Cables and Connectors(Non-accredited measurements)
Captive Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (360mm)
1
1
18-22AWG
No
4+4 pin EPS12V (400mm)
1
1
18-20AWG
No
6+2 pin PCIe (500mm+110mm)
1
2
18-20AWG
No
SATA (300mm+150mm) / 4-pin Molex (+150mm)
2
4 / 2
20AWG
No
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
21
22
36
3
0.5
Watts
120
432
15
6
Total Max. Power (W)
450
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
ErP Lot 6 2010: ✓
ErP Lot 6 2013: ✓
ErP Lot 3 2014 & CEC: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary 230V
Accredited
Average Efficiency (>1450 load combinations)
83.902%
Average Noise Output (>1450 Load Combinations)
38.31dBA
Average PF (>1450 Load Combinations)
0.979
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.2288W
Non-Accredited
12V Ripple (Full Load)
66.32mV
5V Ripple (Full Load)
33.44mV
3.3V Ripple (Full Load)
30.03mV
5VSB Ripple (Full Load)
24.71mV
12V Load Regulation
1.79%
5V Load Regulation
2.76%
3.3V Load Regulation
2.51%
5VSB Load Regulation
3.75%
Inrush Current
73.800A
Hold-Up Time & PWR_OK Signal
7.70ms
AC Loss to PWR_OK Hold Up Time
24.90ms
PWR_OK Inactive to DC Loss Delay
-17.20ms
PSU Timings: T1 (20% / 100%)
56.0ms
56.0ms
PSU Timings: T3 (20% / 100%)
284.0ms
284.0ms
OPP (27.40°C / 0.00°C)
126.68%
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
7.7
AC Loss to PWR_OK Hold Up Time (ms)
24.9
PWR_OK Inactive to DC Loss Delay (ms)
-17.2
待機電源消耗
Tables 230V
Graphs 230V
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232
52.135%
0.029
5.159V
0.445
230.35V
2
0.090A
0.464
61.053%
0.049
5.157V
0.760
230.35V
3
0.550A
2.827
73.697%
0.202
5.139V
3.836
230.35V
4
1.000A
5.121
76.251%
0.286
5.120V
6.716
230.34V
5
1.500A
7.662
77.160%
0.337
5.107V
9.930
230.34V
6
3.000A
15.049
75.913%
0.406
5.016V
19.824
230.34V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.948A
1.956A
1.973A
0.977A
44.957
78.679%
950
11.2
30.71°C
0.872
11.989V
5.113V
3.345V
5.118V
57.140
35.15°C
230.38V
2
4.938A
2.942A
2.966A
1.176A
90.015
84.170%
1064
13.2
31.08°C
0.946
11.973V
5.098V
3.336V
5.101V
106.944
36.16°C
230.39V
3
8.288A
3.436A
3.471A
1.376A
135.012
85.934%
1380
20.4
31.63°C
0.967
11.940V
5.094V
3.328V
5.086V
157.112
37.56°C
230.40V
4
11.658A
3.929A
3.976A
1.577A
180.006
86.564%
1607
25.4
32.38°C
0.977
11.907V
5.090V
3.319V
5.073V
207.945
38.91°C
230.40V
5
14.670A
4.930A
4.983A
1.780A
224.999
86.417%
2019
31.7
32.88°C
0.983
11.895V
5.072V
3.310V
5.057V
260.363
40.28°C
230.39V
6
17.688A
5.937A
6.000A
1.985A
269.985
86.043%
2260
35.0
33.09°C
0.986
11.882V
5.055V
3.300V
5.040V
313.779
41.19°C
230.38V
7
20.722A
6.947A
7.021A
2.191A
315.056
85.501%
2515
37.9
33.99°C
0.986
11.869V
5.038V
3.291V
5.021V
368.482
42.65°C
230.37V
8
23.748A
7.968A
8.040A
2.404A
360.022
84.860%
2628
39.1
34.83°C
0.987
11.859V
5.021V
3.282V
4.992V
424.253
43.96°C
230.36V
9
27.289A
8.469A
8.553A
2.404A
404.851
84.142%
2903
42.9
35.47°C
0.987
11.813V
5.017V
3.273V
4.993V
481.151
45.43°C
230.35V
10
30.575A
8.980A
9.096A
3.029A
449.680
83.224%
3082
45.5
35.72°C
0.987
11.774V
5.011V
3.264V
4.953V
540.326
46.89°C
230.36V
11
34.574A
8.964A
9.118A
3.032A
494.508
82.405%
3121
46.1
36.02°C
0.986
11.709V
5.019V
3.256V
4.948V
600.095
47.87°C
230.34V
CL1
4.000A
14.000A
14.000A
0.000A
163.252
79.886%
2667
40.1
33.26°C
0.977
12.372V
4.830V
3.296V
5.093V
204.356
40.76°C
230.39V
CL2
36.004A
2.001A
1.999A
1.000A
433.323
84.028%
2780
40.5
35.68°C
0.987
11.423V
5.211V
3.287V
5.051V
515.688
45.62°C
230.35V
The results above are not used in the certification process
Light Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.243A
0.485A
0.493A
0.194A
19.986
69.204%
870
10.0
0.600
11.933V
5.156V
3.355V
5.149V
28.880
230.41V
2
2.486A
0.973A
0.984A
0.389A
39.975
79.093%
919
9.9
0.848
11.936V
5.145V
3.350V
5.139V
50.542
230.39V
3
3.733A
1.460A
1.480A
0.585A
60.004
82.677%
927
10.3
0.908
11.936V
5.134V
3.345V
5.129V
72.576
230.39V
4
4.972A
1.952A
1.978A
0.781A
79.953
84.468%
941
11.1
0.938
11.936V
5.124V
3.340V
5.119V
94.655
230.39V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
32.70mV
17.60mV
21.50mV
16.30mV
Pass
20% Load
34.60mV
18.20mV
20.60mV
16.60mV
Pass
30% Load
35.60mV
18.00mV
20.30mV
16.80mV
Pass
40% Load
37.30mV
19.00mV
21.30mV
17.00mV
Pass
50% Load
37.20mV
19.30mV
20.60mV
17.00mV
Pass
60% Load
35.80mV
18.50mV
20.70mV
16.70mV
Pass
70% Load
34.20mV
18.40mV
20.90mV
17.40mV
Pass
80% Load
35.00mV
17.80mV
24.90mV
19.10mV
Pass
90% Load
35.80mV
18.00mV
22.80mV
18.50mV
Pass
100% Load
66.30mV
33.40mV
30.00mV
24.70mV
Pass
110% Load
70.10mV
34.40mV
27.90mV
25.70mV
Pass
Crossload1
58.80mV
29.50mV
33.90mV
33.40mV
Pass
Crossload2
61.70mV
28.80mV
22.40mV
20.70mV
Pass
The results above are not used in the certification process