ErP Lot 3/6 2010: ✓
ErP Lot 3/6 2013: Partially
ErP Lot 3/6 2014, CEC: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary 115V
Accredited
Average Efficiency (>1450 load combinations)
84.922%
Average Noise Output (>1450 Load Combinations)
28.95dBA
Average PF (>1450 Load Combinations)
0.984
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1312W
Non-Accredited
12V Ripple (Full Load)
11.82mV
5V Ripple (Full Load)
9.25mV
3.3V Ripple (Full Load)
13.67mV
5VSB Ripple (Full Load)
11.00mV
12V Load Regulation
0.53%
5V Load Regulation
0.83%
3.3V Load Regulation
1.14%
5VSB Load Regulation
3.54%
Inrush Current
79.143A
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
21.78
AC Loss to PWR_OK Hold Up Time (ms)
18.44
PWR_OK Inactive to DC Loss Delay (ms)
3.34
待機電源消耗
Tables 115V
Graphs 115V
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.041A
0.213
54.337%
0.029
5.145V
0.392
115.16V
2
0.087A
0.447
65.929%
0.049
5.143V
0.678
115.17V
3
0.542A
2.777
76.145%
0.214
5.126V
3.647
115.13V
4
1.002A
5.118
77.463%
0.300
5.109V
6.607
115.14V
5
1.502A
7.643
77.720%
0.350
5.090V
9.834
115.15V
6
3.001A
15.085
76.218%
0.417
5.026V
19.792
115.15V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.900A
1.985A
1.984A
0.981A
44.763
80.203%
0
<6.0
45.56°C
0.911
12.195V
5.039V
3.322V
5.095V
55.812
38.04°C
115.19V
2
4.830A
2.970A
2.980A
1.181A
89.732
85.002%
1005
20.9
38.75°C
0.968
12.192V
5.035V
3.319V
5.081V
105.564
40.79°C
115.18V
3
8.107A
3.478A
3.496A
1.380A
134.893
86.183%
1005
20.9
38.91°C
0.980
12.188V
5.031V
3.316V
5.068V
156.519
40.97°C
115.19V
4
11.375A
3.976A
3.980A
1.580A
179.732
86.829%
1005
20.9
39.19°C
0.986
12.182V
5.028V
3.313V
5.054V
206.996
41.74°C
115.18V
5
14.314A
4.976A
4.981A
1.785A
224.761
86.641%
1276
29.0
39.70°C
0.990
12.176V
5.023V
3.310V
5.038V
259.417
42.38°C
115.18V
6
17.252A
5.977A
5.985A
1.990A
269.746
86.424%
1315
30.4
40.40°C
0.991
12.170V
5.019V
3.307V
5.024V
312.119
43.12°C
115.18V
7
20.199A
6.986A
6.993A
2.195A
314.762
85.731%
1462
34.3
41.48°C
0.993
12.162V
5.013V
3.302V
5.007V
367.152
44.33°C
115.17V
8
23.151A
7.988A
8.008A
2.400A
359.739
85.056%
1584
35.9
42.61°C
0.993
12.153V
5.009V
3.296V
4.991V
422.943
45.57°C
115.17V
9
26.534A
8.491A
8.536A
2.405A
404.808
84.253%
1667
38.1
43.85°C
0.993
12.144V
5.005V
3.291V
4.985V
480.472
47.08°C
115.17V
10
29.666A
9.009A
9.039A
3.025A
449.689
83.325%
1817
42.0
45.47°C
0.994
12.134V
5.000V
3.285V
4.953V
539.682
48.76°C
115.18V
11
33.397A
9.014A
9.051A
3.030A
494.676
82.329%
1945
42.1
46.33°C
0.994
12.125V
4.997V
3.282V
4.947V
600.854
49.83°C
115.17V
CL1
0.099A
13.019A
13.005A
0.004A
109.380
79.493%
1425
32.3
43.02°C
0.977
12.175V
5.016V
3.295V
5.106V
137.597
45.80°C
115.19V
CL2
37.474A
1.004A
1.002A
1.002A
468.254
84.034%
1817
42.0
44.77°C
0.994
12.138V
5.013V
3.297V
5.049V
557.221
47.98°C
115.18V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.194A
0.493A
0.477A
0.191A
19.626
69.527%
0
<6.0
0.770
12.204V
5.045V
3.324V
5.135V
28.228
115.18V
2
2.415A
0.992A
0.990A
0.391A
39.755
80.129%
0
<6.0
0.895
12.199V
5.042V
3.323V
5.123V
49.614
115.18V
3
3.643A
1.477A
1.503A
0.585A
59.843
82.694%
0
<6.0
0.941
12.193V
5.039V
3.321V
5.111V
72.367
115.18V
4
4.858A
1.986A
1.983A
0.781A
79.786
85.571%
0
<6.0
0.967
12.190V
5.036V
3.320V
5.099V
93.239
115.18V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.3 mV
5.0 mV
6.7 mV
4.7 mV
Pass
20% Load
7.9 mV
5.2 mV
8.1 mV
5.2 mV
Pass
30% Load
7.9 mV
5.9 mV
7.9 mV
5.5 mV
Pass
40% Load
8.4 mV
6.3 mV
8.3 mV
5.8 mV
Pass
50% Load
14.0 mV
6.3 mV
9.2 mV
5.9 mV
Pass
60% Load
10.5 mV
7.3 mV
10.4 mV
6.6 mV
Pass
70% Load
16.0 mV
7.8 mV
14.8 mV
10.7 mV
Pass
80% Load
10.9 mV
7.6 mV
12.9 mV
7.7 mV
Pass
90% Load
11.9 mV
7.4 mV
13.6 mV
7.7 mV
Pass
100% Load
11.8 mV
9.5 mV
13.5 mV
10.4 mV
Pass
110% Load
11.8 mV
9.3 mV
13.7 mV
11.0 mV
Pass
Crossload 1
9.3 mV
7.4 mV
7.9 mV
8.6 mV
Pass
Crossload 2
11.1 mV
8.6 mV
12.4 mV
9.3 mV
Pass
The results above are not used in the certification process