Cables and Connectors(Non-accredited measurements)
Captive Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (300mm)
1
1
20-22AWG
No
4+4 pin EPS12V (400mm)
1
1
18-20AWG
No
6+2 pin PCIe (400mm)
1
2
18-20AWG
No
SATA (300mm+150mm)
1
2
20AWG
No
4-pin Molex (300mm+150mm)
1
2
20AWG
No
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
16
15
27
3
0.3
Watts
105
324
15
3.6
Total Max. Power (W)
350
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
ErP Lot 6 2010: ✓
ErP Lot 6 2013: ✓
ErP Lot 3 2014 & CEC: Partially
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
Performance Summary 230V
Accredited
Average Efficiency (>1450 load combinations)
84.752%
Average Noise Output (>1450 Load Combinations)
29.52dBA
Average PF (>1450 Load Combinations)
0.971
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.2249W
Non-Accredited
12V Ripple (Full Load)
38.78mV
5V Ripple (Full Load)
19.63mV
3.3V Ripple (Full Load)
23.50mV
5VSB Ripple (Full Load)
15.64mV
12V Load Regulation
0.90%
5V Load Regulation
2.77%
3.3V Load Regulation
1.79%
5VSB Load Regulation
2.68%
Inrush Current
74.830A
Hold-Up Time & PWR_OK Signal
8.10ms
AC Loss to PWR_OK Hold Up Time
46.20ms
PWR_OK Inactive to DC Loss Delay
-38.10ms
PSU Timings: T1 (20% / 100%)
58.0ms
54.5ms
PSU Timings: T3 (20% / 100%)
104.5ms
101.0ms
OPP (22.95°C / 0.00°C)
134.22%
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
8.1
AC Loss to PWR_OK Hold Up Time (ms)
46.2
PWR_OK Inactive to DC Loss Delay (ms)
-38.1
待機電源消耗
Tables 230V
Graphs 230V
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
51.919%
0.027
5.123V
0.443
230.26V
2
0.090A
0.461
60.898%
0.046
5.119V
0.757
230.26V
3
0.550A
2.806
73.745%
0.195
5.104V
3.805
230.26V
4
1.000A
5.091
75.804%
0.277
5.092V
6.716
230.26V
5
1.500A
7.616
76.550%
0.328
5.078V
9.949
230.26V
6
2.999A
15.098
75.336%
0.396
5.034V
20.041
230.26V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.094A
1.995A
1.973A
0.983A
35.028
77.944%
730
8.1
30.94°C
0.827
12.271V
5.014V
3.345V
5.087V
44.940
34.19°C
230.28V
2
3.188A
3.000A
2.965A
1.182A
70.010
83.670%
751
6.6
31.11°C
0.923
12.268V
5.001V
3.338V
5.076V
83.674
34.82°C
230.29V
3
5.633A
3.501A
3.465A
1.382A
104.998
85.634%
1025
8.6
31.56°C
0.956
12.240V
5.000V
3.332V
5.065V
122.613
35.77°C
230.29V
4
8.085A
4.001A
3.968A
1.583A
139.986
86.373%
1271
16.4
32.28°C
0.968
12.219V
4.997V
3.327V
5.054V
162.071
37.14°C
230.29V
5
10.184A
5.019A
4.971A
1.785A
174.972
86.353%
1543
23.2
33.31°C
0.976
12.222V
4.981V
3.320V
5.042V
202.625
38.67°C
230.30V
6
12.282A
6.046A
5.976A
1.988A
209.956
86.040%
1789
27.9
33.51°C
0.980
12.225V
4.964V
3.313V
5.029V
244.021
39.65°C
230.30V
7
14.385A
7.077A
6.985A
2.192A
245.021
85.585%
1942
30.7
33.69°C
0.980
12.229V
4.947V
3.307V
5.017V
286.289
40.71°C
230.30V
8
16.487A
8.003A
7.995A
2.397A
279.455
84.999%
2146
33.4
33.95°C
0.980
12.228V
4.932V
3.300V
5.005V
328.775
41.92°C
230.30V
9
19.042A
8.625A
8.496A
2.400A
314.923
84.458%
2282
35.0
34.62°C
0.980
12.206V
4.928V
3.295V
4.999V
372.876
43.39°C
230.31V
10
21.369A
9.139A
9.030A
3.016A
349.976
83.593%
2520
37.8
35.14°C
0.980
12.181V
4.923V
3.288V
4.973V
418.667
44.75°C
230.32V
11
24.360A
9.117A
9.042A
3.019A
384.986
82.918%
2658
39.6
35.51°C
0.981
12.122V
4.936V
3.284V
4.968V
464.297
46.23°C
230.32V
CL1
8.000A
12.999A
12.997A
0.000A
205.634
82.821%
2281
35.0
33.77°C
0.980
12.581V
4.778V
3.299V
5.078V
248.288
39.29°C
230.32V
CL2
26.977A
0.999A
1.000A
1.000A
329.322
84.651%
1977
31.0
35.32°C
0.981
11.706V
5.171V
3.312V
5.051V
389.037
45.29°C
230.32V
The results above are not used in the certification process
Light Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.217A
0.493A
0.492A
0.196A
19.978
74.034%
706
8.2
0.713
12.184V
5.066V
3.355V
5.112V
26.985
230.25V
2
2.434A
0.989A
0.985A
0.392A
39.968
81.609%
710
9.0
0.841
12.189V
5.055V
3.350V
5.103V
48.975
230.26V
3
3.654A
1.486A
1.481A
0.589A
60.000
84.478%
717
9.5
0.902
12.192V
5.044V
3.345V
5.095V
71.024
230.26V
4
4.869A
1.986A
1.974A
0.786A
79.951
85.710%
742
7.1
0.932
12.191V
5.036V
3.340V
5.087V
93.281
230.27V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.70mV
11.10mV
14.10mV
10.50mV
Pass
20% Load
8.90mV
9.70mV
15.60mV
11.40mV
Pass
30% Load
8.90mV
8.70mV
15.40mV
12.40mV
Pass
40% Load
10.50mV
7.70mV
15.40mV
13.00mV
Pass
50% Load
12.70mV
8.20mV
16.70mV
13.10mV
Pass
60% Load
14.40mV
9.90mV
17.80mV
13.60mV
Pass
70% Load
25.20mV
28.10mV
21.40mV
19.90mV
Pass
80% Load
19.10mV
11.30mV
21.90mV
15.00mV
Pass
90% Load
21.50mV
11.50mV
21.00mV
14.50mV
Pass
100% Load
38.80mV
19.60mV
23.50mV
15.60mV
Pass
110% Load
44.20mV
22.80mV
23.50mV
15.70mV
Pass
Crossload1
20.90mV
18.70mV
24.00mV
24.90mV
Pass
Crossload2
33.50mV
13.10mV
10.90mV
13.60mV
Pass
The results above are not used in the certification process