The TMX units are the same as TMX2 ones minus the 12VHPWR output port at the modular panel of the PSU
Engineer Name
-
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (600mm)
1
1
16-20AWG
No
4+4 pin EPS12V (700mm)
2
2
16AWG
No
6+2 pin PCIe (550mm+150mm)
3
6
16-18AWG
No
12+4 pin PCIe (600mm) (600W)
1
1
16-26AWG
No
SATA (510mm+150mm+150mm+150mm)
3
12
18AWG
No
4-pin Molex (510mm+150mm+150mm) / FDD (+150mm)
1
3 /1
18-22AWG
No
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
25
25
83.33
3
0.3
Watts
125
1000
15
3.6
Total Max. Power (W)
1000
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
89.027%
Average Noise Output (>1450 Load Combinations)
29.38dBA
Average PF (>1450 Load Combinations)
0.989
Efficiency With 10W (≤500W) or 2% (>500W) Load
64.100%
Standby Power Consumption
0.0756W
Non-Accredited
12V Ripple (Full Load)
35.60mV
5V Ripple (Full Load)
10.67mV
3.3V Ripple (Full Load)
20.35mV
5VSB Ripple (Full Load)
21.18mV
12V Load Regulation
0.32%
5V Load Regulation
1.84%
3.3V Load Regulation
3.25%
5VSB Load Regulation
1.98%
Inrush Current
69.600A
Accredited
Average Efficiency (>1450 load combinations)
91.424%
Average Noise Output (>1450 Load Combinations)
29.65dBA
Average PF (>1450 Load Combinations)
0.958
Efficiency With 10W (≤500W) or 2% (>500W) Load
65.101%
Standby Power Consumption
0.1218W
Non-Accredited
12V Ripple (Full Load)
34.31mV
5V Ripple (Full Load)
10.40mV
3.3V Ripple (Full Load)
22.46mV
5VSB Ripple (Full Load)
19.59mV
12V Load Regulation
0.36%
5V Load Regulation
1.84%
3.3V Load Regulation
3.25%
5VSB Load Regulation
1.94%
Inrush Current
87.070A
12V Transient Response (200%)
11.28V
5V Transient Response (200%)
4.912V
3.3V Transient Response (200%)
3.136V
5VSB Transient Response (200%)
4.885V
Hold-Up Time & PWR_OK Signal
19.60ms
AC Loss to PWR_OK Hold Up Time
15.10ms
PWR_OK Inactive to DC Loss Delay
4.50ms
PSU Timings: T1 (20% / 100%)
93.0ms
94.0ms
PSU Timings: T3 (20% / 100%)
122.0ms
122.0ms
OPP (30.60°C / 40.96°C)
150.12%
148.92%
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
19.6
AC Loss to PWR_OK Hold Up Time (ms)
15.1
PWR_OK Inactive to DC Loss Delay (ms)
4.5
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
114.86 V
114.81 V
113.85 V
114.89 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
60.00 Hz
59.40 Hz
60.02 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.416
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.17 %
0.13 %
N/A
0.24 %
2.00 %
PASS
Real Power:
0.076 W
0.038 W
N/A
0.108 W
N/A
N/A
Apparent Power:
9.472 W
8.985 W
N/A
9.793 W
N/A
N/A
Power Factor:
0.007
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
229.88 V
229.84 V
227.70 V
229.93 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.13 %
0.11 %
N/A
0.20 %
2.00 %
PASS
Real Power:
0.122 W
0.045 W
N/A
0.202 W
N/A
N/A
Apparent Power:
31.424 W
31.022 W
N/A
31.770 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
66.339%
0.038
5.111V
0.347W
114.94V
2
0.09A
0.46W
72.804%
0.068
5.11V
0.632W
114.94V
3
0.55A
2.807W
80.66%
0.271
5.103V
3.48W
114.94V
4
1A
5.096W
81.186%
0.342
5.095V
6.277W
114.93V
5
1.5A
7.632W
81.327%
0.391
5.087V
9.383W
114.93V
6
3A
15.19W
78.952%
0.455
5.063V
19.241W
114.92V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
53.163%
0.014
5.11V
0.434W
229.9V
2
0.09A
0.46W
64.248%
0.023
5.11V
0.717W
229.89V
3
0.55A
2.807W
78.049%
0.109
5.103V
3.596W
229.89V
4
1A
5.096W
79.318%
0.178
5.095V
6.427W
229.89V
5
1.5A
7.632W
80.065%
0.218
5.087V
9.533W
229.89V
6
3A
15.191W
79.227%
0.321
5.063V
19.174W
229.89V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.485A
1.967A
1.963A
0.983A
100.012
85.118%
873
22.2
40.16°C
0.965
12.091V
5.083V
3.361V
5.088V
117.498
44.52°C
114.91V
20%
13.989A
2.956A
2.954A
1.181A
199.969
89.444%
978
26.2
40.97°C
0.982
12.086V
5.074V
3.351V
5.079V
223.568
45.75°C
114.87V
30%
21.849A
3.455A
3.457A
1.38A
300.027
90.803%
1032
25.9
41.36°C
0.989
12.082V
5.066V
3.341V
5.071V
330.424
46.43°C
114.85V
40%
29.678A
3.954A
3.962A
1.58A
399.572
91.221%
1140
28.4
41.78°C
0.992
12.075V
5.058V
3.332V
5.063V
438.033
47.29°C
114.84V
50%
37.173A
4.952A
4.969A
1.781A
499.292
91.162%
1224
30.5
42.15°C
0.994
12.073V
5.049V
3.321V
5.054V
547.698
48.07°C
114.82V
60%
44.746A
5.954A
5.984A
1.982A
599.819
90.852%
1337
33.1
42.42°C
0.995
12.069V
5.039V
3.309V
5.046V
660.211
48.87°C
114.79V
70%
52.258A
6.963A
7.005A
2.184A
699.564
90.444%
1442
35.6
43.65°C
0.996
12.064V
5.028V
3.298V
5.037V
773.487
50.74°C
114.77V
80%
59.842A
7.975A
8.032A
2.287A
799.595
89.92%
1554
37.1
44.23°C
0.997
12.060V
5.017V
3.286V
5.029V
889.235
52.32°C
114.74V
90%
67.757A
8.487A
8.546A
2.39A
899.382
89.318%
1666
39.4
45.11°C
0.997
12.057V
5.008V
3.275V
5.022V
1006.944
54.19°C
114.7V
100%
75.477A
9.002A
9.096A
2.997A
999.395
88.58%
1802
41.6
45.79°C
0.997
12.053V
5V
3.265V
5.006V
1128.237
55.8°C
114.68V
110%
83.130A
10.024A
10.237A
3A
1100.01
87.765%
1858
43.9
47.63°C
0.998
12.050V
4.989V
3.252V
5V
1253.376
58.56°C
114.65V
CL1
0.116A
14.931A
14.903A
0A
126.308
81.019%
1266
32.1
43.97°C
0.973
12.096V
5.044V
3.328V
5.092V
155.899
49.48°C
114.89V
CL2
0.115A
24.835A
0A
0A
126.422
79.765%
1128
28.5
41.92°C
0.973
12.098V
5.034V
3.341V
5.099V
158.494
49.11°C
114.89V
CL4
82.933A
0A
0A
0.001A
999.859
89.461%
1714
40.6
47.67°C
0.997
12.056V
5.029V
3.288V
5.061V
1117.657
58.61°C
114.68V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.485A
1.967A
1.963A
0.983A
99.999
86.418%
864
22.1
40.68°C
0.845
12.089V
5.083V
3.361V
5.088V
115.719
44.92°C
229.88V
20%
13.989A
2.956A
2.954A
1.181A
199.948
90.952%
950
24.0
40.83°C
0.931
12.084V
5.074V
3.351V
5.079V
219.836
45.53°C
229.87V
30%
21.852A
3.455A
3.457A
1.38A
300.007
92.414%
1024
26.3
41.14°C
0.961
12.080V
5.066V
3.341V
5.071V
324.636
46.34°C
229.86V
40%
29.678A
3.954A
3.962A
1.58A
399.563
93.066%
1146
29.1
41.87°C
0.971
12.075V
5.058V
3.332V
5.063V
429.335
47.62°C
229.85V
50%
37.181A
4.953A
4.969A
1.781A
499.3
93.229%
1228
30.9
42.48°C
0.975
12.071V
5.048V
3.321V
5.054V
535.563
48.51°C
229.84V
60%
44.751A
5.955A
5.984A
1.982A
599.834
93.176%
1345
33.3
42.82°C
0.979
12.067V
5.039V
3.309V
5.045V
643.763
49.39°C
229.83V
70%
52.266A
6.963A
7.006A
2.184A
699.585
93.046%
1438
35.5
43.02°C
0.983
12.063V
5.028V
3.298V
5.036V
751.871
50.33°C
229.82V
80%
59.847A
7.974A
8.032A
2.287A
799.608
92.81%
1547
37.1
43.79°C
0.986
12.059V
5.018V
3.286V
5.029V
861.555
52.07°C
229.8V
90%
67.761A
8.485A
8.547A
2.39A
899.382
92.555%
1669
39.3
44.98°C
0.988
12.056V
5.01V
3.275V
5.022V
971.721
54.12°C
229.79V
100%
75.489A
9.002A
9.096A
2.996A
999.405
92.197%
1796
41.5
45.58°C
0.989
12.051V
5V
3.265V
5.007V
1083.99
55.66°C
229.78V
110%
83.140A
10.023A
10.237A
3A
1100.005
91.817%
1858
43.9
47.44°C
0.991
12.048V
4.989V
3.252V
5V
1198.033
58.34°C
229.77V
CL1
0.116A
14.929A
14.902A
0A
126.306
82.522%
1265
32.1
44.06°C
0.899
12.095V
5.045V
3.328V
5.092V
153.064
49.53°C
229.88V
CL2
0.115A
24.835A
0A
0A
126.421
81.124%
1163
29.4
43.5°C
0.901
12.098V
5.034V
3.341V
5.098V
155.838
50.55°C
229.88V
CL4
82.929A
0A
0A
0.001A
999.914
92.927%
1745
40.4
45.91°C
0.989
12.057V
5.029V
3.287V
5.061V
1076.024
56.75°C
229.78V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.228A
0.491A
0.489A
0.196A
19.998
63.445%
772
19.1
36.79°C
0.838
12.091V
5.092V
3.371V
5.105V
31.519
39.85°C
114.91V
40W
2.704A
0.688A
0.685A
0.294A
39.998
74.463%
812
20.6
37.37°C
0.938
12.092V
5.09V
3.369V
5.102V
53.715
40.66°C
114.91V
60W
4.179A
0.884A
0.882A
0.392A
60
81.404%
809
20.9
38.78°C
0.961
12.091V
5.088V
3.367V
5.1V
73.702
42.57°C
114.91V
80W
5.651A
1.081A
1.079A
0.491A
79.958
83.99%
835
21.1
40.04°C
0.967
12.091V
5.087V
3.365V
5.097V
95.199
43.99°C
114.9V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.228A
0.491A
0.489A
0.196A
19.997
62.728%
802
20.2
36.88°C
0.482
12.095V
5.092V
3.371V
5.104V
31.88
39.95°C
229.89V
40W
2.704A
0.688A
0.686A
0.294A
39.997
76.201%
803
20.2
38.07°C
0.636
12.091V
5.09V
3.369V
5.102V
52.489
41.39°C
229.89V
60W
4.180A
0.884A
0.882A
0.392A
59.997
81.72%
823
21.0
38.22°C
0.732
12.090V
5.088V
3.367V
5.1V
73.423
41.76°C
229.89V
80W
5.651A
1.081A
1.079A
0.49A
79.949
84.963%
809
20.9
38.47°C
0.794
12.090V
5.087V
3.365V
5.097V
94.101
42.28°C
229.89V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
15.88mV
6.23mV
8.95mV
7.57mV
Pass
20% Load
23.30mV
6.54mV
10.84mV
8.65mV
Pass
30% Load
24.12mV
12.16mV
14.22mV
9.93mV
Pass
40% Load
21.82mV
16.09mV
15.29mV
10.64mV
Pass
50% Load
21.62mV
10.52mV
12.84mV
13.31mV
Pass
60% Load
21.67mV
7.25mV
14.62mV
12.08mV
Pass
70% Load
21.82mV
8.48mV
16.82mV
17.45mV
Pass
80% Load
22.59mV
9.09mV
16.32mV
16.58mV
Pass
90% Load
22.69mV
8.89mV
17.80mV
16.02mV
Pass
100% Load
35.60mV
10.67mV
20.35mV
21.18mV
Pass
110% Load
37.98mV
11.83mV
23.12mV
22.14mV
Pass
Crossload1
24.25mV
10.02mV
22.50mV
8.13mV
Pass
Crossload2
19.88mV
8.48mV
20.35mV
6.09mV
Pass
Crossload3
0.00mV
0.00mV
0.00mV
0.00mV
Pass
Crossload4
35.55mV
8.80mV
14.08mV
17.89mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
15.07mV
6.54mV
9.56mV
7.78mV
Pass
20% Load
22.85mV
6.64mV
10.23mV
9.21mV
Pass
30% Load
24.12mV
12.51mV
13.09mV
9.72mV
Pass
40% Load
22.74mV
15.78mV
15.09mV
10.54mV
Pass
50% Load
21.51mV
17.67mV
18.62mV
12.85mV
Pass
60% Load
21.41mV
7.51mV
14.27mV
12.49mV
Pass
70% Load
22.33mV
7.97mV
14.93mV
17.04mV
Pass
80% Load
22.59mV
8.32mV
16.31mV
15.92mV
Pass
90% Load
22.95mV
9.30mV
17.23mV
14.94mV
Pass
100% Load
34.31mV
10.40mV
22.46mV
19.59mV
Pass
110% Load
35.91mV
10.98mV
21.95mV
20.71mV
Pass
Crossload1
24.86mV
9.50mV
22.38mV
7.97mV
Pass
Crossload2
19.37mV
8.12mV
19.48mV
6.70mV
Pass
Crossload3
0.00mV
0.00mV
0.00mV
0.00mV
Pass
Crossload4
34.57mV
8.67mV
13.49mV
15.64mV
Pass
The results above are not used in the certification process