ErP Lot 6 2010: ✓
ErP Lot 6 2013: Partially
ErP Lot 3 2014 & CEC: ✗
符合(EU) No 617/2013规范
✓
Performance Summary
Accredited
平均效率 (>1450 load combinations)
89.935%
Average Noise Output (>1450 Load Combinations)
27.53dBA
PF平均值 (>1450 Load Combinations)
0.980
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
待机功耗
0.1224W
Non-Accredited
12V Ripple (Full Load)
41.90mV
5V Ripple (Full Load)
18.94mV
3.3V Ripple (Full Load)
28.21mV
5VSB Ripple (Full Load)
15.73mV
12V Load Regulation
0.90%
5V Load Regulation
2.24%
3.3V Load Regulation
2.40%
5VSB Load Regulation
2.32%
Inrush Current
33.613A
Accredited
平均效率 (>1450 load combinations)
92.226%
Average Noise Output (>1450 Load Combinations)
27.12dBA
PF平均值 (>1450 Load Combinations)
0.931
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
待机功耗
0.2680W
Non-Accredited
12V Ripple (Full Load)
45.08mV
5V Ripple (Full Load)
17.98mV
3.3V Ripple (Full Load)
29.54mV
5VSB Ripple (Full Load)
15.73mV
12V Load Regulation
0.57%
5V Load Regulation
1.70%
3.3V Load Regulation
1.75%
5VSB Load Regulation
1.85%
Inrush Current
58.157A
保持时间 & PWR_OK 信号
11.20ms
AC Loss to PWR_OK Hold Up Time
9.90ms
PWR_OK Inactive to DC Loss Delay
1.30ms
OPP (0.00°C / 0.00°C)
-
-
保持时间 & PWR_OK 信号
Hold-Up Time (ms)
11.2
AC Loss to PWR_OK Hold Up Time (ms)
9.9
PWR_OK Inactive to DC Loss Delay (ms)
1.3
待机功耗
Tables
Graphs
转换效率图表
信息
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
信息
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
噪声图
信息
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
信息
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
传导发射 EN 55032 & CISPR 32
Indicative Performance
高环温电源转换效率
信息
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB效率
信息
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.