Aristeidis Bitziopoulos, Certification Body General Manager
General Information
Main Specs
Product Identification Details
Brand
SilverStone
Model
Gemini 900A Gold
OEM
FSP
Serial Number
Product Specifications
Manufacturer
Rated Voltage (Vrms)
100-240
Rated Current (Arms)
10-6
Rated Frequency (Hz)
60-50
Rated Power (W)
930
Operating Temperature (Continuous Full Load) (°C)
Type
1U
Cable Design
Fixed cables
Warranty
-
Cybenetics
Dimensions (W x H x D)
Weight
Cooling
40mm Double Ball Bearing Fan (MDT4012PB-W28)
Semi-Passive Operation
✗
Cybenetics Testing Information
Lab ID
SL93002096
Date of receipt
Nov 10, 2022
Testing Date
Dec 1, 2022
Report Issued Date
Dec 1, 2022
Engineer Name
-
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
Cables and Connectors(Non-accredited measurements)
Protection Features(Non-accredited measurements)
Power Specifications(Manufacturer)
Rail
12V
5VSB
Max. Power
Amps
77.5
3
Watts
930
15
Total Max. Power (W)
930
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
(EU) No 617/2013 Compliance
Performance Summary 230V
Accredited
Average Efficiency (>1450 load combinations)
89.479%
Average Noise Output (>1450 Load Combinations)
0.00dBA
Average PF (>1450 Load Combinations)
0.947
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.8850W
Non-Accredited
12V Ripple (Full Load)
156.60mV
5V Ripple (Full Load)
0.00mV
3.3V Ripple (Full Load)
0.00mV
5VSB Ripple (Full Load)
43.74mV
12V Load Regulation
2.21%
5V Load Regulation
0.00%
3.3V Load Regulation
0.00%
5VSB Load Regulation
3.48%
Inrush Current
93.680A
Hold-Up Time & Power Ok Signal
0.00ms
AC Loss to PWR_OK Hold Up Time
0.00ms
PWR_OK Inactive to DC Loss Delay
0.00ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (28.28°C / 36.20°C)
113.17%
112.73%
Hold-Up Time & Power Ok Signal
Vampire Power
Tables 230V
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
229.89 V
229.86 V
227.70 V
229.94 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.00 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.14 %
0.12 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.885 W
0.818 W
N/A
0.949 W
N/A
N/A
Apparent Power:
35.129 W
35.097 W
N/A
35.165 W
N/A
N/A
Power Factor:
0.025
N/A
N/A
N/A
N/A
N/A
Graphs 230V
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
19.542%
0.033
5.123V
1.177W
229.9V
2
0.09A
0.46W
31.498%
0.041
5.117V
1.461W
229.89V
3
0.55A
2.799W
63.247%
0.12
5.092V
4.426W
229.91V
4
1A
5.076W
68.239%
0.187
5.077V
7.439W
229.9V
5
1.5A
7.597W
71.289%
0.228
5.065V
10.656W
229.9V
6
2.999A
15.071W
70.346%
0.345
5.026V
21.424W
229.9V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
Main Rail
Standby Rail
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
10%
7.146A
0.986A
92.973
87.028%
44.45°C
0.857
12.313V
5.069V
106.833
40.2°C
229.89V
20%
14.636A
1.187A
185.967
90.856%
44.84°C
0.934
12.296V
5.054V
204.688
40.34°C
229.88V
30%
22.157A
1.389A
278.969
91.788%
45.36°C
0.96
12.275V
5.04V
303.931
40.54°C
229.87V
40%
29.685A
1.591A
371.71
91.919%
46.62°C
0.972
12.253V
5.028V
404.386
41.42°C
229.85V
50%
37.320A
1.796A
464.725
91.478%
47.71°C
0.981
12.211V
5.009V
508.026
42.18°C
229.84V
60%
44.951A
1.999A
557.747
91.303%
48.44°C
0.985
12.186V
5.003V
610.861
42.27°C
229.83V
70%
52.588A
2.203A
650.76
90.754%
49.93°C
0.988
12.166V
4.989V
717.049
42.9°C
229.82V
80%
60.268A
2.308A
743.288
90.162%
51.21°C
0.989
12.142V
4.979V
824.379
43.12°C
229.81V
90%
68.102A
2.415A
836.557
89.712%
53.3°C
0.991
12.108V
4.966V
932.478
44.21°C
229.79V
100%
75.806A
3.036A
929.179
89.263%
55.12°C
0.991
12.060V
4.938V
1040.943
45.1°C
229.78V
110%
84.083A
3.04A
1022.794
88.727%
57.49°C
0.992
11.986V
4.931V
1152.756
46.59°C
229.76V
The results above are not used in the certification process
Light Load Tests 230V
Test
Main Rail
Standby Rail
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
20W
1.540A
0.196A
19.991
48.247%
39.87°C
0.418
12.327V
5.11V
30.077
36.81°C
229.9V
40W
3.124A
0.294A
39.993
78.4%
40.54°C
0.687
12.323V
5.101V
51.012
37.2°C
229.89V
60W
4.707A
0.392A
59.989
83.586%
41.71°C
0.777
12.320V
5.095V
71.769
38.24°C
229.89V
80W
6.287A
0.491A
79.92
86.377%
43.01°C
0.831
12.314V
5.09V
92.534
39.27°C
229.89V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5VSB
Pass/Fail
10% Load
73.46mV
29.90mV
Pass
20% Load
80.60mV
31.83mV
Pass
30% Load
83.79mV
37.44mV
Pass
40% Load
75.89mV
33.85mV
Pass
50% Load
89.36mV
40.94mV
Pass
60% Load
97.72mV
42.30mV
Pass
70% Load
104.25mV
37.75mV
Pass
80% Load
117.51mV
33.34mV
Pass
90% Load
141.20mV
42.97mV
Fail
100% Load
156.60mV
43.74mV
Fail
110% Load
168.30mV
11.19mV
Fail
The results above are not used in the certification process
SilverStone Gemini 900A Gold
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case