Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (600mm)
1
1
16-20AWG
No
4+4 pin EPS12V (700mm)
2
2
18AWG
No
6+2 pin PCIe (550mm+150mm)
4
8
18-20AWG
No
SATA (550mm+130mm+130mm+130mm)
2
8
18AWG
No
SATA (550mm+130mm)
2
4
18AWG
No
4-pin Molex (550mm+150mm+150mm+150mm)
1
4
18AWG
No
AC Power Cord (1370mm) - C13 coupler
1
1
18AWG
-
Protection Features(Manufacturer)
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
20
20
83.3
2.5
0.5
Watts
100
999.6
12.5
6
Total Max. Power (W)
1000
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
89.703%
Average Noise Output (>1450 Load Combinations)
35.63dBA
Average PF (>1450 Load Combinations)
0.987
Efficiency With 10W (≤500W) or 2% (>500W) Load
69.448%
Standby Power Consumption
0.0655W
Non-Accredited
12V Ripple (Full Load)
12.06mV
5V Ripple (Full Load)
14.35mV
3.3V Ripple (Full Load)
18.07mV
5VSB Ripple (Full Load)
14.22mV
12V Load Regulation
0.09%
5V Load Regulation
0.28%
3.3V Load Regulation
0.67%
5VSB Load Regulation
2.59%
Inrush Current
32.810A
Accredited
Average Efficiency (>1450 load combinations)
91.765%
Average Noise Output (>1450 Load Combinations)
36.00dBA
Average PF (>1450 Load Combinations)
0.945
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1047W
Non-Accredited
12V Ripple (Full Load)
11.65mV
5V Ripple (Full Load)
14.97mV
3.3V Ripple (Full Load)
19.90mV
5VSB Ripple (Full Load)
11.01mV
12V Load Regulation
0.09%
5V Load Regulation
0.28%
3.3V Load Regulation
0.70%
5VSB Load Regulation
2.59%
Inrush Current
66.470A
Hold-Up Time & Power Ok Signal
22.40ms
AC Loss to PWR_OK Hold Up Time
16.70ms
PWR_OK Inactive to DC Loss Delay
5.70ms
PSU Timings: T1 (20% / 100%)
115.0ms
115.0ms
PSU Timings: T3 (20% / 100%)
240.0ms
240.0ms
OPP (25.49°C / 43.38°C)
103.30%
103.30%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
22.4
AC Loss to PWR_OK Hold Up Time (ms)
16.7
PWR_OK Inactive to DC Loss Delay (ms)
5.7
Stromverbrauch im Ruhezustand
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.229W
65.475%
0.029
5.082V
0.35W
115.18V
2
0.09A
0.457W
71.048%
0.054
5.081V
0.643W
115.18V
3
0.55A
2.789W
77.55%
0.24
5.069V
3.596W
115.18V
4
1A
5.06W
78.608%
0.335
5.059V
6.437W
115.18V
5
1.5A
7.571W
78.473%
0.396
5.046V
9.648W
115.17V
6
2.501A
12.549W
77.992%
0.456
5.018V
16.09W
115.17V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.229W
55.658%
0.01
5.082V
0.412W
230.38V
2
0.09A
0.457W
64.567%
0.018
5.08V
0.708W
230.38V
3
0.55A
2.789W
74.823%
0.091
5.07V
3.727W
230.38V
4
1A
5.061W
76.597%
0.152
5.059V
6.607W
230.38V
5
1.5A
7.572W
77.624%
0.206
5.047V
9.755W
230.38V
6
2.501A
12.555W
78.279%
0.285
5.021V
16.039W
230.38V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.448A
1.985A
1.989A
0.99A
100.014
87.439%
615
12.4
40.3°C
0.969
12.161V
5.039V
3.318V
5.051V
114.381
44.4°C
115.19V
20%
13.908A
2.978A
2.986A
1.191A
199.971
90.254%
704
18.4
41.23°C
0.978
12.157V
5.038V
3.316V
5.039V
221.564
45.63°C
115.19V
30%
21.717A
3.475A
3.485A
1.393A
300.025
91.379%
816
22.4
41.5°C
0.989
12.155V
5.037V
3.315V
5.027V
328.329
46.25°C
115.19V
40%
29.500A
3.973A
3.984A
1.595A
399.783
91.569%
1002
28
41.86°C
0.993
12.155V
5.035V
3.313V
5.016V
436.591
46.89°C
115.19V
50%
36.936A
4.967A
4.984A
1.799A
499.492
91.248%
1214
33.8
42.96°C
0.994
12.156V
5.034V
3.311V
5.004V
547.4
48.75°C
115.19V
60%
44.437A
5.963A
5.986A
2.001A
600.042
90.75%
1389
37.3
43.21°C
0.996
12.158V
5.033V
3.308V
4.991V
661.203
49.16°C
115.19V
70%
51.869A
6.958A
6.989A
2.21A
699.796
90.075%
1569
40.3
43.94°C
0.996
12.159V
5.032V
3.306V
4.978V
776.905
50.78°C
115.19V
80%
59.365A
7.955A
7.993A
2.316A
799.843
89.454%
1736
42.7
44.22°C
0.997
12.161V
5.03V
3.303V
4.967V
894.135
51.46°C
115.2V
90%
67.194A
8.453A
8.481A
2.421A
899.638
88.624%
1905
44.4
45.22°C
0.997
12.161V
5.029V
3.301V
4.957V
1015.124
53.59°C
115.2V
100%
75.123A
8.952A
9.001A
2.527A
1000.373
87.778%
2073
45.9
46.17°C
0.997
12.156V
5.027V
3.3V
4.948V
1139.663
56.58°C
115.2V
CL1
0.115A
11.955A
12.055A
0A
101.304
83.434%
1205
33.7
41.21°C
0.966
12.156V
5.036V
3.293V
5.06V
121.418
46.74°C
115.2V
CL2
0.115A
19.885A
0A
0A
101.397
82.801%
1008
28.1
40.5°C
0.965
12.159V
5.029V
3.321V
5.07V
122.459
48.22°C
115.19V
CL3
0.115A
0A
20.158A
0A
67.39
77.503%
921
25.8
40.73°C
0.949
12.157V
5.044V
3.274V
5.058V
86.952
49.89°C
115.19V
CL4
82.236A
0A
0A
0A
1000.106
88.799%
1896
44.3
46.85°C
0.997
12.161V
5.031V
3.322V
5.024V
1126.27
57.03°C
115.18V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.450A
1.985A
1.989A
0.99A
100.021
88.062%
646
13.9
40.45°C
0.785
12.160V
5.039V
3.318V
5.051V
113.58
44.7°C
230.4V
20%
13.910A
2.978A
2.986A
1.191A
199.977
91.935%
701
18.1
40.7°C
0.909
12.156V
5.037V
3.315V
5.039V
217.521
45.03°C
230.4V
30%
21.720A
3.476A
3.485A
1.393A
300.036
93.019%
814
22.4
41.82°C
0.951
12.153V
5.036V
3.314V
5.027V
322.553
46.45°C
230.41V
40%
29.507A
3.973A
3.985A
1.595A
399.834
93.347%
1008
28.1
42.35°C
0.965
12.154V
5.035V
3.313V
5.015V
428.33
47.09°C
230.42V
50%
36.942A
4.968A
4.986A
1.799A
499.534
93.294%
1172
32.8
42.83°C
0.972
12.155V
5.034V
3.31V
5.003V
535.441
48.03°C
230.42V
60%
44.444A
5.963A
5.988A
2.001A
600.071
92.992%
1350
36.5
43.04°C
0.977
12.157V
5.033V
3.307V
4.991V
645.295
48.56°C
230.42V
70%
51.877A
6.959A
6.991A
2.211A
699.838
92.616%
1521
39.4
43.08°C
0.981
12.158V
5.031V
3.305V
4.977V
755.641
49.6°C
230.43V
80%
59.372A
7.955A
7.996A
2.316A
799.868
92.198%
1704
42.1
43.37°C
0.984
12.159V
5.03V
3.302V
4.967V
867.55
50.73°C
230.43V
90%
67.199A
8.454A
8.484A
2.421A
899.648
91.753%
1855
43.8
44.49°C
0.987
12.161V
5.028V
3.3V
4.957V
980.506
52.7°C
230.43V
100%
75.132A
8.953A
9.003A
2.527A
1000.386
91.195%
2060
45.8
46.97°C
0.989
12.155V
5.027V
3.299V
4.948V
1096.976
56.44°C
230.44V
CL1
0.115A
11.957A
12.06A
0A
101.311
84.329%
1308
35.7
44.5°C
0.802
12.155V
5.035V
3.292V
5.06V
120.137
50.04°C
230.42V
CL2
0.115A
19.89A
0A
0A
101.399
83.691%
1146
32.1
43.1°C
0.809
12.158V
5.028V
3.321V
5.07V
121.158
49.56°C
230.41V
CL3
0.115A
0A
20.164A
0A
67.393
78.242%
1119
31.5
41.6°C
0.712
12.156V
5.044V
3.273V
5.058V
86.135
48.99°C
230.4V
CL4
82.246A
0A
0A
0A
1000.156
91.985%
1888
44.2
42.63°C
0.989
12.160V
5.031V
3.322V
5.023V
1087.307
52.38°C
230.42V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.221A
0.496A
0.497A
0.197A
20.003
68.352%
482
<6.0
37.37°C
0.757
12.165V
5.041V
3.322V
5.076V
29.265
40.8°C
115.19V
40W
2.688A
0.694A
0.695A
0.296A
40.001
79.366%
483
<6.0
37.48°C
0.878
12.164V
5.041V
3.322V
5.072V
50.401
40.96°C
115.19V
60W
4.154A
0.893A
0.894A
0.395A
60
83.888%
510
<6.0
38.85°C
0.927
12.163V
5.04V
3.321V
5.069V
71.523
42.62°C
115.19V
80W
5.618A
1.092A
1.093A
0.494A
79.959
86.006%
541
7.9
39.26°C
0.956
12.162V
5.04V
3.32V
5.064V
92.969
43.2°C
115.18V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.240A
0.5A
0.5A
0.2A
20.285
68.655%
490
<6.0
36.87°C
0.427
12.164V
5.041V
3.322V
5.076V
29.546
39.95°C
230.34V
40W
2.720A
0.7A
0.7A
0.3A
40.461
79.504%
540
7.9
37.42°C
0.559
12.163V
5.04V
3.321V
5.072V
50.892
40.83°C
230.34V
60W
4.155A
0.893A
0.894A
0.395A
60.002
84.552%
540
7.9
38.11°C
0.653
12.162V
5.04V
3.321V
5.067V
70.964
41.88°C
230.38V
80W
5.620A
1.092A
1.093A
0.494A
79.966
87.011%
585
12.4
39.42°C
0.731
12.161V
5.039V
3.32V
5.063V
91.903
43.5°C
230.39V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
5.7 mV
7.2 mV
7.8 mV
7.2 mV
Pass
20% Load
5.4 mV
8.1 mV
8.3 mV
7.4 mV
Pass
30% Load
5.7 mV
8.7 mV
9.5 mV
8.5 mV
Pass
40% Load
6.6 mV
8.8 mV
8.9 mV
8.4 mV
Pass
50% Load
7.3 mV
9.8 mV
11.1 mV
10.2 mV
Pass
60% Load
8.0 mV
9.3 mV
10.3 mV
40.4 mV
Pass
70% Load
10.7 mV
13.1 mV
11.7 mV
42.3 mV
Pass
80% Load
11.1 mV
12.8 mV
17.2 mV
39.9 mV
Pass
90% Load
11.5 mV
13.3 mV
18.7 mV
19.0 mV
Pass
100% Load
12.1 mV
14.4 mV
18.1 mV
14.2 mV
Pass
Crossload 1
7.9 mV
10.5 mV
16.2 mV
42.2 mV
Pass
Crossload 2
6.3 mV
7.9 mV
10.2 mV
39.0 mV
Pass
Crossload 3
7.7 mV
7.8 mV
15.4 mV
37.6 mV
Pass
Crossload 4
11.4 mV
13.1 mV
11.4 mV
44.9 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
5.4 mV
7.2 mV
7.6 mV
7.7 mV
Pass
20% Load
5.8 mV
7.9 mV
7.8 mV
7.7 mV
Pass
30% Load
5.6 mV
8.7 mV
9.1 mV
8.0 mV
Pass
40% Load
6.6 mV
8.8 mV
8.6 mV
8.0 mV
Pass
50% Load
7.3 mV
9.3 mV
9.0 mV
10.5 mV
Pass
60% Load
7.6 mV
9.4 mV
10.1 mV
9.7 mV
Pass
70% Load
10.5 mV
13.1 mV
11.8 mV
30.6 mV
Pass
80% Load
10.4 mV
13.1 mV
16.6 mV
31.2 mV
Pass
90% Load
10.5 mV
14.2 mV
16.8 mV
16.4 mV
Pass
100% Load
11.7 mV
15.0 mV
19.9 mV
11.0 mV
Pass
Crossload 1
7.6 mV
9.8 mV
16.4 mV
37.7 mV
Pass
Crossload 2
6.2 mV
7.8 mV
10.9 mV
39.2 mV
Pass
Crossload 3
7.7 mV
8.1 mV
16.2 mV
40.6 mV
Pass
Crossload 4
10.6 mV
13.3 mV
11.4 mV
44.8 mV
Pass
The results above are not used in the certification process
Super Flower Leadex V Pro Platinum 1000W
Top side
Power specifications label
ybenetics bietet die freiwilligen ETA- und Lambda-Zertifizierungsprogramme an, mit denen effiziente und leise Netzteile (PSU) beworben werden