Cables and Connectors(Non-accredited measurements)
Captive Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (530mm)
1
1
18-20AWG
No
4+4 pin EPS12V (580mm)
1
1
18AWG
No
6+2 pin PCIe (530mm)
1
1
18AWG
No
SATA (430mm+150mm) / 4-pin Molex (+150mm)
2
4 / 2
18AWG
No
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
18
15
33
2.5
0.3
Watts
100
396
12.5
3.6
Total Max. Power (W)
500
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
ErP Lot 6 2010: ✓
ErP Lot 6 2013: ✓
ErP Lot 3 2014 & CEC: ✗
(EU) No 617/2013 Compliance
✗
Performance Summary 230V
Accredited
Average Efficiency (>1450 load combinations)
81.920%
Average Noise Output (>1450 Load Combinations)
26.56dBA
Average PF (>1450 Load Combinations)
0.934
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1537W
Non-Accredited
12V Ripple (Full Load)
49.44mV
5V Ripple (Full Load)
39.18mV
3.3V Ripple (Full Load)
83.62mV
5VSB Ripple (Full Load)
32.14mV
12V Load Regulation
1.70%
5V Load Regulation
4.99%
3.3V Load Regulation
3.90%
5VSB Load Regulation
5.33%
Inrush Current
89.260A
Hold-Up Time & PWR_OK Signal
8.70ms
AC Loss to PWR_OK Hold Up Time
15.80ms
PWR_OK Inactive to DC Loss Delay
-7.10ms
PSU Timings: T1 (20% / 100%)
60.0ms
56.0ms
PSU Timings: T3 (20% / 100%)
270.0ms
286.0ms
OPP (25.80°C / 0.00°C)
104.36%
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
8.7
AC Loss to PWR_OK Hold Up Time (ms)
15.8
PWR_OK Inactive to DC Loss Delay (ms)
-7.1
待機電源消耗
Tables 230V
Graphs 230V
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
48.632%
0.014
5.147V
0.475
230.30V
2
0.090A
0.463
58.166%
0.024
5.144V
0.796
230.31V
3
0.550A
2.817
71.443%
0.110
5.122V
3.943
230.30V
4
1.000A
5.095
73.638%
0.177
5.095V
6.919
230.31V
5
1.500A
7.607
74.258%
0.233
5.072V
10.244
230.31V
6
2.499A
12.554
74.447%
0.305
5.023V
16.863
230.31V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.471A
1.977A
1.979A
0.984A
39.986
75.801%
939
21.7
30.12°C
0.579
12.503V
5.059V
3.333V
5.078V
52.751
33.11°C
230.25V
2
3.936A
2.979A
2.981A
1.187A
80.009
82.109%
939
21.7
30.77°C
0.831
12.478V
5.037V
3.319V
5.052V
97.442
34.19°C
230.25V
3
6.750A
3.476A
3.491A
1.392A
119.946
84.181%
940
21.7
31.26°C
0.889
12.431V
5.033V
3.307V
5.027V
142.485
35.93°C
230.26V
4
9.591A
3.977A
4.007A
1.599A
159.979
84.662%
951
21.3
31.58°C
0.929
12.385V
5.028V
3.294V
5.003V
188.961
36.71°C
230.26V
5
12.087A
5.000A
5.032A
1.809A
200.003
84.350%
964
21.2
32.22°C
0.948
12.368V
5.001V
3.280V
4.976V
237.110
37.84°C
230.28V
6
14.580A
6.038A
6.064A
2.000A
239.848
83.750%
1298
28.3
32.70°C
0.958
12.356V
4.969V
3.265V
4.948V
286.387
38.83°C
230.28V
7
17.081A
7.097A
7.115A
2.236A
280.017
83.024%
1441
31.0
33.39°C
0.964
12.347V
4.933V
3.248V
4.919V
337.272
40.25°C
230.29V
8
19.580A
8.002A
8.163A
2.452A
319.202
82.310%
1512
32.4
33.93°C
0.967
12.339V
4.902V
3.232V
4.892V
387.805
41.57°C
230.29V
9
22.525A
8.712A
8.696A
2.461A
359.918
81.654%
1571
33.3
34.62°C
0.970
12.317V
4.878V
3.218V
4.875V
440.786
42.81°C
230.30V
10
25.449A
9.264A
9.265A
2.577A
399.985
80.812%
1734
36.8
35.09°C
0.973
12.291V
4.858V
3.204V
4.851V
494.957
44.28°C
230.31V
11
28.814A
9.266A
9.302A
2.586A
439.881
79.873%
1811
37.3
35.78°C
0.975
12.240V
4.856V
3.193V
4.834V
550.725
45.54°C
230.31V
CL1
0.000A
00.000A
00.000A
00.000A
0000.00
00.000%
0
0
00.0°C
0.000
00.000V
00.000V
00.000V
00.000V
0000.00
00.0°C
000.0V
CL2
33.004A
1.001A
1.001A
1.000A
405.324
82.097%
1494
32.0
32.14°C
0.973
11.875V
5.188V
3.243V
4.962V
493.714
37.53°C
230.30V
The results above are not used in the certification process
Light Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.191A
0.488A
0.493A
0.195A
19.974
69.705%
906
19.4
0.404
12.447V
5.122V
3.347V
5.131V
28.655
230.21V
2
2.384A
0.978A
0.989A
0.391A
39.964
77.916%
913
19.3
0.570
12.445V
5.105V
3.340V
5.114V
51.291
230.22V
3
3.582A
1.474A
1.483A
0.589A
59.996
81.577%
921
18.7
0.708
12.437V
5.091V
3.332V
5.096V
73.545
230.23V
4
4.776A
1.969A
1.984A
0.788A
79.948
83.326%
926
18.9
0.825
12.427V
5.079V
3.324V
5.077V
95.946
230.24V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
11.80mV
10.60mV
28.50mV
7.50mV
Pass
20% Load
16.50mV
16.50mV
38.10mV
13.00mV
Pass
30% Load
14.20mV
14.60mV
34.60mV
12.20mV
Pass
40% Load
16.00mV
16.50mV
43.20mV
14.30mV
Pass
50% Load
17.00mV
18.00mV
43.40mV
15.40mV
Pass
60% Load
26.40mV
24.40mV
46.60mV
24.30mV
Pass
70% Load
31.10mV
27.40mV
62.00mV
27.60mV
Fail
80% Load
38.40mV
30.70mV
74.20mV
28.70mV
Fail
90% Load
41.60mV
35.30mV
76.40mV
31.10mV
Fail
100% Load
49.40mV
39.20mV
83.60mV
32.10mV
Fail
110% Load
57.40mV
42.50mV
83.00mV
33.40mV
Fail
Crossload1
0.00mV
0.00mV
0.00mV
0.00mV
Pass
Crossload2
37.50mV
30.00mV
37.10mV
12.30mV
Pass
The results above are not used in the certification process