Globe Fan S1201512MB (12V, 0.25A, 120mm, Fluid Dynamic Bearing)
5VSB Circuit
Rectifiers
2x Infineon 060N03L 1x P10V45SP SBR (45V, 10A)
Standby PWM Controller
SANKEN STR-A6069H
-12V Circuit
Rectifier
KEC KIA7912PI (-12V, 1A)
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
ErP Lot 3/6 2010: ✓
ErP Lot 3/6 2013: ✓
ErP Lot 3/6 2014, CEC: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
88.839%
Average Noise Output (>1450 Load Combinations)
25.49dBA
Average PF (>1450 Load Combinations)
0.996
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.0744W
Non-Accredited
12V Ripple (Full Load)
45.87mV
5V Ripple (Full Load)
23.57mV
3.3V Ripple (Full Load)
31.86mV
5VSB Ripple (Full Load)
21.32mV
12V Load Regulation
0.72%
5V Load Regulation
1.78%
3.3V Load Regulation
2.25%
5VSB Load Regulation
3.88%
Inrush Current
88.035A
Accredited
Average Efficiency (>1450 load combinations)
90.635%
Average Noise Output (>1450 Load Combinations)
25.66dBA
Average PF (>1450 Load Combinations)
0.971
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1140W
Non-Accredited
12V Ripple (Full Load)
48.92mV
5V Ripple (Full Load)
22.47mV
3.3V Ripple (Full Load)
29.87mV
5VSB Ripple (Full Load)
21.38mV
12V Load Regulation
0.75%
5V Load Regulation
1.74%
3.3V Load Regulation
2.19%
5VSB Load Regulation
3.80%
Inrush Current
69.895A
Hold-Up Time & PWR_OK Signal
16.90ms
AC Loss to PWR_OK Hold Up Time
15.70ms
PWR_OK Inactive to DC Loss Delay
1.20ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
16.9
AC Loss to PWR_OK Hold Up Time (ms)
15.7
PWR_OK Inactive to DC Loss Delay (ms)
1.2
待機電源消耗
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.041A
0.212
61.449%
0.049
5.118V
0.345
115.17V
2
0.087A
0.446
70.126%
0.087
5.116V
0.636
115.17V
3
0.542A
2.760
79.654%
0.271
5.094V
3.465
115.17V
4
1.002A
5.081
79.903%
0.322
5.072V
6.359
115.17V
5
1.501A
7.580
80.152%
0.347
5.049V
9.457
115.17V
6
3.002A
14.927
78.042%
0.387
4.973V
19.127
115.16V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.213
54.897%
0.017
5.118V
0.388
230.38V
2
0.087A
0.446
64.173%
0.030
5.116V
0.695
230.38V
3
0.542A
2.762
74.287%
0.140
5.093V
3.718
230.39V
4
1.002A
5.082
77.505%
0.207
5.072V
6.557
230.38V
5
1.502A
7.581
79.200%
0.252
5.048V
9.572
230.38V
6
3.001A
14.928
78.676%
0.319
4.974V
18.974
230.38V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.117A
1.974A
1.954A
0.996A
59.787
83.863%
1400
27.3
38.14°C
0.972
12.261V
5.056V
3.374V
5.016V
71.291
40.25°C
115.17V
2
7.260A
2.968A
2.938A
1.199A
119.813
88.488%
1435
28.6
38.70°C
0.992
12.252V
5.047V
3.366V
5.000V
135.401
40.95°C
115.16V
3
11.752A
3.478A
3.446A
1.400A
179.885
89.971%
1455
29.5
38.95°C
0.995
12.237V
5.038V
3.359V
4.985V
199.937
41.57°C
115.16V
4
16.250A
3.975A
3.935A
1.607A
239.761
90.528%
1550
30.2
39.17°C
0.997
12.221V
5.030V
3.352V
4.970V
264.847
42.18°C
115.16V
5
20.419A
4.980A
4.932A
1.816A
299.775
90.480%
1560
30.4
39.79°C
0.998
12.209V
5.019V
3.343V
4.955V
331.318
43.12°C
115.16V
6
24.585A
5.987A
5.931A
2.020A
359.735
90.148%
1610
31.3
40.24°C
0.998
12.202V
5.009V
3.335V
4.940V
399.048
44.15°C
115.16V
7
28.755A
7.009A
6.939A
2.231A
419.741
89.657%
1655
32.2
41.27°C
0.999
12.194V
4.999V
3.326V
4.924V
468.164
45.71°C
115.16V
8
32.928A
8.023A
7.956A
2.445A
479.674
89.069%
1765
34.2
42.46°C
0.999
12.186V
4.988V
3.318V
4.906V
538.541
47.53°C
115.16V
9
37.532A
8.534A
8.484A
2.445A
539.710
88.458%
1830
34.9
43.70°C
0.999
12.180V
4.980V
3.311V
4.900V
610.130
49.77°C
115.16V
10
41.890A
9.063A
8.995A
3.084A
599.662
87.718%
1860
35.4
44.83°C
0.999
12.173V
4.970V
3.302V
4.861V
683.621
51.84°C
115.17V
11
46.829A
9.071A
9.014A
3.090A
659.593
86.965%
1870
35.6
46.07°C
0.999
12.169V
4.964V
3.296V
4.852V
758.455
53.81°C
115.16V
CL1
0.098A
13.019A
13.003A
0.004A
110.018
81.865%
1790
34.5
44.20°C
0.993
12.239V
5.011V
3.350V
5.072V
134.390
50.75°C
115.17V
CL2
49.948A
1.005A
1.002A
1.002A
622.143
88.269%
1850
35.2
44.58°C
0.999
12.189V
5.002V
3.323V
4.960V
704.829
51.54°C
115.17V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.121A
1.974A
1.955A
0.996A
59.825
84.521%
1435
28.6
38.07°C
0.851
12.259V
5.055V
3.373V
5.012V
70.781
42.86°C
230.17V
2
7.262A
2.970A
2.939A
1.201A
119.846
89.970%
1423
28.2
38.17°C
0.945
12.251V
5.047V
3.365V
4.996V
133.207
43.26°C
230.18V
3
11.755A
3.476A
3.454A
1.405A
179.938
91.666%
1455
29.5
38.52°C
0.969
12.236V
5.038V
3.357V
4.980V
196.297
44.47°C
230.19V
4
16.255A
3.972A
3.940A
1.611A
239.810
92.199%
1560
30.4
38.86°C
0.981
12.220V
5.030V
3.349V
4.966V
260.100
45.79°C
230.19V
5
20.423A
4.976A
4.938A
1.815A
299.804
92.289%
1613
30.9
39.61°C
0.987
12.209V
5.020V
3.341V
4.949V
324.855
47.48°C
230.20V
6
24.592A
5.984A
5.938A
2.025A
359.790
92.091%
1650
31.4
40.50°C
0.992
12.200V
5.011V
3.333V
4.934V
390.691
49.28°C
230.21V
7
28.759A
7.002A
6.945A
2.236A
419.791
91.739%
1755
33.4
41.10°C
0.992
12.194V
5.002V
3.324V
4.917V
457.593
51.24°C
230.20V
8
32.936A
8.014A
7.960A
2.446A
479.687
91.295%
1765
34.2
42.78°C
0.995
12.185V
4.990V
3.315V
4.900V
525.426
53.80°C
230.23V
9
37.542A
8.528A
8.493A
2.451A
539.770
90.887%
1810
35.3
43.70°C
0.995
12.178V
4.983V
3.308V
4.893V
593.889
56.04°C
230.22V
10
41.895A
9.058A
9.004A
3.091A
599.685
90.318%
1860
35.4
45.04°C
0.996
12.172V
4.973V
3.298V
4.852V
663.972
59.32°C
230.23V
11
46.838A
9.064A
9.020A
3.095A
659.617
89.800%
1870
35.6
46.29°C
0.997
12.168V
4.965V
3.292V
4.845V
734.543
62.54°C
230.23V
CL1
0.101A
13.018A
13.003A
0.005A
110.263
83.271%
1830
34.9
44.87°C
0.939
12.234V
5.021V
3.356V
5.084V
132.414
56.16°C
230.23V
CL2
49.955A
1.001A
1.004A
1.002A
622.243
90.928%
1870
35.6
44.47°C
0.996
12.190V
4.998V
3.315V
4.951V
684.326
59.15°C
230.25V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.195A
0.492A
0.471A
0.196A
19.704
66.381%
1270
24.8
0.914
12.242V
5.065V
3.381V
5.057V
29.683
115.16V
2
2.411A
0.980A
0.973A
0.396A
39.750
78.721%
1270
24.8
0.956
12.238V
5.060V
3.378V
5.045V
50.495
115.16V
3
3.621A
1.477A
1.481A
0.596A
59.867
84.091%
1365
26.5
0.972
12.261V
5.058V
3.375V
5.035V
71.193
115.16V
4
4.829A
1.975A
1.955A
0.796A
79.754
86.268%
1365
26.5
0.983
12.255V
5.054V
3.373V
5.025V
92.449
115.16V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.196A
0.491A
0.472A
0.196A
19.716
67.164%
1365
26.5
0.608
12.244V
5.063V
3.380V
5.054V
29.355
230.14V
2
2.414A
0.978A
0.976A
0.396A
39.784
79.751%
1400
27.3
0.760
12.239V
5.059V
3.376V
5.042V
49.885
230.16V
3
3.625A
1.474A
1.481A
0.596A
59.892
84.772%
1343
26.2
0.850
12.260V
5.057V
3.374V
5.031V
70.651
230.16V
4
4.835A
1.971A
1.954A
0.796A
79.791
87.308%
1393
27.2
0.892
12.254V
5.053V
3.371V
5.020V
91.390
230.16V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
8.1 mV
8.0 mV
11.9 mV
6.0 mV
Pass
20% Load
10.7 mV
9.2 mV
14.0 mV
7.8 mV
Pass
30% Load
13.7 mV
11.0 mV
17.7 mV
8.8 mV
Pass
40% Load
17.3 mV
12.1 mV
18.6 mV
10.1 mV
Pass
50% Load
22.0 mV
14.6 mV
19.6 mV
11.7 mV
Pass
60% Load
27.6 mV
16.1 mV
21.7 mV
13.5 mV
Pass
70% Load
30.3 mV
17.8 mV
25.5 mV
15.3 mV
Pass
80% Load
36.1 mV
20.2 mV
27.6 mV
16.8 mV
Pass
90% Load
40.0 mV
21.4 mV
30.1 mV
19.2 mV
Pass
100% Load
45.9 mV
23.6 mV
31.9 mV
21.3 mV
Pass
110% Load
57.4 mV
25.2 mV
35.8 mV
23.8 mV
Pass
Crossload 1
14.1 mV
13.7 mV
18.7 mV
11.1 mV
Pass
Crossload 2
52.8 mV
21.9 mV
30.2 mV
18.8 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.1 mV
9.3 mV
7.7 mV
6.5 mV
Pass
20% Load
9.4 mV
9.6 mV
8.8 mV
8.2 mV
Pass
30% Load
12.5 mV
11.4 mV
9.4 mV
9.0 mV
Pass
40% Load
16.1 mV
11.5 mV
10.6 mV
10.3 mV
Pass
50% Load
21.6 mV
13.1 mV
12.5 mV
11.9 mV
Pass
60% Load
27.5 mV
15.2 mV
14.8 mV
13.6 mV
Pass
70% Load
41.0 mV
18.8 mV
45.6 mV
18.3 mV
Pass
80% Load
34.7 mV
18.8 mV
19.6 mV
17.6 mV
Pass
90% Load
40.1 mV
20.0 mV
20.9 mV
19.6 mV
Pass
100% Load
46.4 mV
21.5 mV
22.9 mV
21.6 mV
Pass
110% Load
93.7 mV
24.1 mV
23.6 mV
29.6 mV
Pass
Crossload 1
11.9 mV
14.4 mV
16.0 mV
10.6 mV
Pass
Crossload 2
54.1 mV
19.5 mV
18.3 mV
19.2 mV
Pass
The results above are not used in the certification process