CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Micronics Classic II Full Change 500W
Serial Number2105CL2F0500PA00001
Lab IDMC50001825
Certification ID251825
  • Test Result Report ID: 21PS1825A
  • Certificate Issue Date: Apr 2, 2021
230V
Scheme: ETA-EMI PSU
230V
Scheme: LAMBDA PSU
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary 230V

Hold-Up Time & PWR_OK Signal

Stromverbrauch im Ruhezustand

Tables 230V

Graphs 230V

Efficiency Graph

230V

Noise Graph

230V

Noise under high ambient temperature (indicative)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%440 RPM · 11.3 dB(A) · 34.2 °C440 RPM · 11.3 dB(A) · 34.2 °C+0.0 dB(A)
20%548 RPM · 14.9 dB(A) · 34.4 °C548 RPM · 14.9 dB(A) · 34.4 °C+0.0 dB(A)
50%1013 RPM · 31.9 dB(A) · 36.5 °C1013 RPM · 31.9 dB(A) · 36.5 °C+0.0 dB(A)
100%1735 RPM · 46.1 dB(A) · 39.3 °C1735 RPM · 46.1 dB(A) · 39.3 °C+0.0 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC) 230V

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests 230V

Light Load Tests 230V

Ripple Measurements 230V

Micronics Classic II Full Change 500W

Top side
Top side
Power specifications label
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus