Cables and Connectors(Non-accredited measurements)
Captive Cables
Description
Cable Count
Connector Count (Total)
Gauge
ATX connector 20+4 pin (610mm)
1
1
18-22AWG
4+4 pin EPS12V (620mm)
1
1
18AWG
Modular Cables
6+2 pin PCIe (600mm+100mm)
1
2
18AWG
SATA (460mm+120mm+120mm)
2
6
18AWG
4 pin Molex (470mm+120mm+120mm) / FDD (+120mm)
1
3 / 1
18AWG
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
20
20
50
2.5
0.3
Watts
120
600
12.5
3.6
Total Max. Power (W)
600
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
ErP Lot 3/6 2010: ✓
ErP Lot 3/6 2013: ✓
ErP Lot 3/6 2014, CEC: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
85.095%
Average Noise Output (>1450 Load Combinations)
37.30dBA
Average PF (>1450 Load Combinations)
0.992
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.0812W
Non-Accredited
12V Ripple (Full Load)
26.39mV
5V Ripple (Full Load)
12.75mV
3.3V Ripple (Full Load)
13.29mV
5VSB Ripple (Full Load)
21.95mV
12V Load Regulation
0.31%
5V Load Regulation
0.10%
3.3V Load Regulation
0.86%
5VSB Load Regulation
3.75%
Inrush Current
90.255A
Accredited
Average Efficiency (>1450 load combinations)
87.464%
Average Noise Output (>1450 Load Combinations)
37.08dBA
Average PF (>1450 Load Combinations)
0.964
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1652W
Non-Accredited
12V Ripple (Full Load)
21.57mV
5V Ripple (Full Load)
12.22mV
3.3V Ripple (Full Load)
13.24mV
5VSB Ripple (Full Load)
23.61mV
12V Load Regulation
0.24%
5V Load Regulation
0.10%
3.3V Load Regulation
0.83%
5VSB Load Regulation
3.64%
Inrush Current
59.579A
Hold-Up Time & PWR_OK Signal
13.31ms
AC Loss to PWR_OK Hold Up Time
12.66ms
PWR_OK Inactive to DC Loss Delay
0.65ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
13.31
AC Loss to PWR_OK Hold Up Time (ms)
12.66
PWR_OK Inactive to DC Loss Delay (ms)
0.65
Stromverbrauch im Ruhezustand
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.214
69.032%
0.038
5.071V
0.310
115.05V
2
0.088A
0.446
74.457%
0.072
5.070V
0.599
115.05V
3
0.543A
2.747
77.643%
0.278
5.061V
3.538
115.04V
4
1.003A
5.066
78.312%
0.345
5.052V
6.469
115.04V
5
1.502A
7.575
77.812%
0.378
5.043V
9.735
115.04V
6
2.502A
12.566
77.163%
0.412
5.023V
16.285
115.04V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.215
60.734%
0.013
5.071V
0.354
230.20V
2
0.088A
0.445
67.424%
0.024
5.070V
0.660
230.20V
3
0.543A
2.746
74.620%
0.124
5.061V
3.680
230.18V
4
1.003A
5.066
76.641%
0.195
5.052V
6.610
230.18V
5
1.502A
7.574
76.590%
0.249
5.043V
9.889
230.19V
6
2.502A
12.566
77.678%
0.309
5.023V
16.177
230.19V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.177A
1.975A
1.961A
0.991A
59.833
80.164%
1296
32.5
38.17°C
0.973
12.034V
5.074V
3.361V
5.033V
74.638
42.05°C
115.12V
2
7.390A
2.950A
2.944A
1.196A
119.767
85.761%
1474
38.3
38.64°C
0.990
12.032V
5.073V
3.358V
5.015V
139.652
42.57°C
115.12V
3
11.957A
3.453A
3.454A
1.400A
179.925
86.979%
1614
37.5
39.43°C
0.994
12.029V
5.071V
3.355V
4.997V
206.860
43.80°C
115.13V
4
16.516A
3.944A
3.935A
1.605A
239.787
87.034%
1737
39.3
39.73°C
0.992
12.025V
5.070V
3.352V
4.982V
275.509
45.05°C
115.13V
5
20.735A
4.936A
4.925A
1.811A
299.774
86.671%
1757
39.7
40.09°C
0.992
12.022V
5.069V
3.348V
4.964V
345.874
46.95°C
115.13V
6
24.960A
5.918A
5.918A
2.020A
359.725
86.078%
1770
39.9
40.99°C
0.993
12.017V
5.069V
3.345V
4.944V
417.904
49.00°C
115.13V
7
29.184A
6.909A
6.909A
2.230A
419.687
85.297%
1770
39.9
42.30°C
0.994
12.013V
5.069V
3.343V
4.924V
492.033
52.04°C
115.13V
8
33.411A
7.895A
7.904A
2.445A
479.596
84.355%
1770
39.9
43.38°C
0.995
12.008V
5.069V
3.339V
4.902V
568.545
55.58°C
115.14V
9
38.079A
8.388A
8.422A
2.454A
539.686
83.252%
1776
39.9
44.97°C
0.996
12.003V
5.071V
3.336V
4.887V
648.259
59.71°C
115.14V
10
42.693A
8.879A
8.909A
2.565A
599.474
81.986%
1776
39.9
45.46°C
0.996
11.999V
5.071V
3.332V
4.870V
731.195
61.61°C
115.15V
11
47.703A
8.879A
8.916A
2.570A
659.392
80.742%
1776
39.9
46.55°C
0.996
11.995V
5.070V
3.331V
4.856V
816.667
65.37°C
115.15V
CL1
0.099A
14.027A
14.004A
0.004A
119.438
81.675%
1770
39.9
44.93°C
0.991
12.023V
5.083V
3.351V
4.990V
146.235
52.97°C
115.15V
CL2
49.950A
1.004A
1.002A
1.000A
612.815
82.236%
1776
39.9
46.61°C
0.996
12.001V
5.070V
3.337V
4.932V
745.194
62.86°C
115.16V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.167A
1.966A
1.958A
0.992A
59.675
80.828%
1420
34.5
38.18°C
0.842
12.033V
5.078V
3.363V
5.038V
73.830
44.69°C
230.67V
2
7.359A
2.949A
2.942A
1.194A
119.390
86.634%
1520
37.7
38.53°C
0.930
12.030V
5.078V
3.361V
5.023V
137.809
45.65°C
230.63V
3
11.919A
3.443A
3.419A
1.397A
179.314
88.357%
1614
37.5
38.71°C
0.958
12.027V
5.077V
3.359V
5.010V
202.943
46.95°C
230.59V
4
16.481A
3.936A
3.929A
1.601A
239.326
88.924%
1737
39.3
38.88°C
0.972
12.023V
5.078V
3.357V
4.996V
269.134
48.53°C
230.64V
5
20.712A
4.920A
4.917A
1.807A
299.433
88.925%
1770
39.9
39.39°C
0.977
12.020V
5.078V
3.354V
4.980V
336.725
51.15°C
230.60V
6
24.952A
5.903A
5.905A
2.014A
359.561
88.576%
1770
39.9
40.51°C
0.981
12.015V
5.078V
3.351V
4.965V
405.933
54.52°C
230.56V
7
29.160A
6.887A
6.893A
2.223A
419.282
88.065%
1776
39.9
41.36°C
0.984
12.010V
5.080V
3.349V
4.948V
476.106
58.51°C
230.51V
8
33.435A
7.871A
7.886A
2.434A
479.801
87.383%
1776
39.9
42.22°C
0.985
12.006V
5.081V
3.346V
4.931V
549.080
62.09°C
230.46V
9
38.050A
8.360A
8.369A
2.439A
539.110
86.694%
1776
39.9
43.37°C
0.986
12.001V
5.082V
3.344V
4.920V
621.852
66.94°C
230.51V
10
42.740A
8.851A
8.888A
2.549A
599.862
85.750%
1776
39.9
45.08°C
0.987
11.995V
5.084V
3.341V
4.905V
699.547
72.80°C
230.46V
11
47.768A
8.851A
8.892A
2.554A
659.878
84.817%
1776
39.9
46.25°C
0.987
11.989V
5.084V
3.339V
4.894V
778.001
76.61°C
230.42V
CL1
0.719A
14.001A
13.996A
0.000A
126.840
83.465%
1770
39.9
42.57°C
0.940
12.025V
5.086V
3.357V
5.009V
151.968
56.45°C
230.81V
CL2
49.992A
0.996A
0.997A
1.000A
612.953
86.135%
1776
39.9
44.15°C
0.987
11.994V
5.077V
3.343V
4.959V
711.618
69.43°C
230.45V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.213A
0.492A
0.473A
0.196A
19.676
64.781%
1015
25.3
0.932
12.037V
5.068V
3.360V
5.060V
30.373
115.11V
2
2.454A
0.980A
0.981A
0.396A
39.803
76.485%
1163
29.0
0.965
12.036V
5.071V
3.361V
5.052V
52.040
115.11V
3
3.690A
1.467A
1.486A
0.592A
59.827
80.645%
1265
31.8
0.973
12.034V
5.073V
3.361V
5.042V
74.186
115.11V
4
4.919A
1.975A
1.960A
0.791A
79.783
83.176%
1326
32.0
0.988
12.034V
5.073V
3.360V
5.035V
95.921
115.11V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.170A
0.490A
0.470A
0.197A
19.143
63.625%
1326
32.0
0.579
12.035V
5.070V
3.362V
5.063V
30.087
230.69V
2
2.436A
0.982A
0.976A
0.396A
39.580
76.173%
1296
32.5
0.751
12.034V
5.073V
3.363V
5.055V
51.961
230.68V
3
3.630A
1.472A
1.453A
0.594A
59.036
81.262%
1326
32.0
0.838
12.033V
5.076V
3.363V
5.047V
72.649
230.67V
4
4.898A
1.964A
1.959A
0.794A
79.493
83.969%
1420
34.5
0.884
12.032V
5.078V
3.362V
5.039V
94.670
230.66V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
5.7 mV
5.3 mV
6.0 mV
8.6 mV
Pass
20% Load
6.9 mV
5.7 mV
6.6 mV
9.4 mV
Pass
30% Load
8.3 mV
6.1 mV
7.0 mV
10.3 mV
Pass
40% Load
9.3 mV
6.8 mV
7.7 mV
11.5 mV
Pass
50% Load
10.1 mV
7.7 mV
8.5 mV
12.7 mV
Pass
60% Load
11.9 mV
8.6 mV
9.3 mV
14.4 mV
Pass
70% Load
14.6 mV
9.5 mV
10.2 mV
16.0 mV
Pass
80% Load
19.0 mV
10.8 mV
11.6 mV
18.0 mV
Pass
90% Load
22.5 mV
11.8 mV
12.2 mV
19.4 mV
Pass
100% Load
26.4 mV
12.8 mV
13.3 mV
22.0 mV
Pass
110% Load
29.0 mV
14.0 mV
15.0 mV
24.7 mV
Pass
Crossload 1
8.3 mV
6.6 mV
9.2 mV
19.3 mV
Pass
Crossload 2
26.2 mV
13.2 mV
13.8 mV
17.4 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
5.6 mV
6.1 mV
6.7 mV
7.8 mV
Pass
20% Load
6.6 mV
6.6 mV
8.0 mV
9.1 mV
Pass
30% Load
8.4 mV
7.7 mV
8.7 mV
10.5 mV
Pass
40% Load
8.9 mV
8.4 mV
9.6 mV
10.9 mV
Pass
50% Load
11.2 mV
8.9 mV
10.8 mV
12.0 mV
Pass
60% Load
13.3 mV
10.9 mV
12.2 mV
13.6 mV
Pass
70% Load
14.7 mV
11.8 mV
13.5 mV
14.7 mV
Pass
80% Load
18.1 mV
12.4 mV
15.8 mV
16.4 mV
Pass
90% Load
21.4 mV
13.2 mV
18.0 mV
17.8 mV
Pass
100% Load
24.4 mV
14.6 mV
19.1 mV
20.6 mV
Pass
110% Load
28.4 mV
15.9 mV
20.0 mV
22.4 mV
Pass
Crossload 1
8.2 mV
9.8 mV
13.1 mV
19.2 mV
Pass
Crossload 2
24.7 mV
13.5 mV
15.4 mV
17.0 mV
Pass