Power Specifications
Rail
3.3V
5V
12V(1)
12V(2)
5VSB
-12V
Max. Power
Amps
25
20
36
30
3
0.3
Watts
150
672
15
3.6
Total Max. Power (W)
700
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
87.694%
Average Noise Output (>1450 Load Combinations)
20.82dBA
Average PF (>1450 Load Combinations)
0.989
Efficiency With 10W (≤500W) or 2% (>500W) Load
59.221%
Standby Power Consumption
0.1261W
Non-Accredited
12V Ripple (Full Load)
68.66mV
5V Ripple (Full Load)
35.65mV
3.3V Ripple (Full Load)
57.03mV
5VSB Ripple (Full Load)
30.52mV
12V Load Regulation
1.00%
5V Load Regulation
2.20%
3.3V Load Regulation
2.95%
5VSB Load Regulation
2.83%
Inrush Current
98.705A
Accredited
Average Efficiency (>1450 load combinations)
89.059%
Average Noise Output (>1450 Load Combinations)
19.73dBA
Average PF (>1450 Load Combinations)
0.974
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.2031W
Non-Accredited
12V Ripple (Full Load)
59.29mV
5V Ripple (Full Load)
33.27mV
3.3V Ripple (Full Load)
49.35mV
5VSB Ripple (Full Load)
24.28mV
12V Load Regulation
0.94%
5V Load Regulation
2.14%
3.3V Load Regulation
2.64%
5VSB Load Regulation
2.83%
Inrush Current
103.159A
Hold-Up Time & PWR_OK Signal
28.40ms
AC Loss to PWR_OK Hold Up Time
30.40ms
PWR_OK Inactive to DC Loss Delay
-2.00ms
OPP (0.00°C / 0.00°C)
117.65%
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
28.4
AC Loss to PWR_OK Hold Up Time (ms)
30.4
PWR_OK Inactive to DC Loss Delay (ms)
-2
待機電源消耗
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.229
58.869%
0.075
5.087V
0.389
115.11V
2
0.090A
0.458
69.289%
0.121
5.086V
0.661
115.11V
3
0.550A
2.792
78.959%
0.328
5.075V
3.536
115.11V
4
1.000A
5.067
78.400%
0.380
5.066V
6.463
115.11V
5
1.500A
7.585
80.333%
0.406
5.056V
9.442
115.11V
6
3.000A
15.075
78.844%
0.451
5.025V
19.120
115.11V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.229
48.932%
0.028
5.086V
0.468
230.25V
2
0.090A
0.458
62.398%
0.043
5.085V
0.734
230.25V
3
0.550A
2.792
77.837%
0.174
5.075V
3.587
230.25V
4
1.000A
5.066
78.640%
0.248
5.066V
6.442
230.24V
5
1.500A
7.584
78.282%
0.294
5.055V
9.688
230.24V
6
3.000A
15.074
79.345%
0.354
5.024V
18.998
230.25V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.956A
1.981A
1.945A
0.988A
69.591
84.254%
670
11.0
39.49°C
0.949
12.133V
5.047V
3.390V
5.062V
82.597
42.81°C
115.09V
2
8.977A
2.977A
2.928A
1.188A
139.691
88.868%
671
11.0
40.17°C
0.972
12.121V
5.035V
3.379V
5.049V
157.190
43.93°C
115.10V
3
14.337A
3.482A
3.409A
1.390A
209.601
90.043%
673
11.0
41.43°C
0.984
12.109V
5.026V
3.371V
5.037V
232.779
45.49°C
115.09V
4
19.709A
3.990A
3.926A
1.592A
279.619
90.241%
674
11.0
41.72°C
0.991
12.097V
5.014V
3.361V
5.024V
309.857
46.18°C
115.09V
5
24.762A
4.998A
4.921A
1.796A
349.724
89.844%
676
10.9
42.36°C
0.994
12.084V
5.004V
3.351V
5.011V
389.255
47.82°C
115.09V
6
29.825A
6.012A
5.927A
2.001A
419.826
89.178%
678
10.9
42.64°C
0.997
12.071V
4.991V
3.341V
4.998V
470.775
49.24°C
115.09V
7
34.905A
7.035A
6.940A
2.208A
489.964
88.393%
933
17.0
43.41°C
0.998
12.057V
4.977V
3.328V
4.984V
554.304
50.69°C
115.09V
8
40.000A
8.064A
7.967A
2.415A
560.091
87.420%
1212
24.9
43.91°C
0.998
12.042V
4.961V
3.314V
4.970V
640.691
52.45°C
115.09V
9
45.499A
8.586A
8.476A
2.420A
629.825
86.449%
1454
28.9
44.80°C
0.998
12.029V
4.951V
3.304V
4.960V
728.554
54.09°C
115.09V
10
50.756A
9.107A
9.022A
3.038A
699.730
85.642%
1505
30.2
45.43°C
0.998
12.019V
4.940V
3.292V
4.939V
817.045
55.91°C
115.09V
11
56.644A
9.121A
9.035A
3.043A
769.780
84.073%
1553
31.3
46.98°C
0.998
12.006V
4.935V
3.287V
4.930V
915.610
57.94°C
115.09V
CL1
0.135A
18.004A
18.001A
0.000A
151.058
82.191%
669
11.0
42.32°C
0.978
12.105V
4.959V
3.341V
5.048V
183.788
47.74°C
115.12V
CL2
56.007A
1.001A
1.001A
1.000A
687.180
85.367%
1413
28.2
45.58°C
0.998
12.032V
4.983V
3.317V
4.996V
804.976
55.80°C
115.10V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.955A
1.986A
1.956A
0.988A
69.567
82.890%
668
11.0
39.50°C
0.895
12.130V
5.034V
3.372V
5.061V
83.927
42.71°C
230.22V
2
8.977A
2.986A
2.941A
1.188A
139.673
88.676%
668
11.0
40.24°C
0.946
12.118V
5.023V
3.363V
5.050V
157.509
43.82°C
230.22V
3
14.340A
3.492A
3.427A
1.390A
209.602
90.548%
670
11.0
41.00°C
0.965
12.106V
5.013V
3.354V
5.038V
231.482
45.31°C
230.23V
4
19.712A
3.997A
3.945A
1.592A
279.603
91.185%
671
11.0
41.68°C
0.976
12.094V
5.004V
3.347V
5.026V
306.633
46.41°C
230.23V
5
24.767A
5.007A
4.943A
1.796A
349.714
91.310%
673
11.0
42.35°C
0.982
12.081V
4.994V
3.338V
5.011V
382.996
47.89°C
230.23V
6
29.830A
6.023A
5.950A
2.002A
419.818
91.062%
674
11.0
42.65°C
0.986
12.069V
4.980V
3.328V
4.997V
461.024
49.09°C
230.23V
7
34.921A
7.051A
6.966A
2.209A
490.058
90.537%
938
16.9
43.38°C
0.990
12.054V
4.966V
3.316V
4.982V
541.281
51.12°C
230.27V
8
40.006A
8.077A
7.988A
2.417A
560.179
89.980%
1218
24.8
43.73°C
0.991
12.042V
4.954V
3.306V
4.967V
622.559
52.40°C
230.28V
9
45.500A
8.602A
8.495A
2.421A
629.887
89.365%
1460
28.9
44.63°C
0.992
12.030V
4.943V
3.296V
4.958V
704.851
53.85°C
230.28V
10
50.748A
9.126A
9.039A
3.039A
699.757
88.791%
1510
30.3
45.98°C
0.993
12.021V
4.932V
3.286V
4.937V
788.097
56.39°C
230.27V
11
56.616A
9.136A
9.055A
3.043A
769.668
88.325%
1562
31.4
46.70°C
0.994
12.010V
4.926V
3.280V
4.931V
871.401
57.91°C
230.24V
CL1
0.131A
18.002A
17.999A
0.000A
150.452
82.577%
674
11.0
42.28°C
0.954
12.100V
4.945V
3.325V
5.047V
182.197
47.94°C
230.25V
CL2
55.995A
1.002A
1.000A
1.000A
687.014
88.910%
1415
28.2
45.85°C
0.993
12.032V
4.972V
3.305V
4.995V
772.704
56.52°C
230.24V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.181A
0.494A
0.468A
0.197A
19.432
66.151%
667
11.0
0.890
12.145V
5.055V
3.397V
5.083V
29.375
115.09V
2
2.437A
0.989A
0.969A
0.394A
39.868
78.599%
668
11.0
0.928
12.140V
5.051V
3.392V
5.076V
50.723
115.09V
3
3.621A
1.484A
1.444A
0.592A
59.335
83.354%
669
11.0
0.941
12.136V
5.049V
3.391V
5.070V
71.184
115.09V
4
4.878A
1.979A
1.946A
0.790A
79.762
85.671%
669
11.0
0.954
12.130V
5.049V
3.391V
5.065V
93.103
115.09V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.183A
0.496A
0.472A
0.197A
19.463
61.670%
662
11.0
0.732
12.143V
5.045V
3.380V
5.083V
31.560
230.21V
2
2.437A
0.990A
0.976A
0.394A
39.865
75.694%
664
11.0
0.834
12.138V
5.040V
3.376V
5.077V
52.666
230.21V
3
3.623A
1.488A
1.449A
0.592A
59.348
81.415%
665
11.0
0.879
12.134V
5.038V
3.374V
5.070V
72.896
230.21V
4
4.877A
1.985A
1.957A
0.790A
79.747
84.616%
666
11.0
0.907
12.129V
5.035V
3.372V
5.064V
94.246
230.21V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
17.6 mV
13.3 mV
14.9 mV
21.8 mV
Pass
20% Load
19.0 mV
12.7 mV
15.7 mV
22.2 mV
Pass
30% Load
21.9 mV
14.2 mV
17.0 mV
22.0 mV
Pass
40% Load
25.0 mV
15.4 mV
18.7 mV
17.1 mV
Pass
50% Load
28.4 mV
16.3 mV
22.1 mV
16.9 mV
Pass
60% Load
33.5 mV
18.0 mV
26.5 mV
18.0 mV
Pass
70% Load
38.1 mV
20.1 mV
28.9 mV
20.7 mV
Pass
80% Load
45.9 mV
22.6 mV
33.3 mV
23.2 mV
Pass
90% Load
54.5 mV
24.3 mV
37.3 mV
25.5 mV
Pass
100% Load
68.7 mV
35.7 mV
57.0 mV
30.5 mV
Fail
110% Load
84.6 mV
41.3 mV
61.2 mV
32.8 mV
Fail
Crossload 1
28.8 mV
18.7 mV
31.7 mV
20.4 mV
Pass
Crossload 2
69.6 mV
36.0 mV
53.3 mV
38.2 mV
Fail
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
17.6 mV
13.2 mV
15.6 mV
21.9 mV
Pass
20% Load
21.2 mV
17.5 mV
15.8 mV
26.5 mV
Pass
30% Load
21.6 mV
13.8 mV
16.7 mV
24.1 mV
Pass
40% Load
26.9 mV
16.3 mV
16.8 mV
23.6 mV
Pass
50% Load
28.7 mV
17.1 mV
18.1 mV
18.8 mV
Pass
60% Load
30.8 mV
20.1 mV
22.2 mV
18.8 mV
Pass
70% Load
35.8 mV
23.4 mV
29.7 mV
21.0 mV
Pass
80% Load
42.8 mV
23.5 mV
32.3 mV
22.4 mV
Pass
90% Load
48.3 mV
25.9 mV
32.8 mV
22.7 mV
Pass
100% Load
59.3 mV
33.3 mV
49.4 mV
24.3 mV
Pass
110% Load
68.7 mV
38.2 mV
55.0 mV
27.5 mV
Fail
Crossload 1
28.2 mV
22.0 mV
30.8 mV
24.3 mV
Pass
Crossload 2
62.5 mV
38.1 mV
50.2 mV
36.5 mV
Fail
The results above are not used in the certification process