ErP Lot 3/6 2010: ✓
ErP Lot 3/6 2013: ✓
ErP Lot 3/6 2014, CEC: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary 115V
效率評比
PLATINUM
噪音評比
A++
Average Efficiency (>1450 load combinations)
90.337%
Average Noise Output (>1450 Load Combinations)
13.45dBA
Average PF (>1450 Load Combinations)
0.979
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.0987W
12V Ripple (Full Load)
22.38mV
5V Ripple (Full Load)
0.00mV
3.3V Ripple (Full Load)
0.00mV
5VSB Ripple (Full Load)
27.13mV
12V Load Regulation
0.49%
5V Load Regulation
0.00%
3.3V Load Regulation
0.00%
5VSB Load Regulation
2.39%
Inrush Current
31.657A
Hold-Up Time & Power Ok Signal
待機電源消耗
Tables 115V
Graphs 115V
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 115V
The results above are not used in the certification process
Light Load Tests 115V
The results above are not used in the certification process
Ripple Measurements 115V
The results above are not used in the certification process