This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
The results above are not used in the certification process
Light Load Tests 115V
Efficiency at Low Loads Nidus 500 PG-5001-BR -115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.217A
0.502A
0.483A
0.202A
19.709
58.103%
0000
<6.0
0.896
12.003V
4.988V
3.294V
4.982V
33.921
115.12V
2
2.460A
1.001A
1.000A
0.400A
39.791
73.101%
0000
<6.0
0.953
11.999V
4.984V
3.294V
4.974V
54.433
115.12V
3
3.702A
1.497A
1.514A
4.967A
59.840
84.034%
0000
<6.0
0.967
11.996V
4.980V
3.293V
4.967V
71.209
115.12V
4
4.940A
2.009A
2.003A
0.805A
79.835
86.211%
0000
<6.0
0.978
11.994V
4.977V
3.291V
4.960V
92.604
115.11V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
5.6 mV
5.6 mV
4.0 mV
3.1 mV
Pass
20% Load
8.3 mV
8.2 mV
4.6 mV
7.6 mV
Pass
30% Load
9.3 mV
5.0 mV
4.2 mV
3.8 mV
Pass
40% Load
9.7 mV
4.6 mV
4.3 mV
4.2 mV
Pass
50% Load
10.0 mV
4.9 mV
4.2 mV
4.8 mV
Pass
60% Load
9.4 mV
12.4 mV
5.8 mV
12.1 mV
Pass
70% Load
9.7 mV
8.8 mV
4.7 mV
8.0 mV
Pass
80% Load
9.8 mV
6.2 mV
4.6 mV
5.3 mV
Pass
90% Load
10.9 mV
6.9 mV
5.1 mV
6.7 mV
Pass
100% Load
12.7 mV
7.1 mV
5.8 mV
7.1 mV
Pass
110% Load
13.3 mV
7.2 mV
6.2 mV
7.4 mV
Pass
Crossload 1
19.5 mV
10.9 mV
7.4 mV
6.2 mV
Pass
Crossload 2
12.5 mV
5.3 mV
5.1 mV
7.6 mV
Pass
The results above are not used in the certification process
Corsair AX1500i
Top side
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern