This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
转换效率图表
230V
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
噪音值图表
230V
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC) 230V
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.045A
0.227
59.269%
0.025
5.041V
0.383
230.28V
2
0.090A
0.454
67.560%
0.043
5.041V
0.672
230.29V
3
0.550A
2.768
76.996%
0.189
5.033V
3.595
230.30V
4
1.000A
5.025
77.895%
0.268
5.025V
6.451
230.31V
5
1.500A
7.525
78.068%
0.317
5.017V
9.639
230.29V
6
2.500A
12.498
78.269%
0.365
5.000V
15.968
230.29V
Protection Features
Supplementary Tests (For Reference)
10-110%负载测试 230V
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
温度(输入/输出)
PF/AC 电压
1
1.542A
1.969A
1.953A
0.998A
39.986
73.119%
1433
36.5
30.14°C
0.832
11.927V
5.080V
3.375V
5.012V
54.686
34.15°C
230.29V
2
4.115A
2.957A
2.944A
1.201A
80.009
80.797%
1576
39.2
31.04°C
0.923
11.934V
5.073V
3.362V
4.997V
99.025
35.59°C
230.28V
3
7.037A
3.448A
3.447A
1.405A
119.938
83.718%
1577
39.2
31.11°C
0.953
11.921V
5.075V
3.351V
4.983V
143.265
36.29°C
230.27V
4
9.974A
3.937A
3.952A
1.609A
159.969
84.813%
1738
42.3
31.90°C
0.967
11.909V
5.078V
3.340V
4.970V
188.614
37.65°C
230.26V
5
12.540A
4.933A
4.961A
1.816A
199.988
85.057%
1834
43.1
32.51°C
0.975
11.921V
5.068V
3.326V
4.955V
235.123
38.82°C
230.26V
6
15.094A
5.931A
5.975A
2.000A
239.811
85.016%
1934
45.2
32.93°C
0.980
11.934V
5.059V
3.313V
4.940V
282.076
39.49°C
230.26V
7
17.656A
6.932A
7.002A
2.233A
279.991
84.757%
2028
46.6
33.56°C
0.983
11.944V
5.050V
3.300V
4.924V
330.344
40.85°C
230.25V
8
20.209A
7.938A
8.034A
2.444A
319.971
84.345%
2108
46.0
34.09°C
0.986
11.954V
5.040V
3.285V
4.907V
379.359
42.10°C
230.25V
9
23.229A
8.428A
8.548A
2.450A
359.901
84.035%
2147
47.0
34.39°C
0.987
11.943V
5.042V
3.274V
4.897V
428.276
43.26°C
230.26V
10
26.219A
8.920A
9.102A
2.559A
399.971
83.556%
2188
47.9
35.24°C
0.988
11.930V
5.044V
3.262V
4.883V
478.684
44.51°C
230.26V
11
29.646A
8.899A
9.129A
2.564A
439.826
83.102%
2193
48.0
35.70°C
0.989
11.895V
5.057V
3.252V
4.874V
529.261
45.55°C
230.25V
CL1
3.999A
14.001A
13.998A
0.000A
163.588
78.458%
2086
47.2
32.40°C
0.971
12.344V
4.862V
3.297V
4.960V
208.504
38.54°C
230.27V
CL2
30.000A
0.999A
1.000A
1.000A
359.918
85.106%
1992
45.7
35.86°C
0.987
11.548V
5.236V
3.305V
4.942V
422.907
44.81°C
230.27V
The results above are not used in the certification process
20-80瓦负载测试 230V
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
PF/AC 电压
1
1.255A
0.486A
0.486A
0.199A
19.980
64.472%
1083
28.1
0.688
11.824V
5.131V
3.386V
5.033V
30.990
230.30V
2
2.505A
0.977A
0.975A
0.398A
39.969
74.916%
1293
33.6
0.826
11.846V
5.119V
3.379V
5.024V
53.352
230.30V
3
3.755A
1.468A
1.466A
0.598A
60.000
79.889%
1174
30.8
0.889
11.866V
5.108V
3.373V
5.015V
75.104
230.30V
4
4.997A
1.960A
1.960A
0.799A
79.950
82.184%
1238
32.1
0.921
11.878V
5.100V
3.367V
5.006V
97.282
230.29V
The results above are not used in the certification process
纹波测量 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
23.00mV
16.00mV
8.20mV
12.60mV
Pass
20% Load
25.30mV
14.50mV
8.30mV
45.50mV
Pass
30% Load
26.30mV
15.30mV
8.60mV
13.20mV
Pass
40% Load
27.30mV
15.40mV
9.10mV
13.50mV
Pass
50% Load
29.90mV
16.60mV
9.90mV
13.40mV
Pass
60% Load
32.50mV
17.10mV
10.60mV
13.40mV
Pass
70% Load
35.60mV
19.40mV
11.50mV
14.10mV
Pass
80% Load
40.80mV
21.50mV
16.80mV
13.70mV
Pass
90% Load
43.20mV
27.30mV
17.90mV
42.90mV
Pass
100% Load
61.10mV
32.90mV
19.40mV
15.50mV
Pass
110% Load
61.40mV
35.10mV
20.50mV
15.80mV
Pass
Crossload1
44.10mV
29.00mV
18.30mV
14.00mV
Pass
Crossload2
50.30mV
24.40mV
13.80mV
16.10mV
Pass
The results above are not used in the certification process