ErP Lot 3/6 2010: ✓
ErP Lot 3/6 2013: ✓
ErP Lot 3/6 2014, CEC: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary 115V
Accredited
Average Efficiency (>1450 load combinations)
85.300%
Average Noise Output (>1450 Load Combinations)
32.81dBA
Average PF (>1450 Load Combinations)
0.990
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1272W
Non-Accredited
12V Ripple (Full Load)
14.03mV
5V Ripple (Full Load)
18.88mV
3.3V Ripple (Full Load)
19.89mV
5VSB Ripple (Full Load)
24.24mV
12V Load Regulation
0.70%
5V Load Regulation
0.95%
3.3V Load Regulation
1.39%
5VSB Load Regulation
3.80%
Inrush Current
45.351A
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
20.28
AC Loss to PWR_OK Hold Up Time (ms)
17.08
PWR_OK Inactive to DC Loss Delay (ms)
3.20
待機電源消耗
Tables 115V
Graphs 115V
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.041A
0.213
55.181%
0.030
5.141V
0.386
115.16V
2
0.087A
0.447
66.716%
0.051
5.139V
0.670
115.16V
3
0.542A
2.776
76.727%
0.227
5.123V
3.618
115.16V
4
1.002A
5.116
77.917%
0.326
5.107V
6.566
115.16V
5
1.502A
7.643
78.245%
0.385
5.090V
9.768
115.16V
6
3.001A
15.097
76.790%
0.465
5.031V
19.660
115.16V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.210A
1.985A
1.991A
0.980A
84.785
80.878%
0
<6.0
45.75°C
0.954
12.128V
5.047V
3.310V
5.092V
104.831
38.55°C
115.18V
2
11.444A
2.971A
2.992A
1.181A
169.620
85.014%
0
<6.0
43.19°C
0.982
12.125V
5.041V
3.305V
5.076V
199.521
40.50°C
115.18V
3
18.052A
3.478A
3.510A
1.380A
254.853
86.712%
1218
27.3
41.24°C
0.989
12.119V
5.036V
3.300V
5.060V
293.906
47.13°C
115.19V
4
24.648A
3.977A
4.001A
1.584A
339.727
87.533%
1276
29.0
41.29°C
0.992
12.112V
5.032V
3.296V
5.045V
388.113
47.08°C
115.20V
5
30.912A
4.974A
5.009A
1.785A
424.624
87.466%
1338
30.7
41.63°C
0.994
12.104V
5.026V
3.292V
5.029V
485.473
48.15°C
115.22V
6
37.193A
5.977A
6.022A
1.994A
509.607
86.950%
1462
34.3
42.72°C
0.995
12.094V
5.021V
3.287V
5.010V
586.089
49.76°C
115.19V
7
43.502A
6.981A
7.038A
2.199A
594.560
86.345%
1600
36.1
43.47°C
0.996
12.079V
5.017V
3.282V
4.992V
688.583
51.70°C
115.20V
8
49.797A
7.987A
8.058A
2.410A
679.494
85.549%
1743
40.0
44.14°C
0.996
12.071V
5.010V
3.275V
4.975V
794.273
53.88°C
115.18V
9
56.545A
8.488A
8.583A
2.414A
764.493
84.596%
1885
42.2
44.62°C
0.996
12.060V
5.007V
3.271V
4.965V
903.702
54.68°C
115.18V
10
63.031A
9.005A
9.088A
3.036A
849.365
83.782%
1885
42.2
45.71°C
0.997
12.052V
5.002V
3.267V
4.935V
1013.785
56.43°C
115.18V
11
70.143A
9.016A
9.099A
3.042A
934.308
82.482%
2014
43.1
46.20°C
0.997
12.041V
4.997V
3.262V
4.925V
1132.742
56.85°C
115.18V
CL1
0.098A
14.023A
14.004A
0.004A
117.803
77.549%
1432
32.6
44.59°C
0.974
12.123V
5.027V
3.292V
5.107V
151.908
51.67°C
115.20V
CL2
70.778A
1.004A
1.003A
1.002A
865.942
83.783%
2003
43.0
47.16°C
0.996
12.046V
5.011V
3.278V
5.022V
1033.550
56.62°C
115.18V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.200A
0.493A
0.478A
0.192A
19.629
62.453%
0
<6.0
0.834
12.141V
5.052V
3.315V
5.130V
31.430
115.18V
2
2.428A
0.987A
0.994A
0.391A
39.749
75.220%
0
<6.0
0.933
12.137V
5.050V
3.313V
5.121V
52.844
115.18V
3
3.662A
1.477A
1.508A
0.585A
59.870
78.364%
0
<6.0
0.937
12.133V
5.048V
3.312V
5.110V
76.400
115.18V
4
4.881A
1.985A
1.990A
0.781A
79.789
80.384%
0
<6.0
0.951
12.129V
5.047V
3.310V
5.099V
99.260
115.18V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
5.9 mV
9.0 mV
9.0 mV
12.5 mV
Pass
20% Load
7.6 mV
9.4 mV
9.7 mV
13.4 mV
Pass
30% Load
8.9 mV
11.2 mV
11.2 mV
13.7 mV
Pass
40% Load
8.8 mV
11.3 mV
13.1 mV
13.6 mV
Pass
50% Load
10.0 mV
11.1 mV
13.7 mV
14.3 mV
Pass
60% Load
10.9 mV
11.7 mV
15.0 mV
15.7 mV
Pass
70% Load
10.7 mV
13.5 mV
14.7 mV
16.9 mV
Pass
80% Load
11.9 mV
14.7 mV
17.2 mV
20.0 mV
Pass
90% Load
11.8 mV
17.8 mV
19.5 mV
18.7 mV
Pass
100% Load
14.0 mV
18.9 mV
19.9 mV
24.2 mV
Pass
110% Load
14.2 mV
20.2 mV
20.6 mV
25.8 mV
Pass
Crossload 1
7.8 mV
10.7 mV
11.1 mV
14.6 mV
Pass
Crossload 2
12.9 mV
17.1 mV
19.6 mV
21.3 mV
Pass
The results above are not used in the certification process