ErP Lot 3/6 2010: ✓
ErP Lot 3/6 2013: ✓
ErP Lot 3/6 2014, CEC: Partially
符合(EU) No 617/2013规范
✓
Performance Summary 115V
Accredited
平均效率 (>1450 load combinations)
90.337%
Average Noise Output (>1450 Load Combinations)
13.45dBA
PF平均值 (>1450 Load Combinations)
0.979
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
待机功率耗损
0.0987W
Non-Accredited
12V Ripple (Full Load)
22.38mV
5V Ripple (Full Load)
-
3.3V Ripple (Full Load)
-
5VSB Ripple (Full Load)
27.13mV
12V Load Regulation
0.49%
5V Load Regulation
-
3.3V Load Regulation
-
5VSB Load Regulation
2.39%
Inrush Current
31.657A
保持时间 & PG信号
待机电源
Tables 115V
Graphs 115V
转换效率图表
115V
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
噪音值图表
115V
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC) 115V
Protection Features
Supplementary Tests (For Reference)
10-110%负载测试 115V
The results above are not used in the certification process
20-80瓦负载测试 115V
The results above are not used in the certification process
纹波测量 115V