Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
ATX connector 20+4 pin (600mm)
1
1
16-20AWG
8 pin EPS12V (700mm)
1
1
16AWG
4+4 pin EPS12V (700mm)
1
1
16AWG
6+2 pin PCIe (600mm+150mm) / 6+2 pin PCIe (600mm)
2 / 2
4 / 2
18AWG
SATA (600mm+150mm+150mm+150)
2
8
18AWG
SATA (600mm+150mm) / 4 pin Molex (+150mm+150mm)
1
2 / 2
18AWG
4 pin Molex (600mm+150mm+150mm+150mm)
1
4
18AWG
FDD Adapter (+200mm)
1
1
20AWG
GRB DC Adapter (720mm+110mm)
1
2
28AWG
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
20
20
62
3
0.5
Watts
120
744
15
6
Total Max. Power (W)
750
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
ErP Lot 3/6 2010: ✓
ErP Lot 3/6 2013: ✓
ErP Lot 3/6 2014, CEC: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
90.579%
Average Noise Output (>1450 Load Combinations)
17.22dBA
Average PF (>1450 Load Combinations)
0.988
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.0727W
Non-Accredited
12V Ripple (Full Load)
24.52mV
5V Ripple (Full Load)
12.30mV
3.3V Ripple (Full Load)
13.17mV
5VSB Ripple (Full Load)
22.95mV
12V Load Regulation
0.61%
5V Load Regulation
0.61%
3.3V Load Regulation
0.87%
5VSB Load Regulation
1.82%
Inrush Current
37.526A
Accredited
Average Efficiency (>1450 load combinations)
92.214%
Average Noise Output (>1450 Load Combinations)
16.21dBA
Average PF (>1450 Load Combinations)
0.953
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1312W
Non-Accredited
12V Ripple (Full Load)
22.50mV
5V Ripple (Full Load)
11.02mV
3.3V Ripple (Full Load)
15.41mV
5VSB Ripple (Full Load)
22.48mV
12V Load Regulation
0.53%
5V Load Regulation
0.45%
3.3V Load Regulation
0.87%
5VSB Load Regulation
1.76%
Inrush Current
51.932A
Hold-Up Time & PWR_OK Signal
17.90ms
AC Loss to PWR_OK Hold Up Time
15.60ms
PWR_OK Inactive to DC Loss Delay
2.30ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
17.9
AC Loss to PWR_OK Hold Up Time (ms)
15.6
PWR_OK Inactive to DC Loss Delay (ms)
2.3
Stromverbrauch im Ruhezustand
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.041A
0.207
64.486%
0.025
5.031V
0.321
115.21V
2
0.086A
0.435
72.379%
0.047
5.030V
0.601
115.21V
3
0.541A
2.713
80.029%
0.222
5.013V
3.390
115.20V
4
1.001A
5.003
80.929%
0.323
4.997V
6.182
115.20V
5
1.501A
7.475
80.290%
0.386
4.980V
9.310
115.20V
6
3.001A
14.786
77.809%
0.467
4.927V
19.003
115.20V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.041A
0.207
55.200%
0.009
5.031V
0.375
230.48V
2
0.087A
0.435
65.120%
0.016
5.029V
0.668
230.48V
3
0.541A
2.713
74.738%
0.083
5.011V
3.630
230.48V
4
1.001A
5.003
78.874%
0.138
4.996V
6.343
230.48V
5
1.501A
7.473
79.306%
0.192
4.979V
9.423
230.47V
6
3.001A
14.782
78.328%
0.301
4.926V
18.872
230.48V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.359A
1.954A
1.968A
0.980A
74.725
88.784%
0
| 6
42.31°C
0.966
12.194V
5.115V
3.351V
5.084V
84.165
38.14°C
115.21V
2
9.747A
2.929A
2.954A
1.180A
149.704
92.985%
0
| 6
43.41°C
0.983
12.194V
5.110V
3.348V
5.078V
160.998
38.57°C
115.20V
3
15.490A
3.427A
3.464A
1.379A
224.837
93.174%
0
| 6
43.71°C
0.985
12.186V
5.106V
3.345V
5.070V
241.309
38.74°C
115.20V
4
21.229A
3.915A
3.946A
1.579A
299.693
92.840%
0
| 6
44.08°C
0.985
12.178V
5.104V
3.343V
5.062V
322.805
39.01°C
115.20V
5
26.641A
4.907A
4.938A
1.780A
374.731
92.356%
0
| 6
44.68°C
0.990
12.170V
5.099V
3.340V
5.054V
405.745
39.46°C
115.21V
6
32.052A
5.884A
5.932A
1.979A
449.588
91.163%
395
6.5
40.82°C
0.992
12.162V
5.097V
3.336V
5.049V
493.171
48.60°C
115.21V
7
37.479A
6.874A
6.931A
2.180A
524.590
90.559%
395
6.5
41.67°C
0.993
12.153V
5.094V
3.333V
5.042V
579.283
49.83°C
115.22V
8
42.915A
7.860A
7.929A
2.380A
599.557
89.664%
1025
27.8
43.08°C
0.994
12.144V
5.091V
3.329V
5.036V
668.674
51.35°C
115.22V
9
48.782A
8.357A
8.446A
2.380A
674.605
89.004%
1045
28.2
43.81°C
0.995
12.136V
5.088V
3.325V
5.035V
757.945
52.33°C
115.22V
10
54.404A
8.855A
8.933A
2.991A
749.443
88.191%
1045
28.2
45.08°C
0.996
12.127V
5.084V
3.323V
5.009V
849.795
54.30°C
115.22V
11
60.611A
8.861A
8.940A
2.995A
824.307
87.446%
1045
28.2
46.19°C
0.996
12.120V
5.081V
3.321V
5.005V
942.652
56.50°C
115.22V
CL1
0.098A
14.029A
14.004A
0.000A
119.418
86.951%
395
6.5
44.44°C
0.977
12.196V
5.097V
3.336V
5.154V
137.339
52.98°C
115.22V
CL2
61.934A
1.004A
1.001A
1.001A
764.956
88.462%
1045
28.2
45.68°C
0.996
12.133V
5.091V
3.332V
5.060V
864.731
54.39°C
115.22V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.365A
1.953A
1.966A
0.981A
74.804
88.602%
0
<6.0
46.10°C
0.824
12.197V
5.115V
3.350V
5.084V
84.427
38.93°C
365.12V
2
9.749A
2.927A
2.954A
1.181A
149.781
93.280%
0
<6.0
47.56°C
0.919
12.199V
5.113V
3.348V
5.078V
160.572
39.66°C
230.24V
3
15.489A
3.425A
3.466A
1.380A
224.912
94.012%
0
<6.0
48.89°C
0.950
12.191V
5.108V
3.345V
5.071V
239.238
40.63°C
230.23V
4
21.222A
3.911A
3.948A
1.580A
299.748
94.125%
0
<6.0
49.32°C
0.964
12.185V
5.105V
3.343V
5.060V
318.456
40.86°C
230.23V
5
26.632A
4.896A
4.938A
1.780A
374.795
93.626%
395
6.5
41.85°C
0.971
12.178V
5.104V
3.338V
5.055V
400.310
50.78°C
230.22V
6
32.038A
5.879A
5.934A
1.980A
449.678
93.304%
395
6.5
42.03°C
0.977
12.170V
5.101V
3.335V
5.049V
481.947
51.33°C
230.22V
7
37.460A
6.866A
6.931A
2.180A
524.670
92.913%
395
6.5
43.48°C
0.978
12.162V
5.098V
3.331V
5.042V
564.692
53.17°C
230.22V
8
42.881A
7.855A
7.931A
2.380A
599.575
92.177%
1025
27.8
44.80°C
0.980
12.154V
5.096V
3.327V
5.035V
650.457
55.34°C
230.22V
9
48.754A
8.345A
8.454A
2.380A
674.712
91.751%
1025
27.8
45.28°C
0.982
12.145V
5.095V
3.323V
5.035V
735.373
56.12°C
230.23V
10
54.364A
8.838A
8.940A
2.991A
749.549
91.221%
1025
27.8
46.25°C
0.984
12.138V
5.092V
3.321V
5.010V
821.687
57.76°C
230.23V
11
60.566A
8.843A
8.949A
2.994A
824.482
90.735%
1025
27.8
46.93°C
0.985
12.132V
5.090V
3.318V
5.007V
908.669
58.60°C
230.24V
CL1
0.102A
14.025A
14.004A
0.004A
119.662
86.933%
395
6.5
42.49°C
0.906
12.191V
5.105V
3.342V
5.153V
137.648
51.86°C
230.25V
CL2
61.943A
1.000A
1.003A
1.002A
765.866
91.610%
1045
28.2
45.06°C
0.984
12.146V
5.097V
3.326V
5.063V
836.011
55.41°C
230.22V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.193A
0.482A
0.473A
0.195A
19.599
77.155%
0
| 6
0.856
12.201V
5.112V
3.350V
5.102V
25.402
115.21V
2
2.415A
0.967A
0.982A
0.390A
39.685
82.903%
0
| 6
0.929
12.198V
5.115V
3.352V
5.100V
47.869
115.21V
3
3.640A
1.459A
1.487A
0.585A
59.822
87.283%
0
| 6
0.961
12.196V
5.115V
3.352V
5.096V
68.538
115.21V
4
4.849A
1.955A
1.968A
0.785A
79.754
89.683%
0
| 6
0.968
12.202V
5.113V
3.350V
5.092V
88.929
115.21V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.200A
0.480A
0.475A
0.195A
19.682
75.396%
0
<6.0
0.453
12.203V
5.110V
3.349V
5.102V
26.105
230.24V
2
2.418A
0.969A
0.983A
0.391A
39.749
83.561%
0
<6.0
0.671
12.201V
5.116V
3.351V
5.101V
47.569
230.24V
3
3.643A
1.459A
1.489A
0.586A
59.880
87.486%
0
<6.0
0.777
12.199V
5.116V
3.350V
5.097V
68.445
230.24V
4
4.859A
1.952A
1.969A
0.786A
79.847
89.096%
0
<6.0
0.836
12.197V
5.115V
3.350V
5.092V
89.619
230.24V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
9.6 mV
6.4 mV
6.6 mV
8.4 mV
Pass
20% Load
9.1 mV
7.1 mV
7.6 mV
11.4 mV
Pass
30% Load
10.6 mV
7.3 mV
8.0 mV
13.2 mV
Pass
40% Load
12.0 mV
8.8 mV
8.5 mV
14.2 mV
Pass
50% Load
13.9 mV
8.6 mV
11.0 mV
15.0 mV
Pass
60% Load
16.0 mV
9.4 mV
8.6 mV
16.3 mV
Pass
70% Load
17.8 mV
9.6 mV
9.7 mV
17.4 mV
Pass
80% Load
20.1 mV
10.4 mV
11.7 mV
18.9 mV
Pass
90% Load
21.6 mV
11.1 mV
13.6 mV
20.0 mV
Pass
100% Load
24.5 mV
12.3 mV
13.2 mV
23.0 mV
Pass
110% Load
26.7 mV
13.3 mV
13.8 mV
23.9 mV
Pass
Crossload 1
11.5 mV
8.5 mV
9.5 mV
12.0 mV
Pass
Crossload 2
24.8 mV
11.7 mV
12.3 mV
22.3 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.9 mV
5.7 mV
9.5 mV
6.6 mV
Pass
20% Load
10.4 mV
6.8 mV
10.6 mV
9.1 mV
Pass
30% Load
10.7 mV
6.8 mV
10.3 mV
11.6 mV
Pass
40% Load
11.7 mV
6.7 mV
10.7 mV
13.1 mV
Pass
50% Load
13.0 mV
7.6 mV
12.0 mV
14.0 mV
Pass
60% Load
14.8 mV
7.9 mV
12.0 mV
15.8 mV
Pass
70% Load
16.7 mV
8.6 mV
13.3 mV
16.8 mV
Pass
80% Load
19.2 mV
9.4 mV
18.1 mV
18.4 mV
Pass
90% Load
20.5 mV
9.7 mV
17.8 mV
19.9 mV
Pass
100% Load
22.5 mV
11.0 mV
15.4 mV
22.5 mV
Pass
110% Load
24.7 mV
11.5 mV
17.1 mV
23.4 mV
Pass
Crossload 1
25.4 mV
7.4 mV
11.8 mV
8.0 mV
Pass
Crossload 2
22.4 mV
10.1 mV
16.6 mV
21.6 mV
Pass
The results above are not used in the certification process
Aerocool ACP-750FP7
Top side
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern