CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Corsair CX650
Serial Number19214855000036630128
Lab IDCR65001684
Certification ID251684
  • Test Result Report ID: 20PS1684A
  • Certificate Issue Date: Jul 16, 2020
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

待機電源消耗

Tables

Graphs

Efficiency Graph

Noise Graph

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%1024 RPM · 22.4 dB(A) · 33.9 °C1024 RPM · 22.4 dB(A) · 33.9 °C+0.0 dB(A)
20%1106 RPM · 25.1 dB(A) · 34.9 °C1106 RPM · 25.1 dB(A) · 34.9 °C+0.0 dB(A)
50%1357 RPM · 31.2 dB(A) · 36.1 °C1357 RPM · 31.2 dB(A) · 36.1 °C+0.0 dB(A)
100%1810 RPM · 39.6 dB(A) · 39.2 °C1810 RPM · 39.6 dB(A) · 39.2 °C+0.0 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%1005 RPM · 21.7 dB(A) · 34.5 °C1005 RPM · 21.7 dB(A) · 34.5 °C+0.0 dB(A)
20%1068 RPM · 23.6 dB(A) · 35.0 °C1068 RPM · 23.6 dB(A) · 35.0 °C+0.0 dB(A)
50%1383 RPM · 32.0 dB(A) · 36.3 °C1383 RPM · 32.0 dB(A) · 36.3 °C+0.0 dB(A)
100%1815 RPM · 39.7 dB(A) · 39.2 °C1815 RPM · 39.7 dB(A) · 39.2 °C+0.0 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

Corsair CX650

Top side
Top side
Power specifications label
Power specifications label
Cybenetics 提供自願性認證方案:電源供應器方面有 ETA(效率)、LAMBDA(噪音)與 SAFE(安全與正確運作);散熱產品方面有 DELTA(機殼隔音)與 PHI(風扇風量與靜壓)
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus