
449.483
92.320%
794
16.4
42.73°C
0.981
12.021V
5.033V
3.289V
4.993V
486.873
49.37°C
230.25V
7
38.086A
6.959A
6.700A
2.105A
524.803
91.894%
795
16.4
43.43°C
0.983
12.006V
5.031V
3.288V
4.989V
571.097
50.82°C
230.25V
8
43.493A
7.956A
8.037A
2.410A
600.104
91.343%
1063
26.1
43.71°C
0.985
11.995V
5.028V
3.285V
4.980V
656.976
52.04°C
230.25V
9
49.414A
8.459A
8.529A
2.411A
674.648
90.840%
1298
32.4
44.53°C
0.987
11.983V
5.026V
3.283V
4.979V
742.678
53.76°C
230.25V
10
55.141A
8.959A
9.052A
3.025A
749.861
90.245%
1656
39.4
45.64°C
0.987
11.972V
5.024V
3.281V
4.960V
830.918
56.01°C
230.24V
11
61.476A
8.962A
9.058A
3.027A
825.089
89.673%
1777
41.3
46.68°C
0.988
11.962V
5.022V
3.279V
4.957V
920.107
58.01°C
230.25V
CL1
0.141A
18.004A
17.999A
0.000A
151.267
83.847%
1021
25.0
42.28°C
0.938
12.097V
5.024V
3.284V
5.075V
180.408
48.66°C
230.26V
CL2
62.509A
1.002A
1.000A
1.000A
761.806
90.778%
1474
36.3
45.72°C
0.987
11.974V
5.030V
3.282V
5.000V
839.201
56.08°C
230.25V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.194A
0.496A
0.484A
0.198A
19.483
80.246%
0
<6.0
0.818
12.048V
5.045V
3.299V
5.040V
24.279
115.11V
2
2.461A
0.989A
0.998A
0.397A
39.955
85.219%
0
<6.0
0.932
12.054V
5.047V
3.305V
5.039V
46.885
115.11V
3
3.653A
1.487A
1.481A
0.596A
59.425
86.852%
0
<6.0
0.961
12.052V
5.047V
3.304V
5.034V
68.421
115.11V
4
4.890A
1.983A
1.997A
0.795A
79.853
86.397%
0
<6.0
0.975
12.117V
5.046V
3.303V
5.030V
92.426
115.11V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.202A
0.497A
0.485A
0.199A
19.597
80.276%
0
<6.0
0.434
12.052V
5.044V
3.298V
5.040V
24.412
230.28V
2
2.469A
0.991A
0.999A
0.397A
40.068
85.639%
0
<6.0
0.652
12.056V
5.046V
3.304V
5.038V
46.787
230.28V
3
3.638A
1.487A
1.485A
0.596A
59.519
85.014%
0
<6.0
0.777
12.125V
5.046V
3.303V
5.034V
70.011
230.27V
4
4.900A
1.983A
2.000A
0.796A
79.886
87.483%
0
<6.0
0.840
12.097V
5.045V
3.302V
5.029V
91.316
230.27V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
5.9 mV
7.1 mV
9.7 mV
9.3 mV
Pass
20% Load
6.7 mV
8.0 mV
11.0 mV
9.8 mV
Pass
30% Load
10.8 mV
8.8 mV
12.3 mV
9.7 mV
Pass
40% Load
9.4 mV
9.2 mV
12.4 mV
9.9 mV
Pass
50% Load
9.7 mV
10.7 mV
13.3 mV
11.3 mV
Pass
60% Load
9.4 mV
10.6 mV
13.6 mV
10.5 mV
Pass
70% Load
10.1 mV
11.5 mV
14.0 mV
10.9 mV
Pass
80% Load
10.7 mV
12.0 mV
17.3 mV
11.2 mV
Pass
90% Load
11.7 mV
12.8 mV
20.5 mV
13.1 mV
Pass
100% Load
16.5 mV
13.8 mV
29.9 mV
12.4 mV
Pass
110% Load
16.9 mV
14.5 mV
29.7 mV
14.0 mV
Pass
Crossload 1
18.4 mV
12.2 mV
20.1 mV
12.0 mV
Pass
Crossload 2
16.2 mV
11.8 mV
19.6 mV
12.3 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.9 mV
7.4 mV
11.5 mV
10.6 mV
Pass
20% Load
6.7 mV
8.1 mV
12.7 mV
11.1 mV
Pass
30% Load
11.3 mV
9.1 mV
13.4 mV
10.7 mV
Pass
40% Load
9.7 mV
9.3 mV
13.3 mV
10.6 mV
Pass
50% Load
9.6 mV
11.2 mV
15.4 mV
11.9 mV
Pass
60% Load
9.3 mV
11.0 mV
15.0 mV
10.9 mV
Pass
70% Load
9.6 mV
11.3 mV
15.9 mV
10.9 mV
Pass
80% Load
10.4 mV
12.0 mV
16.4 mV
11.4 mV
Pass
90% Load
10.8 mV
12.9 mV
17.4 mV
12.0 mV
Pass
100% Load
15.8 mV
14.1 mV
17.9 mV
12.5 mV
Pass
110% Load
17.9 mV
14.5 mV
30.8 mV
12.0 mV
Pass
Crossload 1
21.7 mV
11.6 mV
18.1 mV
10.3 mV
Pass
Crossload 2
15.9 mV
12.1 mV
16.5 mV
11.4 mV
Pass