Cables and Connectors(Non-accredited measurements)
Native Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Caps
ATX connector 20+4 pin (520mm)
1
1
18-22AWG
No
4+4 pin EPS12V (620mm)
1
1
18AWG
No
6+2 pin PCIe (520mm+150mm)
1
2
18-20AWG
No
SATA (530mm+150mm+150mm) / 4-pin Molex (+150mm)
2
4 / 2
18-20AWG
No
SATA (530mm) / 4-pin Molex (+150mm+150mm)
1
1 / 2
18-20AWG
No
SATA (530mm) / 4-pin Molex (+150mm) / FDD(+150mm)
1
1 / 1 / 1
18-22AWG
No
Modular Cables
AC Power Cord (1380mm) - C13 coupler
1
1
18AWG
-
Protection Features(Manufacturer)
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
24
17
54
2.5
0.5
Watts
120
648
12.5
6
Total Max. Power (W)
700
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary 230V
Accredited
Average Efficiency (>1450 load combinations)
84.403%
Average Noise Output (>1450 Load Combinations)
40.45dBA
Average PF (>1450 Load Combinations)
0.959
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1387W
Non-Accredited
12V Ripple (Full Load)
45.97mV
5V Ripple (Full Load)
20.60mV
3.3V Ripple (Full Load)
25.67mV
5VSB Ripple (Full Load)
34.01mV
12V Load Regulation
3.18%
5V Load Regulation
2.53%
3.3V Load Regulation
3.58%
5VSB Load Regulation
4.36%
Inrush Current
80.990A
Hold-Up Time & Power Ok Signal
12.50ms
AC Loss to PWR_OK Hold Up Time
12.60ms
PWR_OK Inactive to DC Loss Delay
-0.10ms
PSU Timings: T1 (20% / 100%)
50.0ms
52.0ms
PSU Timings: T3 (20% / 100%)
295.0ms
295.0ms
OPP (0.00°C / 0.00°C)
114.01%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
12.5
AC Loss to PWR_OK Hold Up Time (ms)
12.6
PWR_OK Inactive to DC Loss Delay (ms)
-0.1
待機電源消耗
Tables 230V
Graphs 230V
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232
54.717%
0.026
5.156V
0.424
230.37V
2
0.090A
0.464
65.077%
0.043
5.155V
0.713
230.37V
3
0.550A
2.830
76.881%
0.182
5.144V
3.681
230.36V
4
1.000A
5.134
77.930%
0.256
5.133V
6.588
230.36V
5
1.500A
7.683
78.518%
0.300
5.121V
9.785
230.36V
6
2.501A
12.743
78.025%
0.346
5.096V
16.332
230.36V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.003A
1.937A
1.954A
0.978A
70.008
80.904%
1034
28.8
34.97°C
0.893
12.092V
5.164V
3.378V
5.114V
86.532
36.80°C
230.39V
2
9.049A
2.914A
2.943A
1.178A
140.050
85.891%
1141
31.5
35.33°C
0.934
12.061V
5.150V
3.365V
5.093V
163.055
37.48°C
230.39V
3
14.489A
3.404A
3.442A
1.380A
210.056
87.293%
1332
35.6
36.76°C
0.948
12.009V
5.144V
3.354V
5.074V
240.633
39.23°C
230.40V
4
19.974A
3.895A
3.949A
1.583A
280.061
87.500%
1472
38.5
36.86°C
0.956
11.958V
5.137V
3.343V
5.054V
320.068
39.86°C
230.38V
5
25.109A
4.883A
4.955A
1.789A
350.060
87.174%
1612
40.6
37.08°C
0.962
11.930V
5.121V
3.330V
5.033V
401.566
40.89°C
230.38V
6
30.264A
5.878A
5.970A
1.997A
420.017
86.542%
1756
42.8
38.23°C
0.965
11.902V
5.105V
3.317V
5.010V
485.335
42.31°C
230.36V
7
35.480A
6.878A
6.992A
2.207A
490.152
85.694%
1879
44.3
38.76°C
0.969
11.867V
5.089V
3.304V
4.987V
571.982
43.34°C
230.38V
8
40.733A
7.888A
8.027A
2.419A
560.290
84.766%
1892
44.6
39.01°C
0.972
11.830V
5.073V
3.289V
4.962V
660.988
44.51°C
230.38V
9
46.517A
8.393A
8.546A
2.429A
630.016
83.731%
1894
44.7
39.27°C
0.975
11.770V
5.065V
3.276V
4.942V
752.431
45.39°C
230.34V
10
52.367A
8.905A
9.107A
2.542A
700.338
82.567%
1881
44.4
39.44°C
0.978
11.708V
5.056V
3.261V
4.919V
848.210
46.47°C
230.35V
11
58.722A
8.905A
9.142A
2.551A
769.981
81.099%
1882
44.4
40.61°C
0.981
11.627V
5.055V
3.249V
4.901V
949.432
48.53°C
230.41V
CL1
0.119A
14.001A
14.000A
0.002A
114.803
74.553%
2010
45.9
37.47°C
0.938
13.309V
4.748V
3.338V
5.081V
153.988
41.06°C
230.37V
CL2
54.020A
1.000A
1.000A
1.000A
619.765
83.657%
1836
43.6
39.65°C
0.975
11.222V
5.255V
3.295V
5.002V
740.840
46.81°C
230.35V
The results above are not used in the certification process
Light Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.227A
0.482A
0.487A
0.194A
19.996
66.731%
1030
28.7
0.731
12.101V
5.184V
3.391V
5.147V
29.965
230.38V
2
2.456A
0.965A
0.972A
0.390A
39.987
76.808%
1026
28.5
0.829
12.090V
5.179V
3.387V
5.137V
52.061
230.38V
3
3.690A
1.449A
1.465A
0.585A
60.017
80.065%
1025
28.5
0.877
12.078V
5.174V
3.381V
5.127V
74.960
230.38V
4
4.916A
1.935A
1.954A
0.782A
79.967
82.573%
1038
29.0
0.904
12.077V
5.166V
3.377V
5.117V
96.844
230.38V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
9.10mV
4.60mV
6.70mV
6.00mV
Pass
20% Load
11.10mV
5.10mV
7.30mV
6.60mV
Pass
30% Load
13.00mV
5.70mV
7.50mV
7.70mV
Pass
40% Load
14.10mV
6.70mV
8.00mV
8.60mV
Pass
50% Load
16.60mV
8.30mV
9.80mV
9.60mV
Pass
60% Load
22.00mV
9.00mV
9.90mV
10.10mV
Pass
70% Load
24.10mV
10.40mV
9.90mV
15.90mV
Pass
80% Load
27.70mV
11.40mV
18.50mV
21.20mV
Pass
90% Load
32.40mV
14.70mV
21.70mV
29.90mV
Pass
100% Load
46.00mV
20.60mV
25.70mV
34.00mV
Pass
110% Load
53.90mV
22.10mV
29.20mV
43.70mV
Pass
Crossload1
13.80mV
75.30mV
23.70mV
16.70mV
Fail
Crossload2
45.60mV
12.60mV
18.20mV
17.00mV
Pass
The results above are not used in the certification process