Cables and Connectors(Non-accredited measurements)
Native Cables
Description
Cable Count
Connector Count (Total)
Gauge
ATX connector 20+4 pin (600mm)
1
1
16-20AWG
4+4 pin EPS12V (650mm)
1
1
18AWG
Modular Cables
6+2 pin PCIe (600mm+150mm)
2
4
18AWG
SATA (500mm+90mm+90mm+90mm)
2
8
18AWG
4 pin Molex (450mm+100mm+100mm+100mm)
2
8
18AWG
FDD (+100mm)
2
2
20AWG
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
25
25
70.8
3
0.8
Watts
130
849.6
15
9.6
Total Max. Power (W)
850
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
88.736%
Average Noise Output (>1450 Load Combinations)
27.95dBA
Average PF (>1450 Load Combinations)
0.987
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.0389W
Non-Accredited
12V Ripple (Full Load)
51.12mV
5V Ripple (Full Load)
13.69mV
3.3V Ripple (Full Load)
18.81mV
5VSB Ripple (Full Load)
21.94mV
12V Load Regulation
1.22%
5V Load Regulation
1.03%
3.3V Load Regulation
2.10%
5VSB Load Regulation
2.29%
Inrush Current
24.187A
Accredited
Average Efficiency (>1450 load combinations)
91.253%
Average Noise Output (>1450 Load Combinations)
29.01dBA
Average PF (>1450 Load Combinations)
0.951
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.0584W
Non-Accredited
12V Ripple (Full Load)
41.15mV
5V Ripple (Full Load)
14.49mV
3.3V Ripple (Full Load)
32.24mV
5VSB Ripple (Full Load)
21.01mV
12V Load Regulation
0.51%
5V Load Regulation
0.26%
3.3V Load Regulation
0.60%
5VSB Load Regulation
1.01%
Inrush Current
46.952A
Hold-Up Time & PWR_OK Signal
17.68ms
AC Loss to PWR_OK Hold Up Time
13.90ms
PWR_OK Inactive to DC Loss Delay
3.78ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
17.68
AC Loss to PWR_OK Hold Up Time (ms)
13.9
PWR_OK Inactive to DC Loss Delay (ms)
3.78
待機電源消耗
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.212
72.109%
0.030
5.064V
0.294
115.52V
2
0.087A
0.442
77.544%
0.056
5.064V
0.570
115.05V
3
0.532A
2.690
81.466%
0.244
5.057V
3.302
115.06V
4
3.001A
15.067
79.304%
0.444
5.020V
18.999
115.04V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.227
65.043%
0.009
5.044V
0.349
230.92V
2
0.090A
0.454
72.408%
0.016
5.044V
0.627
230.93V
3
0.550A
2.771
80.179%
0.086
5.037V
3.456
230.93V
4
1.000A
5.032
80.512%
0.146
5.031V
6.250
230.93V
5
1.500A
7.537
81.104%
0.199
5.024V
9.293
230.92V
6
2.500A
12.526
81.180%
0.275
5.010V
15.430
230.92V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.159A
1.985A
1.976A
0.990A
84.765
85.431%
1298
30.5
39.27°C
0.979
12.249V
5.033V
3.336V
5.041V
99.220
40.04°C
115.12V
2
11.345A
2.980A
2.970A
1.190A
169.643
89.813%
1394
31.2
39.77°C
0.976
12.233V
5.028V
3.330V
5.031V
188.884
40.74°C
115.11V
3
17.911A
3.488A
3.487A
1.391A
254.886
90.981%
1454
32.4
40.15°C
0.983
12.216V
5.021V
3.323V
5.022V
280.154
41.16°C
115.10V
4
24.468A
3.985A
3.978A
1.595A
339.731
91.141%
1524
33.8
40.67°C
0.988
12.202V
5.016V
3.316V
5.012V
372.754
41.89°C
115.10V
5
30.696A
4.984A
4.982A
1.798A
424.573
90.936%
1596
35.4
41.33°C
0.991
12.188V
5.012V
3.308V
5.000V
466.891
42.58°C
115.09V
6
36.953A
5.993A
5.996A
2.001A
509.606
90.408%
1704
37.3
41.98°C
0.992
12.173V
5.007V
3.300V
4.989V
563.674
43.43°C
115.09V
7
43.241A
7.002A
7.013A
2.203A
594.551
89.656%
1829
37.3
43.02°C
0.994
12.152V
5.002V
3.293V
4.979V
663.146
44.96°C
115.09V
8
49.532A
8.006A
8.034A
2.416A
679.523
88.774%
1847
39.9
43.67°C
0.995
12.136V
4.996V
3.286V
4.969V
765.450
46.04°C
115.09V
9
56.261A
8.516A
8.567A
2.417A
764.510
87.908%
1847
39.9
44.79°C
0.995
12.121V
4.989V
3.279V
4.962V
869.674
47.62°C
115.08V
10
62.765A
9.036A
9.075A
3.031A
849.400
87.092%
1847
39.9
45.60°C
0.996
12.104V
4.983V
3.271V
4.943V
975.295
48.64°C
115.08V
11
69.864A
9.053A
9.096A
3.037A
934.380
86.220%
1847
39.9
46.33°C
0.996
12.090V
4.975V
3.265V
4.935V
1083.710
49.95°C
115.08V
CL1
0.099A
16.025A
16.004A
0.004A
135.115
83.083%
1659
35.9
43.65°C
0.975
12.239V
5.047V
3.312V
5.032V
162.627
45.58°C
115.10V
CL2
54.126A
1.003A
1.003A
1.003A
670.582
89.484%
1847
39.9
44.41°C
0.994
12.143V
4.990V
3.300V
5.000V
749.385
46.69°C
115.11V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.181A
1.992A
1.989A
0.994A
84.862
85.989%
1265
30.0
38.32°C
0.806
12.211V
5.022V
3.314V
5.031V
98.689
41.23°C
230.90V
2
11.350A
2.989A
2.989A
1.194A
169.364
90.893%
1330
30.7
38.77°C
0.916
12.199V
5.020V
3.312V
5.026V
186.333
41.87°C
230.83V
3
17.920A
3.489A
3.475A
1.394A
254.454
92.348%
1445
32.1
39.35°C
0.950
12.190V
5.019V
3.309V
5.021V
275.539
42.75°C
230.77V
4
24.498A
3.988A
3.992A
1.595A
339.671
92.792%
1512
33.7
40.18°C
0.965
12.183V
5.017V
3.307V
5.017V
366.058
43.88°C
230.71V
5
30.753A
4.986A
4.992A
1.796A
424.990
92.775%
1596
35.4
41.05°C
0.970
12.177V
5.016V
3.305V
5.012V
458.086
45.13°C
230.67V
6
36.947A
5.985A
5.995A
1.998A
509.495
92.598%
1728
37.4
41.69°C
0.975
12.171V
5.014V
3.303V
5.007V
550.224
46.52°C
230.59V
7
43.214A
6.982A
6.998A
2.200A
594.804
92.277%
1838
39.8
42.82°C
0.978
12.165V
5.013V
3.301V
5.002V
644.588
47.97°C
230.63V
8
49.488A
7.986A
8.003A
2.402A
680.155
91.843%
1847
39.9
44.01°C
0.982
12.159V
5.012V
3.299V
4.997V
740.559
49.92°C
230.56V
9
56.168A
8.486A
8.494A
2.403A
765.068
91.439%
1847
39.9
45.19°C
0.984
12.152V
5.010V
3.296V
4.995V
836.697
51.69°C
230.50V
10
62.769A
8.987A
9.014A
2.505A
849.800
90.908%
1847
39.9
46.11°C
0.987
12.149V
5.009V
3.295V
4.991V
934.791
53.24°C
230.42V
11
69.775A
8.988A
9.020A
2.506A
934.562
90.426%
1847
39.9
47.40°C
0.988
12.144V
5.008V
3.293V
4.988V
1033.515
56.16°C
230.46V
CL1
0.140A
16.005A
15.999A
0.000A
135.075
84.051%
1679
36.2
43.58°C
0.903
12.207V
5.022V
3.312V
5.039V
160.706
47.71°C
230.93V
CL2
70.848A
1.002A
1.002A
1.000A
873.927
91.349%
1847
39.9
45.45°C
0.987
12.147V
5.010V
3.296V
5.014V
956.694
53.01°C
230.43V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.191A
0.491A
0.477A
0.194A
19.644
63.958%
1195
28.5
0.891
12.255V
5.036V
3.343V
5.059V
30.714
115.11V
2
2.411A
0.990A
0.985A
0.397A
39.822
77.206%
1205
28.7
0.962
12.252V
5.035V
3.341V
5.055V
51.579
115.10V
3
3.623A
1.480A
1.495A
0.590A
59.815
82.121%
1242
29.6
0.977
12.253V
5.034V
3.339V
5.050V
72.838
115.10V
4
4.833A
1.985A
1.974A
0.792A
79.775
85.158%
1255
29.8
0.981
12.249V
5.033V
3.338V
5.045V
93.679
115.10V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.184A
0.498A
0.481A
0.198A
19.558
65.074%
1160
27.1
0.433
12.215V
5.023V
3.316V
5.044V
30.055
230.92V
2
2.432A
0.996A
0.993A
0.397A
39.985
76.418%
1210
28.2
0.605
12.208V
5.023V
3.315V
5.041V
52.324
230.91V
3
3.610A
1.494A
1.477A
0.596A
59.462
82.490%
1225
28.8
0.712
12.205V
5.022V
3.315V
5.037V
72.084
230.90V
4
4.851A
1.991A
1.992A
0.795A
79.838
85.621%
1242
29.6
0.790
12.211V
5.022V
3.314V
5.034V
93.246
230.89V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
22.3 mV
5.1 mV
7.7 mV
4.5 mV
Pass
20% Load
20.5 mV
6.3 mV
9.1 mV
5.7 mV
Pass
30% Load
21.7 mV
6.6 mV
10.6 mV
7.2 mV
Pass
40% Load
23.7 mV
6.8 mV
11.5 mV
8.4 mV
Pass
50% Load
27.0 mV
8.3 mV
11.9 mV
13.8 mV
Pass
60% Load
29.7 mV
9.2 mV
12.6 mV
12.6 mV
Pass
70% Load
34.5 mV
9.5 mV
12.8 mV
14.9 mV
Pass
80% Load
39.1 mV
10.9 mV
13.6 mV
16.0 mV
Pass
90% Load
44.2 mV
11.9 mV
14.9 mV
17.9 mV
Pass
100% Load
51.1 mV
13.7 mV
18.8 mV
21.9 mV
Pass
110% Load
58.8 mV
15.2 mV
21.6 mV
24.6 mV
Pass
Crossload 1
23.2 mV
8.1 mV
9.5 mV
7.4 mV
Pass
Crossload 2
40.3 mV
9.8 mV
16.2 mV
16.8 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
18.7 mV
4.4 mV
6.9 mV
3.6 mV
Pass
20% Load
17.6 mV
5.6 mV
9.2 mV
5.0 mV
Pass
30% Load
19.0 mV
7.9 mV
17.2 mV
6.5 mV
Pass
40% Load
19.1 mV
6.5 mV
12.0 mV
7.9 mV
Pass
50% Load
23.3 mV
7.9 mV
15.2 mV
12.3 mV
Pass
60% Load
26.3 mV
9.7 mV
19.2 mV
12.3 mV
Pass
70% Load
30.5 mV
12.1 mV
26.2 mV
14.2 mV
Pass
80% Load
33.0 mV
14.8 mV
28.9 mV
16.3 mV
Pass
90% Load
37.4 mV
13.0 mV
30.1 mV
18.5 mV
Pass
100% Load
41.2 mV
14.5 mV
32.2 mV
21.0 mV
Pass
110% Load
47.7 mV
15.4 mV
34.0 mV
23.4 mV
Pass
Crossload 1
18.2 mV
9.5 mV
13.3 mV
8.4 mV
Pass
Crossload 2
42.2 mV
10.0 mV
21.0 mV
20.9 mV
Pass
The results above are not used in the certification process