Protechnic Electric MGA8012YS-A15 (80mm, 12V, 0.28A, Sleeve Bearing)
5VSB Circuit
Rectifier
1x A-Power AP03N70I-H FET (700V, 2.5A, 4.4 Ohm)
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary 115V
Accredited
Average Efficiency (>1450 load combinations)
87.847%
Average Noise Output (>1450 Load Combinations)
29.14dBA
Average PF (>1450 Load Combinations)
0.992
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1207W
Non-Accredited
12V Ripple (Full Load)
61.55mV
5V Ripple (Full Load)
39.36mV
3.3V Ripple (Full Load)
26.07mV
5VSB Ripple (Full Load)
14.06mV
12V Load Regulation
1.62%
5V Load Regulation
2.34%
3.3V Load Regulation
2.49%
5VSB Load Regulation
3.64%
Inrush Current
39.893A
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
21.7
AC Loss to PWR_OK Hold Up Time (ms)
17.5
PWR_OK Inactive to DC Loss Delay (ms)
4.2
待機電源消耗
Tables 115V
Graphs 115V
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.228
59.843%
0.035
5.063V
0.381
115.39V
2
0.090A
0.456
69.939%
0.059
5.063V
0.652
115.39V
3
0.550A
2.775
78.191%
0.256
5.044V
3.549
115.38V
4
1.000A
5.024
79.975%
0.351
5.024V
6.282
115.38V
5
1.500A
7.501
79.283%
0.409
5.000V
9.461
115.37V
6
2.499A
12.380
76.971%
0.463
4.953V
16.084
115.36V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.737A
1.966A
1.958A
0.998A
54.473
82.258%
1412
15.8
38.29°C
0.962
12.011V
5.087V
3.369V
5.011V
66.222
46.83°C
115.31V
2
6.547A
2.957A
2.947A
1.202A
109.366
87.493%
1412
15.8
38.60°C
0.980
11.984V
5.074V
3.359V
4.995V
125.000
48.55°C
115.23V
3
10.761A
3.456A
3.430A
1.406A
164.872
89.239%
1412
15.8
39.15°C
0.989
11.976V
5.064V
3.352V
4.979V
184.753
49.84°C
115.14V
4
14.908A
3.960A
3.946A
1.612A
219.690
89.562%
1594
20.0
39.39°C
0.995
11.972V
5.053V
3.345V
4.964V
245.293
51.52°C
115.16V
5
18.738A
4.962A
4.946A
1.820A
274.582
89.470%
1919
25.2
40.07°C
0.997
11.958V
5.040V
3.336V
4.948V
306.899
53.20°C
115.07V
6
22.577A
5.970A
5.952A
2.029A
329.510
89.145%
2265
30.2
40.84°C
0.998
11.946V
5.026V
3.326V
4.931V
369.632
55.27°C
114.99V
7
26.472A
6.983A
6.964A
2.240A
384.809
88.587%
2602
34.2
42.13°C
0.998
11.926V
5.012V
3.317V
4.913V
434.385
58.24°C
115.01V
8
30.402A
8.005A
7.983A
2.453A
440.109
87.845%
2957
38.4
42.55°C
0.999
11.897V
4.998V
3.307V
4.895V
501.004
61.20°C
114.92V
9
34.754A
8.522A
8.489A
2.457A
494.630
87.030%
3250
40.7
44.29°C
0.999
11.858V
4.988V
3.299V
4.886V
568.343
63.97°C
114.83V
10
39.131A
9.043A
9.027A
2.567A
549.744
85.951%
3460
42.2
45.73°C
0.999
11.820V
4.977V
3.291V
4.870V
639.602
66.99°C
114.84V
11
44.160A
9.055A
9.046A
2.572A
604.956
84.953%
3460
42.2
46.73°C
0.999
11.724V
4.971V
3.284V
4.862V
712.108
69.73°C
114.75V
CL1
0.737A
14.003A
13.999A
0.000A
125.036
82.678%
2745
35.6
44.38°C
0.985
11.993V
4.981V
3.318V
5.026V
151.233
58.28°C
115.19V
CL2
45.005A
1.002A
1.000A
1.000A
545.702
86.687%
3450
42.0
45.35°C
0.999
11.829V
5.046V
3.322V
4.960V
629.508
63.22°C
114.77V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.204A
0.490A
0.473A
0.198A
19.564
68.547%
1412
15.8
0.826
12.015V
5.101V
3.379V
5.054V
28.541
115.36V
2
2.465A
0.984A
0.978A
0.397A
39.934
79.834%
1412
15.8
0.939
12.015V
5.096V
3.375V
5.043V
50.021
115.33V
3
3.669A
1.473A
1.451A
0.597A
59.458
83.994%
1412
15.8
0.965
12.010V
5.090V
3.371V
5.031V
70.788
115.30V
4
4.937A
1.967A
1.961A
0.797A
79.862
86.137%
1412
15.8
0.972
12.003V
5.085V
3.366V
5.019V
92.715
115.27V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
10.9 mV
15.9 mV
13.7 mV
11.5 mV
Pass
20% Load
28.6 mV
23.1 mV
15.5 mV
14.5 mV
Pass
30% Load
28.0 mV
22.7 mV
14.9 mV
7.8 mV
Pass
40% Load
29.2 mV
22.9 mV
15.6 mV
8.7 mV
Pass
50% Load
33.2 mV
25.5 mV
16.5 mV
9.3 mV
Pass
60% Load
33.9 mV
28.8 mV
18.9 mV
10.2 mV
Pass
70% Load
36.6 mV
32.1 mV
20.7 mV
10.6 mV
Pass
80% Load
38.0 mV
33.2 mV
20.9 mV
11.0 mV
Pass
90% Load
46.3 mV
36.5 mV
22.9 mV
12.3 mV
Pass
100% Load
61.6 mV
39.4 mV
26.1 mV
14.1 mV
Pass
110% Load
97.3 mV
41.8 mV
27.3 mV
15.2 mV
Pass
Crossload 1
33.4 mV
26.5 mV
18.7 mV
17.0 mV
Pass
Crossload 2
60.2 mV
38.3 mV
25.4 mV
18.2 mV
Pass
The results above are not used in the certification process