40mm Magnetic Levitation Bearing Fan (MF40201VX-10000-A99)
Semi-Passive Operation
✗
Cybenetics Testing Information
Lab ID
SL60001980
Date of receipt
-
Testing Date
Feb 16, 2022
Report Issued Date
Feb 16, 2022
Engineer Name
-
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
Cables and Connectors(Non-accredited measurements)
Captive Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (490mm)
1
1
18-20AWG
No
8 pin EPS12V (490mm)
2
2
18AWG
No
6 pin PCIe (490mm)
1
1
18AWG
No
6 pin PCIe (430mm)
1
1
18AWG
No
4-pin Molex (490mm+150mm+150mm)
3
9
18AWG
No
4-pin Molex (490mm+150mm+150mm) / FDD (+150mm)
1
3 / 1
18-22AWG
No
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
NaN
NaN
49
3.5
NaN
Watts
NaN
588
17.5
NaN
Total Max. Power (W)
600
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
Performance Summary 230V
Accredited
Average Efficiency (>1450 load combinations)
85.820%
Average PF (>1450 Load Combinations)
0.930
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
1.9189W
Non-Accredited
12V Ripple (Full Load)
34.85mV
5VSB Ripple (Full Load)
13.70mV
12V Load Regulation
1.16%
5VSB Load Regulation
5.10%
Inrush Current
58.700A
Hold-Up Time & PWR_OK Signal
13.90ms
AC Loss to PWR_OK Hold Up Time
12.10ms
PWR_OK Inactive to DC Loss Delay
1.80ms
PSU Timings: T1 (20% / 100%)
132.0ms
126.0ms
PSU Timings: T3 (20% / 100%)
270.0ms
274.0ms
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
13.9
AC Loss to PWR_OK Hold Up Time (ms)
12.1
PWR_OK Inactive to DC Loss Delay (ms)
1.8
Vampire Power
Tables 230V
Graphs 230V
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.235W
10.377%
0.056
5.23V
2.265W
230.35V
2
0.09A
0.468W
18.165%
0.063
5.203V
2.577W
230.35V
3
0.55A
2.818W
50.762%
0.128
5.125V
5.551W
230.33V
4
1A
5.087W
59.881%
0.182
5.087V
8.495W
230.33V
5
1.5A
7.58W
64.359%
0.231
5.053V
11.778W
230.34V
6
3.5A
17.23W
69.475%
0.344
4.924V
24.8W
230.34V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
Main Rail
Standby Rail
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
10%
2.756A
0.982A
38.408
68.681%
34.56°C
0.683
12.123V
5.093V
55.922
38.73°C
230.24V
20%
5.845A
1.183A
76.819
78.986%
34.57°C
0.818
12.117V
5.07V
97.256
39.01°C
230.24V
30%
8.939A
1.387A
115.188
82.852%
35.2°C
0.892
12.102V
5.048V
139.029
39.89°C
230.24V
40%
12.045A
1.592A
153.641
84.614%
35.57°C
0.928
12.091V
5.026V
181.579
40.51°C
230.25V
50%
15.154A
1.798A
192.023
85.57%
35.96°C
0.947
12.077V
5.006V
224.403
41.52°C
230.25V
60%
18.281A
2A
230.447
86.006%
36.42°C
0.96
12.060V
4.985V
267.943
42.72°C
230.25V
70%
21.412A
2.217A
268.858
86.216%
36.9°C
0.965
12.043V
4.964V
311.842
44.24°C
230.25V
80%
24.596A
2.324A
307.298
86.202%
37.43°C
0.968
12.026V
4.95V
356.486
45.85°C
230.25V
90%
27.808A
2.432A
345.841
85.975%
38.57°C
0.973
12.005V
4.935V
402.256
47.58°C
230.25V
100%
30.977A
2.539A
383.913
85.572%
39.01°C
0.975
11.990V
4.924V
448.641
49.44°C
230.25V
110%
34.224A
2.541A
422.287
85.035%
40.45°C
0.975
11.974V
4.919V
496.605
51.71°C
230.24V
The results above are not used in the certification process
Light Load Tests 230V
Test
Main Rail
Standby Rail
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
20W
1.566A
0.193A
20.001
56.274%
31.36°C
0.569
12.128V
5.175V
35.542
34.4°C
230.22V
40W
3.176A
0.291A
40.007
71.01%
32.65°C
0.686
12.126V
5.156V
56.339
35.83°C
230.22V
60W
4.785A
0.389A
60.005
77.005%
33.55°C
0.763
12.123V
5.141V
77.924
36.98°C
230.22V
80W
6.392A
0.488A
79.95
80.372%
33.62°C
0.826
12.116V
5.127V
99.476
37.31°C
230.23V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
VSB
Pass/Fail
10% Load
8.61mV
7.84mV
Pass
20% Load
9.32mV
7.54mV
Pass
30% Load
10.68mV
7.79mV
Pass
40% Load
12.30mV
7.49mV
Pass
50% Load
14.38mV
8.04mV
Pass
60% Load
18.84mV
9.46mV
Pass
70% Load
22.03mV
9.87mV
Pass
80% Load
24.35mV
10.42mV
Pass
90% Load
28.45mV
11.84mV
Pass
100% Load
34.85mV
13.70mV
Pass
110% Load
39.13mV
14.07mV
Pass
The results above are not used in the certification process
SilverStone GM600 Silver
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics runs voluntary certification programs for power supplies - ETA for efficiency, LAMBDA for noise and SAFE for safety and correct operation - and for cooling products, with DELTA for chassis soundproofing and PHI for fan airflow and static pressure