SECTION B: Fan Testing Instrument Technical Specifications
Manufacturer
Long Win Science & Technology Corporation
Model Number
LW-9266
Air Flow Rate
2.4 – 250 CFM
Accuracy of Air Flow Rate
< 3.5% INFS
Repeatability error
< 2%
Static pressure
0-20mmAq (100mmAq with the high static pressure throttle device)
Overall Dimensions
0.7 (W) x 2.2 (L) x 1.6 (H) m
Power Source
220VAC, 5A, Single Phase, 50/60Hz
Based on Standards
ISO 5801-2007, AMCA 210-0, ASHRAE 51-2007, IEC 61591-2005, GB/T 1236-200
SECTION C: PHI Performance Levels
Pressure at 25 dB(A)
P (mmAq)
1.15
Airflow at 25 dB(A)
Q (CFM)
59.84
SECTION D: Information about DUT
Product Identification Details
Brand
1
Model
HA13525H12F-Z (0.5A)
Serial Number
-
Product Specifications
Manufacturer-Provided Information
Bearing
Fluid Dynamic
Connector
2-Pin
Cable length (mm)
145
Daisy-chain
None
RGB Connector
None
RGB Daisy-chain
None
Cybenetics Measurements
Max Speed (RPM)
2315
Max Airflow (CFM)
120.34
Max Static Pressure (mmAq)
3.58
Max Fan Noise Level (dBA)
41.60
Fan Max Current (A)
0.38
Fan Weight (gr)
161
Dimensions (W x H x D)
135mm x 135mm x 25mm
Cybenetics Testing Information
Lab ID
13500111
Date of receipt
-
Testing Date
-
Report Issued Date
Apr 26, 2024
Engineer Name
Georgios Theodoros Sarimpalas
SECTION E: Long Win LW-9266 - Pressure and Airflow
Voltage
Max Airflow (CFM)
Max Static Pressure (mmAq)
Fan Speed (RPM)
Max Power (W)
3.14V
37.44
0.47
766 - 821
0.26
3.5V
42.97
0.57
843 - 899
0.33
4V
47.24
0.71
946 - 1017
0.44
4.5V
53.36
0.86
1044 - 1126
0.57
5V
58.83
1.03
1137 - 1230
0.72
6V
69.80
1.38
1312 - 1438
1.05
7V
79.02
1.77
1472 - 1641
1.46
8V
90.26
2.14
1619 - 1815
1.92
9V
97.44
2.51
1752 - 1966
2.46
10V
105.82
2.87
1873 - 2118
3.08
11V
114.04
3.24
1987 - 2238
3.76
12V
120.34
3.58
2090 - 2382
4.52
Airflow (CFM)
Static Pressure (mmAq)
Fan Speed (RPM)
Current (A)
Power (W)
0.00
0.47
766
0.084
0.26
5.28
0.40
776
0.081
0.25
10.70
0.33
785
0.079
0.25
15.85
0.26
802
0.075
0.24
21.31
0.24
798
0.076
0.24
26.65
0.13
804
0.075
0.24
32.05
0.06
806
0.074
0.23
37.44
-0.01
821
0.071
0.22
Airflow (CFM)
Static Pressure (mmAq)
Fan Speed (RPM)
Current (A)
Power (W)
0.00
0.57
843
0.095
0.33
6.05
0.47
856
0.092
0.32
12.22
0.39
868
0.089
0.31
18.12
0.31
885
0.085
0.30
24.30
0.27
883
0.086
0.30
30.51
0.16
889
0.085
0.30
36.77
0.06
898
0.083
0.29
42.97
-0.01
899
0.082
0.29
Airflow (CFM)
Static Pressure (mmAq)
Fan Speed (RPM)
Current (A)
Power (W)
0.00
0.71
946
0.111
0.44
6.69
0.58
960
0.107
0.43
13.50
0.49
975
0.104
0.42
20.00
0.42
993
0.100
0.40
26.79
0.36
990
0.101
0.40
33.72
0.20
1003
0.098
0.39
40.51
0.08
1005
0.097
0.39
47.24
0.00
1017
0.094
0.38
Airflow (CFM)
Static Pressure (mmAq)
Fan Speed (RPM)
Current (A)
Power (W)
0.00
0.86
1044
0.127
0.57
7.52
0.71
1061
0.123
0.55
14.91
0.61
1076
0.120
0.54
22.61
0.48
1101
0.114
0.51
30.41
0.43
1095
0.115
0.52
38.14
0.23
1111
0.111
0.50
45.47
0.10
1119
0.110
0.50
53.36
0.01
1126
0.109
0.49
Airflow (CFM)
Static Pressure (mmAq)
Fan Speed (RPM)
Current (A)
Power (W)
0.00
1.03
1137
0.143
0.72
8.25
0.85
1157
0.138
0.69
16.30
0.72
1172
0.135
0.68
24.82
0.58
1204
0.128
0.64
33.52
0.49
1196
0.130
0.65
41.99
0.29
1213
0.126
0.63
50.13
0.14
1223
0.124
0.62
58.83
0.00
1230
0.122
0.61
Airflow (CFM)
Static Pressure (mmAq)
Fan Speed (RPM)
Current (A)
Power (W)
0.00
1.38
1312
0.175
1.05
9.86
1.13
1339
0.169
1.01
19.25
0.95
1360
0.164
0.98
29.56
0.79
1396
0.156
0.94
39.93
0.64
1384
0.159
0.95
49.22
0.41
1410
0.153
0.92
59.48
0.18
1426
0.150
0.90
69.80
0.00
1438
0.148
0.89
Airflow (CFM)
Static Pressure (mmAq)
Fan Speed (RPM)
Current (A)
Power (W)
0.00
1.77
1472
0.208
1.46
11.28
1.46
1501
0.201
1.41
21.96
1.24
1530
0.195
1.37
33.75
1.00
1574
0.185
1.30
43.96
0.84
1574
0.185
1.30
55.90
0.55
1598
0.179
1.25
67.63
0.24
1621
0.174
1.22
79.02
0.03
1641
0.171
1.20
Airflow (CFM)
Static Pressure (mmAq)
Fan Speed (RPM)
Current (A)
Power (W)
0.00
2.14
1619
0.240
1.92
12.90
1.77
1651
0.232
1.86
25.04
1.49
1693
0.224
1.79
38.60
1.24
1737
0.214
1.71
50.37
1.01
1728
0.215
1.72
63.70
0.57
1767
0.207
1.66
77.15
0.24
1785
0.203
1.62
90.26
0.00
1815
0.196
1.57
Airflow (CFM)
Static Pressure (mmAq)
Fan Speed (RPM)
Current (A)
Power (W)
0.00
2.51
1752
0.273
2.46
14.00
2.08
1792
0.264
2.38
27.15
1.77
1834
0.255
2.30
41.91
1.48
1884
0.244
2.20
54.55
1.24
1874
0.246
2.21
69.07
0.66
1921
0.235
2.12
83.83
0.29
1942
0.231
2.08
97.44
0.01
1966
0.224
2.02
Airflow (CFM)
Static Pressure (mmAq)
Fan Speed (RPM)
Current (A)
Power (W)
0.00
2.87
1873
0.308
3.08
13.75
2.42
1917
0.297
2.97
29.56
2.02
1967
0.286
2.86
43.02
1.71
2023
0.274
2.74
58.93
1.40
2016
0.275
2.75
74.99
0.72
2069
0.263
2.63
89.13
0.42
2097
0.257
2.57
105.82
-0.02
2118
0.250
2.50
Airflow (CFM)
Static Pressure (mmAq)
Fan Speed (RPM)
Current (A)
Power (W)
0.00
3.24
1987
0.342
3.76
14.87
2.73
2036
0.330
3.63
32.16
2.25
2093
0.318
3.50
46.66
1.95
2145
0.305
3.36
64.30
1.51
2142
0.306
3.37
81.44
0.80
2196
0.294
3.23
96.48
0.36
2226
0.288
3.17
114.04
-0.04
2238
0.286
3.15
Airflow (CFM)
Static Pressure (mmAq)
Fan Speed (RPM)
Current (A)
Power (W)
0.00
3.58
2090
0.377
4.52
15.71
3.03
2141
0.364
4.37
34.00
2.55
2201
0.351
4.21
49.51
2.18
2264
0.336
4.03
67.95
1.71
2266
0.336
4.03
83.27
1.06
2328
0.323
3.88
101.93
0.50
2351
0.317
3.80
120.34
-0.05
2382
0.308
3.70
SECTION F: General Performance
Fan Percentage RPM LongWin
Fan Percentage CFM
Fan Percentage Pressure
Fan Percentage Power
Fan Percentage Amps
Fan Percentage Noise
Fan Speed Noise
Fan Noise Speed
SECTION G: Uncertainty
Fan Performance Uncertainty Estimation
General Statement
Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.
The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.
The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.
Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.
Expanded Measurement Uncertainty by Measurement Type
Measurement
Expanded Uncertainty U (k=2, norm)
Fan Air Flow
±1.23176 % of reading (k=2) — e.g. ±3.69 CFM at 25 CFM, ±4.29 at 92 CFM, ±7.15 at 250 CFM
Fan Static Pressure
±0.6727 Pa
Air flow uncertainty is relative to the reading: U(Q) = 2·√[(1.8200)² + (0.0123176·Q)²] CFM, valid over the declared measuring range 2.4 – 250 CFM.
The reported static pressure uncertainty applies over the 0 – 20 mmAq (0 – 196.1 Pa) measuring range of the Long Win LW-9266 apparatus. The apparatus can be extended to 100 mmAq (981 Pa) with the high static pressure throttle device; the uncertainty of that extended range has not been separately verified and the value stated above does not apply to it.
1 HA13525H12F-Z (0.5A)
Front
Rear
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern