Cables and Connectors(Non-accredited measurements)
Captive Cables
Description
Cable Count
Connector Count (Total)
Gauge
ATX connector 20+4 pin (560mm)
1
1
18-22AWG
4+4 pin EPS12V (620mm)
1
1
18AWG
6+2 pin PCIe (580mm+120mm)
1
2
20AWG
SATA (470mm+120mm+120mm)
2
6
20AWG
4 pin Molex (480mm+120mm+120mm) / FDD (+120mm)
1
3 / 1
20-22AWG
Protection Features(Manufacturer)
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
24
20
40
3
0.3
Watts
120
480
15
3.6
Total Max. Power (W)
500
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary 115V
Accredited
Average Efficiency (>1450 load combinations)
82.363%
Average Noise Output (>1450 Load Combinations)
35.75dBA
Average PF (>1450 Load Combinations)
0.963
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.0569W
Non-Accredited
12V Ripple (Full Load)
65.18mV
5V Ripple (Full Load)
26.09mV
3.3V Ripple (Full Load)
30.28mV
5VSB Ripple (Full Load)
24.27mV
12V Load Regulation
2.00%
5V Load Regulation
1.24%
3.3V Load Regulation
2.66%
5VSB Load Regulation
3.39%
Inrush Current
49.506A
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
15.62
AC Loss to PWR_OK Hold Up Time (ms)
10.10
PWR_OK Inactive to DC Loss Delay (ms)
5.52
待機電源消耗
Tables 115V
Graphs 115V
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.209
66.561%
0.058
5.025V
0.314
115.16V
2
0.087A
0.438
73.862%
0.104
5.025V
0.593
115.16V
3
0.542A
2.719
79.549%
0.311
5.016V
3.418
115.13V
4
1.002A
5.018
79.399%
0.365
5.009V
6.320
115.14V
5
1.502A
7.504
79.500%
0.392
4.997V
9.439
115.15V
6
3.001A
14.911
75.510%
0.438
4.969V
19.747
115.15V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.311A
1.980A
1.955A
1.000A
49.767
75.032%
957
20.3
38.29°C
0.890
12.195V
5.051V
3.375V
4.986V
66.328
43.31°C
115.18V
2
5.660A
2.972A
2.938A
1.206A
99.767
81.658%
1128
25.3
38.42°C
0.935
12.172V
5.042V
3.366V
4.975V
122.176
43.65°C
115.18V
3
9.373A
3.467A
3.450A
1.410A
149.889
83.727%
1300
29.2
38.82°C
0.952
12.143V
5.045V
3.358V
4.962V
179.021
44.35°C
115.19V
4
13.092A
3.962A
3.940A
1.616A
199.770
84.365%
1486
33.1
39.58°C
0.961
12.113V
5.047V
3.349V
4.948V
236.792
45.69°C
115.19V
5
16.482A
4.969A
4.938A
1.823A
249.792
84.410%
1660
36.2
40.23°C
0.967
12.091V
5.037V
3.339V
4.932V
295.926
47.14°C
115.19V
6
19.884A
5.965A
5.941A
2.035A
299.773
84.155%
1865
39.2
41.19°C
0.972
12.070V
5.029V
3.330V
4.910V
356.216
48.94°C
115.19V
7
23.299A
6.975A
6.958A
2.245A
349.763
83.685%
2015
41.4
42.64°C
0.977
12.046V
5.021V
3.318V
4.898V
417.954
51.29°C
115.20V
8
26.729A
7.978A
7.974A
2.455A
399.694
83.147%
2023
41.5
44.12°C
0.980
12.021V
5.015V
3.309V
4.883V
480.710
53.83°C
115.20V
9
30.635A
8.472A
8.515A
2.460A
449.755
82.548%
2023
41.5
45.49°C
0.982
11.985V
5.019V
3.299V
4.871V
544.843
57.17°C
115.21V
10
34.299A
8.968A
9.028A
3.094A
499.618
81.802%
2023
41.5
46.48°C
0.983
11.951V
5.020V
3.290V
4.845V
610.768
59.11°C
115.23V
11
38.606A
8.948A
9.048A
3.097A
549.574
81.107%
2023
41.5
46.64°C
0.983
11.912V
5.031V
3.282V
4.839V
677.593
59.94°C
115.25V
CL1
0.101A
14.026A
14.003A
0.004A
113.347
75.270%
2045
41.8
44.29°C
0.948
12.528V
4.659V
3.336V
4.949V
150.587
53.05°C
115.19V
CL2
39.968A
1.003A
1.002A
1.002A
484.585
82.241%
2015
41.4
45.50°C
0.983
11.787V
5.213V
3.316V
4.922V
589.228
56.76°C
115.22V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.200A
0.492A
0.472A
0.196A
19.695
62.118%
787
15.6
0.837
12.176V
5.089V
3.384V
5.015V
31.706
115.18V
2
2.423A
0.980A
0.975A
0.396A
39.754
73.542%
822
16.2
0.880
12.175V
5.078V
3.380V
5.005V
54.056
115.18V
3
3.651A
1.470A
1.479A
0.601A
59.883
78.235%
957
20.3
0.907
12.171V
5.069V
3.376V
4.995V
76.542
115.18V
4
4.865A
1.976A
1.953A
0.801A
79.777
80.606%
1040
22.8
0.920
12.167V
5.062V
3.372V
4.989V
98.972
115.18V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
29.9 mV
18.0 mV
27.5 mV
18.0 mV
Pass
20% Load
31.4 mV
20.6 mV
32.4 mV
19.2 mV
Pass
30% Load
34.8 mV
18.9 mV
35.0 mV
18.0 mV
Pass
40% Load
36.4 mV
18.9 mV
26.8 mV
15.5 mV
Pass
50% Load
43.1 mV
18.8 mV
26.9 mV
18.5 mV
Pass
60% Load
46.0 mV
20.1 mV
27.1 mV
18.8 mV
Pass
70% Load
51.9 mV
21.3 mV
28.9 mV
18.9 mV
Pass
80% Load
57.8 mV
23.2 mV
30.4 mV
22.4 mV
Pass
90% Load
61.6 mV
24.3 mV
27.6 mV
24.1 mV
Pass
100% Load
65.2 mV
26.1 mV
30.3 mV
24.3 mV
Pass
110% Load
71.3 mV
26.5 mV
34.3 mV
27.2 mV
Pass
Crossload 1
42.7 mV
59.9 mV
27.0 mV
22.6 mV
Fail
Crossload 2
72.0 mV
57.4 mV
30.8 mV
29.6 mV
Fail
The results above are not used in the certification process