Cables and Connectors(Non-accredited measurements)
Captive Cables
Description
Cable Count
Connector Count (Total)
Gauge
ATX connector 20+4 pin (600mm)
1
1
18-20AWG
4+4 pin EPS12V (650mm)
1
1
18AWG
6+2 pin PCIe (580mm)
2
2
18AWG
SATA (400mm+120mm+120mm)
1
3
18AWG
SATA (400mm+120mm)
1
2
18AWG
4 pin Molex (400mm+120mm+120mm+120mm)
1
4
18AWG
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
25
20
45.8
3
0.8
Watts
120
549.6
15
9.6
Total Max. Power (W)
550
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
85.720%
Average Noise Output (>1450 Load Combinations)
23.69dBA
Average PF (>1450 Load Combinations)
0.996
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.0554W
Non-Accredited
12V Ripple (Full Load)
32.34mV
5V Ripple (Full Load)
11.40mV
3.3V Ripple (Full Load)
11.53mV
5VSB Ripple (Full Load)
19.87mV
12V Load Regulation
0.54%
5V Load Regulation
0.36%
3.3V Load Regulation
0.45%
5VSB Load Regulation
1.98%
Inrush Current
34.858A
Accredited
Average Efficiency (>1450 load combinations)
88.024%
Average Noise Output (>1450 Load Combinations)
25.42dBA
Average PF (>1450 Load Combinations)
0.975
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.0703W
Non-Accredited
12V Ripple (Full Load)
33.03mV
5V Ripple (Full Load)
18.05mV
3.3V Ripple (Full Load)
13.11mV
5VSB Ripple (Full Load)
17.23mV
12V Load Regulation
0.45%
5V Load Regulation
0.38%
3.3V Load Regulation
0.66%
5VSB Load Regulation
1.83%
Inrush Current
40.550A
Hold-Up Time & PWR_OK Signal
11.93ms
AC Loss to PWR_OK Hold Up Time
9.90ms
PWR_OK Inactive to DC Loss Delay
2.03ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
11.93
AC Loss to PWR_OK Hold Up Time (ms)
9.90
PWR_OK Inactive to DC Loss Delay (ms)
2.03
Stromverbrauch im Ruhezustand
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.215
66.358%
0.043
5.107V
0.324
115.08V
2
0.088A
0.448
73.322%
0.079
5.106V
0.611
115.08V
3
0.542A
2.766
78.759%
0.296
5.099V
3.512
115.06V
4
1.002A
5.104
78.924%
0.370
5.092V
6.467
115.06V
5
1.502A
7.636
78.787%
0.408
5.084V
9.692
115.07V
6
3.002A
15.189
77.365%
0.458
5.060V
19.633
115.07V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.102A
0.519
69.385%
0.030
5.106V
0.748
230.22V
2
0.252A
1.287
74.221%
0.068
5.104V
1.734
230.22V
3
0.543A
2.766
77.219%
0.130
5.098V
3.582
230.23V
4
1.003A
5.104
78.007%
0.206
5.091V
6.543
230.23V
5
1.502A
7.635
78.163%
0.260
5.083V
9.768
230.23V
6
3.002A
15.185
78.237%
0.341
5.059V
19.409
230.23V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.745A
1.984A
1.989A
0.981A
54.755
78.702%
818
13.8
38.07°C
0.979
12.098V
5.026V
3.313V
5.081V
69.573
44.81°C
115.11V
2
6.528A
2.981A
2.988A
1.181A
109.782
84.892%
818
13.8
38.38°C
0.991
12.090V
5.024V
3.310V
5.073V
129.319
45.86°C
115.11V
3
10.659A
3.488A
3.502A
1.381A
164.906
86.912%
818
13.8
38.85°C
0.997
12.084V
5.023V
3.309V
5.065V
189.740
47.43°C
115.11V
4
14.791A
3.983A
3.989A
1.581A
219.820
87.621%
818
13.8
39.44°C
0.998
12.077V
5.021V
3.308V
5.057V
250.876
49.36°C
115.12V
5
18.581A
4.978A
4.990A
1.781A
274.746
87.634%
818
13.8
40.12°C
0.998
12.070V
5.019V
3.306V
5.049V
313.515
50.52°C
115.12V
6
22.377A
5.979A
5.989A
1.981A
329.709
87.218%
983
21.0
40.94°C
0.998
12.063V
5.018V
3.304V
5.040V
378.028
51.49°C
115.12V
7
26.182A
6.980A
6.991A
2.186A
384.725
86.668%
1180
26.2
41.77°C
0.999
12.055V
5.016V
3.303V
5.031V
443.909
52.78°C
115.12V
8
29.983A
7.980A
7.995A
2.387A
439.578
85.971%
1381
30.8
43.03°C
0.999
12.047V
5.013V
3.300V
5.021V
511.307
54.65°C
115.12V
9
34.222A
8.481A
8.515A
2.391A
494.664
85.226%
1578
34.4
44.23°C
0.999
12.041V
5.012V
3.300V
5.015V
580.413
56.03°C
115.12V
10
38.210A
8.987A
9.002A
2.999A
549.559
84.280%
1630
35.1
45.51°C
0.999
12.035V
5.010V
3.298V
4.998V
652.061
58.26°C
115.12V
11
42.798A
8.990A
9.008A
3.001A
604.480
83.354%
1630
35.1
46.70°C
0.999
12.028V
5.009V
3.296V
4.993V
725.193
60.18°C
115.14V
CL1
0.097A
14.025A
14.004A
0.004A
117.895
81.102%
818
13.8
43.19°C
0.994
12.079V
5.019V
3.307V
5.072V
145.366
55.91°C
115.13V
CL2
45.787A
1.004A
1.003A
1.002A
564.588
84.877%
1630
35.1
45.25°C
0.999
12.038V
5.017V
3.303V
5.044V
665.186
58.69°C
115.13V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.747A
1.985A
1.989A
0.981A
54.781
80.669%
818
13.8
38.04°C
0.861
12.100V
5.026V
3.310V
5.080V
67.908
44.53°C
230.11V
2
6.530A
2.977A
2.990A
1.181A
109.813
87.010%
818
13.8
38.41°C
0.948
12.094V
5.024V
3.308V
5.073V
126.208
45.46°C
230.11V
3
10.659A
3.486A
3.503A
1.381A
164.939
88.881%
818
13.8
38.73°C
0.973
12.089V
5.022V
3.306V
5.065V
185.572
46.58°C
230.12V
4
14.787A
3.981A
3.992A
1.580A
219.837
89.619%
818
13.8
38.88°C
0.982
12.083V
5.020V
3.304V
5.057V
245.303
48.26°C
230.13V
5
18.573A
4.977A
4.996A
1.781A
274.765
89.770%
818
13.8
39.33°C
0.983
12.077V
5.019V
3.300V
5.049V
306.076
50.34°C
230.13V
6
22.366A
5.977A
6.001A
1.981A
329.748
89.507%
1080
22.1
40.31°C
0.990
12.071V
5.017V
3.299V
5.040V
368.406
50.87°C
230.15V
7
26.162A
6.982A
7.006A
2.185A
384.745
89.156%
1286
28.5
41.56°C
0.992
12.065V
5.015V
3.296V
5.031V
431.539
51.81°C
230.15V
8
29.964A
7.981A
8.012A
2.386A
439.682
88.675%
1480
33.3
42.37°C
0.994
12.058V
5.012V
3.294V
5.023V
495.834
52.63°C
230.16V
9
34.197A
8.481A
8.531A
2.391A
494.728
88.170%
1630
35.1
43.35°C
0.994
12.052V
5.011V
3.293V
5.017V
561.108
54.14°C
230.18V
10
38.176A
8.989A
9.025A
2.996A
549.581
87.447%
1630
35.1
45.03°C
0.995
12.046V
5.009V
3.291V
5.002V
628.473
56.89°C
230.19V
11
42.759A
8.991A
9.029A
3.000A
604.566
86.897%
1630
35.1
46.01°C
0.995
12.041V
5.007V
3.289V
4.997V
695.726
58.77°C
230.21V
CL1
0.101A
14.024A
14.004A
0.005A
117.888
82.942%
1015
21.1
43.84°C
0.959
12.077V
5.019V
3.303V
5.079V
142.133
54.42°C
230.20V
CL2
45.791A
1.002A
1.004A
1.002A
565.352
88.046%
1630
35.1
44.70°C
0.995
12.054V
5.013V
3.297V
5.044V
642.109
56.65°C
230.22V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.207A
0.490A
0.481A
0.196A
19.667
64.635%
818
13.8
0.920
12.104V
5.030V
3.314V
5.099V
30.428
115.11V
2
2.440A
0.990A
0.997A
0.391A
39.797
76.181%
818
13.8
0.965
12.100V
5.028V
3.313V
5.093V
52.240
115.10V
3
3.672A
1.485A
1.509A
0.586A
59.870
80.302%
818
13.8
0.979
12.098V
5.027V
3.313V
5.089V
74.556
115.10V
4
4.895A
1.986A
1.989A
0.786A
79.768
82.837%
818
13.8
0.986
12.095V
5.026V
3.312V
5.083V
96.295
115.11V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.211A
0.490A
0.480A
0.196A
19.713
65.461%
818
13.8
0.599
12.105V
5.030V
3.313V
5.097V
30.114
230.08V
2
2.442A
0.986A
0.996A
0.391A
39.800
77.706%
818
13.8
0.781
12.102V
5.028V
3.312V
5.092V
51.219
230.09V
3
3.675A
1.484A
1.510A
0.586A
59.907
82.283%
818
13.8
0.870
12.100V
5.027V
3.310V
5.087V
72.806
230.09V
4
4.899A
1.984A
1.991A
0.786A
79.824
84.836%
818
13.8
0.914
12.098V
5.026V
3.310V
5.081V
94.092
230.10V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
14.2 mV
7.1 mV
4.8 mV
9.4 mV
Pass
20% Load
17.8 mV
7.5 mV
5.5 mV
10.0 mV
Pass
30% Load
17.8 mV
7.7 mV
6.2 mV
10.7 mV
Pass
40% Load
19.6 mV
7.9 mV
6.7 mV
11.5 mV
Pass
50% Load
21.3 mV
8.3 mV
7.3 mV
12.0 mV
Pass
60% Load
27.3 mV
8.7 mV
8.9 mV
12.6 mV
Pass
70% Load
28.3 mV
10.0 mV
12.0 mV
14.7 mV
Pass
80% Load
29.7 mV
9.7 mV
10.6 mV
14.9 mV
Pass
90% Load
31.2 mV
10.1 mV
10.5 mV
16.6 mV
Pass
100% Load
32.3 mV
11.4 mV
11.5 mV
19.9 mV
Pass
110% Load
35.8 mV
12.2 mV
12.2 mV
22.8 mV
Pass
Crossload 1
23.5 mV
7.1 mV
6.7 mV
9.8 mV
Pass
Crossload 2
33.7 mV
10.6 mV
11.8 mV
18.7 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
15.4 mV
14.6 mV
7.8 mV
13.3 mV
Pass
20% Load
19.2 mV
14.7 mV
8.1 mV
13.3 mV
Pass
30% Load
22.2 mV
15.4 mV
8.4 mV
14.2 mV
Pass
40% Load
22.0 mV
13.8 mV
8.7 mV
14.8 mV
Pass
50% Load
23.9 mV
14.6 mV
9.8 mV
14.6 mV
Pass
60% Load
30.0 mV
16.4 mV
10.7 mV
14.3 mV
Pass
70% Load
31.7 mV
18.3 mV
15.3 mV
15.8 mV
Pass
80% Load
31.5 mV
16.9 mV
12.5 mV
14.5 mV
Pass
90% Load
34.9 mV
16.0 mV
11.8 mV
14.7 mV
Pass
100% Load
33.0 mV
18.1 mV
13.1 mV
17.2 mV
Pass
110% Load
38.4 mV
18.6 mV
13.6 mV
18.0 mV
Pass
Crossload 1
25.5 mV
16.7 mV
8.9 mV
14.6 mV
Pass
Crossload 2
37.2 mV
17.3 mV
12.5 mV
16.4 mV
Pass
The results above are not used in the certification process