CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
NZXT NP-C850M
Serial Number31195125400201
Lab IDNZ85001672
Certification ID251672
  • Test Result Report ID: 20PS1672A
  • Certificate Issue Date: Jul 10, 2020
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Vampire Power

Tables

Graphs

Efficiency Graph

Noise Graph

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 45.2 °C0 RPM · <6.0 dB(A) · 45.2 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 46.2 °C0 RPM · <6.0 dB(A) · 46.2 °Cfan off in both
50%557 RPM · 9.9 dB(A) · 42.0 °C557 RPM · 9.9 dB(A) · 42.0 °C+0.0 dB(A)
100%2086 RPM · 44.6 dB(A) · 45.5 °C2086 RPM · 44.6 dB(A) · 45.5 °C+0.0 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 44.3 °C0 RPM · <6.0 dB(A) · 44.3 °Cfan off in both
20%533 RPM · 9.4 dB(A) · 40.8 °C533 RPM · 9.4 dB(A) · 40.8 °C+0.0 dB(A)
50%560 RPM · 10.0 dB(A) · 42.6 °C560 RPM · 10.0 dB(A) · 42.6 °C+0.0 dB(A)
100%2095 RPM · 44.7 dB(A) · 45.8 °C2095 RPM · 44.7 dB(A) · 45.8 °C+0.0 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter, with the fan stopped; with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

NZXT NP-C850M

Top side
Top side
Power specifications label
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics runs voluntary certification programs for power supplies - ETA for efficiency, LAMBDA for noise and SAFE for safety and correct operation - and for cooling products, with DELTA for chassis soundproofing and PHI for fan airflow and static pressure. THETA rates cooler performance on AMD AM5 and Intel LGA1851 outside ISO 17065 and accreditation scope
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus