Customer: Gamemax
GameMax HK Co., Limited Room 1006,
10/F Po Yip Building, 23 Hing Yip Street, Kwun Tong, Kowloon, Hong Kong

Lion Core 1000P

Report Number: 25PS3093A
Customer ID: 99
Lab ID: GM10003093

Test Report Results

Section A: Testing Equipment

Electronic Loads Chroma 63601-5 x2
Chroma 63600-2
Chroma 63640-80-80 x10
Chroma 63610-80-20
AC Sources Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500
Power Analyzers Rohde & Schwarz HMC8015, Rohde & Schwarz NPA701
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
EMI Analyzer TekBox TBMR-110M-EU
Isolation Transformer 4kVA
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)90.878%92.478%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.9910.957
Standby Power Consumption0.0681W0.1497W
ErP Lot 3/6 Ready
(EU) No 617/2013 Compliance
Average Efficiency VSB81.093%80.242%
Conducted Emissions EN55032 & CISPR 32Passed

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)14.61dBA14.18dBA
Noise Graphs

Section D: ATX

Efficiency With 10W (≤500W) or 2% (>500W) Load69.550
Hold Up Time25.70
Power OK20.30
Power OK to DC Loss5.40
Test\Rail+12V5V3.3V5VSB
100ms11.8964.9973.3435.069
10ms11.6584.9713.3195.018
1ms11.4334.9593.3074.995
0.1ms11.3704.9363.2874.964

Section E: Information about DUT

Model NameGamemax
Lab IDGM10003093
Serial Number-
Date of receiptNov 27, 2025
Testing DateJan 5, 2026
Report Issued DateJan 13, 2026
DUT Notes3093
Engineer NameIoannis Kalyviotis
Authorized By the Laboratory General ManagerAristeidis Bitziopoulos
Signature

Cables And Connectors

Modular Cables
Description Cable Count Connector Count (Total) Gauge Cable Type
ATX connector 20+4 pin (640mm) 1 1 16-20AWG Tinned Copper
4+4 pin EPS12V (700mm) 2 2 16AWG Tinned Copper
6+2 pin PCIe (650mm) 4 4 16AWG Tinned Copper
12+4 pin PCIe (650mm) (600W) 1 1 16-24AWG Tinned Copper
SATA (500mm+150mm+150mm+150mm) 1 4 18AWG Tinned Copper
4-pin Molex (450mm+150mm+150mm) / FDD (+155mm+150mm) 2 6 / 2 18-20AWG Tinned Copper

Technical Specifications

ManufacturerSohoo
ModelLion Core 1000P
Max DC Output1000W
Efficiency (115V)90.878%
Efficiency (230V)92.478%
Noise (115V)14.61 dB[A]
Noise (230V)14.18 dB[A]
ModularFully Modular
Operating Temperature (Continuous Full Load)0 - 50℃
Over Power Protection
Over Current (+12V) Protection
Over Temperature Protection
Short Circuit Protection
Surge Protection
Inrush Current Protection
Fan Failure Protection
No Load Operation
Cooling135mm Fluid Dynamic Bearing Fan (HA13525L12F-Z)
Semi-Passive Operation
Dimensions (W x H x D)150 x 85 x 160mm
Weight1.86 kg (4.10 lb)
Form FactorATX12V
ATX 3.1 & PCIe 5.1 ready
Alternative Low Power Mode (ALPM) compatible
WarrantyNo Info

DUT Specifications

Rated Voltage (Vrms)100-240
Rated Current (Arms)8-15
Rated Frequency (Hz)50-60
Rated Power (W)1000
TypeATX12V
Dimensions (W x H x D)150 x 85 x 160mm
Cooling135mm Fluid Dynamic Bearing Fan (HA13525L12F-Z)
Semi-Passive Operation
Cable DesignFully Modular

Section F: Deviation Additions, deviations, and exceptions to the method table

Efficiency Uncertainty Estimation

The Efficiency Measurement’s Uncertainty is ±0.15%

The reported expanded uncertainty (U) was derived as the product of the combined standard uncertainty (u) and the coverage factor k = 2, corresponding to a confidence interval of approximately 95%. Measurement uncertainty was determined in accordance with JCGM Guide 100:2008, "Guide to the Expression of Uncertainty in Measurements". The estimate of the reported uncertainty pertains to values obtained during the measurements and does not account for possible long-term changes.

Efficiency Measurement Uncertainty Budget

Source of Uncertainty Standard Uncertainty, u(xi) Relative Standard Uncertainty, u(xi)/xi
Intralab Reproducibility 0.0310 0.00031
Electronic loads Calibration 0.0500 0.00050
Power Analyzer Calibration 0.0250 0.00025
Operator and Test Fixture 0.0350 0.00035
Relative Combined Standard Uncertainty (RSS): 0.00073
% Expanded Uncertainty U (k=2, norm): 0.15
Noise Output  Uncertainty Estimation

The Noise Measurement’s Uncertainty is ±1.23 dBA

The reported expanded uncertainty (U) was derived as the product of the combined standard uncertainty (u) and the coverage factor k = 2, corresponding to a confidence interval of approximately 95%. Measurement uncertainty was determined in accordance with JCGM Guide 100:2008, "Guide to the Expression of Uncertainty in Measurements". The estimate of the reported uncertainty pertains to values obtained during the measurements and does not account for possible long-term changes.

Noise Output Measurement Uncertainty Budget
Source of Uncertainty

Standard Uncertainty, u(xi)/xi

(dBA)
Intralab Reproducibility 0.031
Mic Calibrator 4231 calibration 0.200
Microphone frequency response 0.577
Temperature 0.12
 Position error  0.058
Relative Combined Standard Uncertainty (RSS): 0.61
Expanded Uncertainty U (k=2, norm): 1.23
Conducted Electromagnetic Interference (EMI) Emissions Uncertainty Estimation

The Conducted EMI Emissions Measurement’s Uncertainty is ±1.75 dB

The reported expanded uncertainty (U) was derived as the product of the combined standard uncertainty (u) and the coverage factor k = 2, corresponding to a confidence interval of approximately 95%. Measurement uncertainty was determined in accordance with JCGM Guide 100:2008, "Guide to the Expression of Uncertainty in Measurements". The estimate of the reported uncertainty pertains to values obtained during the measurements and does not account for possible long-term changes.

Conducted EMI Measurement Uncertainty Budget
Source of Uncertainty

Standard Uncertainty, u(xi)/xi

(dB)
Spectrum Analyzer total measurement uncertainty 0.250
Spectrum Analyzer calibration 0.500
Noise and Signal Quality 0.577
Bandwidth and Resolution Bandwidth (RBW) 0.289
Measurement time and Averaging  0.115
Environmental Factors 0.115
Relative Combined Standard Uncertainty (RSS): 0.87
Expanded Uncertainty U (k=2, norm): 1.75