The TMX units are the same as TMX2 ones minus the 12VHPWR output port at the modular panel of the PSU
Engineer Name
-
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (600mm)
1
1
18-20AWG
No
4+4 pin EPS12V (700mm)
2
2
18AWG
No
6+2 pin PCIe (550mm+150mm)
3
6
18AWG
No
12+4 pin PCIe (600mm) (600W)
1
1
16-26AWG
No
SATA (500mm+150mm+150mm+150mm)
3
12
18AWG
No
4-pin Molex (510mm+150mm+150mm) / FDD (+150mm)
1
3 / 1
18-22AWG
No
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
20
20
70.83
3
0.3
Watts
120
850
15
3.6
Total Max. Power (W)
850
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
89.162%
Average Noise Output (>1450 Load Combinations)
28.38dBA
Average PF (>1450 Load Combinations)
0.988
Efficiency With 10W (≤500W) or 2% (>500W) Load
66.827%
Standby Power Consumption
0.0447W
Non-Accredited
12V Ripple (Full Load)
39.60mV
5V Ripple (Full Load)
12.57mV
3.3V Ripple (Full Load)
32.71mV
5VSB Ripple (Full Load)
23.97mV
12V Load Regulation
0.96%
5V Load Regulation
1.67%
3.3V Load Regulation
3.18%
5VSB Load Regulation
2.38%
Inrush Current
71.970A
Accredited
Average Efficiency (>1450 load combinations)
91.239%
Average Noise Output (>1450 Load Combinations)
29.67dBA
Average PF (>1450 Load Combinations)
0.952
Efficiency With 10W (≤500W) or 2% (>500W) Load
65.537%
Standby Power Consumption
0.1036W
Non-Accredited
12V Ripple (Full Load)
39.48mV
5V Ripple (Full Load)
12.25mV
3.3V Ripple (Full Load)
32.42mV
5VSB Ripple (Full Load)
21.37mV
12V Load Regulation
0.99%
5V Load Regulation
1.67%
3.3V Load Regulation
3.22%
5VSB Load Regulation
2.42%
Inrush Current
88.590A
12V Transient Response (200%)
11.24V
5V Transient Response (200%)
4.924V
3.3V Transient Response (200%)
3.171V
5VSB Transient Response (200%)
4.942V
Hold-Up Time & PWR_OK Signal
14.40ms
AC Loss to PWR_OK Hold Up Time
13.20ms
PWR_OK Inactive to DC Loss Delay
1.20ms
PSU Timings: T1 (20% / 100%)
90.0ms
93.0ms
PSU Timings: T3 (20% / 100%)
121.0ms
121.0ms
OPP (27.59°C / 45.87°C)
142.59%
123.81%
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
14.4
AC Loss to PWR_OK Hold Up Time (ms)
13.2
PWR_OK Inactive to DC Loss Delay (ms)
1.2
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
114.84 V
114.80 V
113.85 V
114.88 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.02 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.15 %
0.12 %
N/A
0.19 %
2.00 %
PASS
Real Power:
0.045 W
0.003 W
N/A
0.077 W
N/A
N/A
Apparent Power:
9.853 W
9.824 W
N/A
9.887 W
N/A
N/A
Power Factor:
0.006
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
229.88 V
229.85 V
227.70 V
229.93 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.14 %
0.12 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.104 W
0.072 W
N/A
0.146 W
N/A
N/A
Apparent Power:
34.207 W
34.162 W
N/A
34.244 W
N/A
N/A
Power Factor:
0.003
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
66.392%
0.038
5.129V
0.347W
114.85V
2
0.09A
0.461W
73.637%
0.068
5.128V
0.626W
114.84V
3
0.55A
2.814W
80.514%
0.273
5.118V
3.495W
114.85V
4
1A
5.108W
81.205%
0.344
5.109V
6.29W
114.85V
5
1.5A
7.647W
80.993%
0.392
5.099V
9.441W
114.84V
6
2.999A
15.195W
78.554%
0.454
5.067V
19.344W
114.85V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231W
56.88%
0.013
5.128V
0.408W
229.92V
2
0.09A
0.461W
66.046%
0.023
5.127V
0.698W
229.91V
3
0.55A
2.814W
78.298%
0.11
5.118V
3.593W
229.9V
4
1A
5.108W
79.764%
0.179
5.108V
6.404W
229.89V
5
1.5A
7.646W
79.79%
0.22
5.098V
9.582W
229.9V
6
2.999A
15.192W
79.043%
0.321
5.066V
19.224W
229.89V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
5.292A
1.963A
1.944A
0.98A
84.985
86.725%
838
23.0
39.31°C
0.98
11.980V
5.095V
3.393V
5.101V
97.993
43.61°C
114.84V
20%
11.608A
2.949A
2.926A
1.178A
169.905
90.079%
841
23.2
40.96°C
0.977
11.975V
5.087V
3.383V
5.091V
188.618
45.76°C
114.82V
30%
18.292A
3.446A
3.423A
1.377A
254.889
91.228%
854
23.0
41.34°C
0.986
11.963V
5.078V
3.374V
5.082V
279.395
46.64°C
114.78V
40%
24.998A
3.944A
3.922A
1.577A
339.957
91.405%
995
26.2
42.09°C
0.99
11.951V
5.07V
3.365V
5.072V
371.922
47.77°C
114.77V
50%
31.330A
4.939A
4.92A
1.778A
424.52
91.129%
1146
30.3
42.62°C
0.992
11.938V
5.062V
3.353V
5.061V
465.841
48.76°C
114.75V
60%
37.672A
5.936A
5.923A
1.98A
509.042
90.703%
1223
29.7
42.85°C
0.994
11.925V
5.054V
3.342V
5.051V
561.222
49.59°C
114.72V
70%
44.100A
6.938A
6.935A
2.181A
594.4
90.157%
1367
32.6
43.17°C
0.995
11.912V
5.045V
3.331V
5.04V
659.295
50.21°C
114.7V
80%
50.542A
7.945A
7.951A
2.285A
679.25
89.45%
1516
35.4
43.8°C
0.996
11.899V
5.036V
3.318V
5.03V
759.366
51.84°C
114.68V
90%
57.403A
8.452A
8.46A
2.389A
764.663
88.697%
1634
39.2
44.73°C
0.996
11.885V
5.027V
3.308V
5.021V
862.112
54.1°C
114.66V
100%
64.013A
8.965A
9.001A
2.997A
849.508
87.808%
1743
39.7
45.23°C
0.997
11.871V
5.018V
3.298V
5.003V
967.467
55.24°C
114.63V
110%
70.492A
9.979A
10.129A
3.001A
934.034
86.752%
1838
40.9
46.72°C
0.996
11.858V
5.009V
3.286V
4.997V
1076.68
57.66°C
114.6V
CL1
0.115A
14.179A
14.238A
0A
121.246
82.994%
1062
26.2
39.88°C
0.975
11.983V
5.091V
3.349V
5.108V
146.089
45.39°C
114.82V
CL2
0.114A
19.553A
0A
0A
101.366
83.176%
875
23.3
38.13°C
0.976
11.989V
5.114V
3.365V
5.117V
121.868
45.37°C
114.82V
CL3
0.114A
0A
19.611A
0A
67.354
76.184%
854
23.0
40.58°C
0.973
11.980V
5.071V
3.364V
5.113V
88.407
49.68°C
114.84V
CL4
71.554A
0A
0A
0.001A
849.383
88.042%
1749
39.5
44.9°C
0.996
11.872V
5.019V
3.327V
5.075V
964.746
55.82°C
114.63V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
5.290A
1.963A
1.945A
0.98A
84.984
87.557%
842
23.2
40.11°C
0.808
11.982V
5.094V
3.393V
5.101V
97.065
44.51°C
229.88V
20%
11.604A
2.949A
2.927A
1.178A
169.899
91.409%
845
23.5
40.85°C
0.917
11.979V
5.085V
3.382V
5.091V
185.861
45.65°C
229.87V
30%
18.286A
3.446A
3.424A
1.378A
254.89
92.692%
900
24.4
41.08°C
0.951
11.968V
5.078V
3.373V
5.081V
274.981
46.31°C
229.86V
40%
24.989A
3.945A
3.924A
1.578A
339.961
93.037%
1006
25.8
41.54°C
0.963
11.956V
5.069V
3.363V
5.071V
365.402
47.2°C
229.85V
50%
31.320A
4.94A
4.921A
1.778A
424.59
92.97%
1109
28.8
42.47°C
0.973
11.945V
5.061V
3.352V
5.06V
456.695
48.54°C
229.84V
60%
37.658A
5.938A
5.926A
1.98A
509.122
92.746%
1235
30.5
42.93°C
0.977
11.932V
5.053V
3.341V
5.05V
548.943
49.46°C
229.83V
70%
44.080A
6.938A
6.937A
2.182A
594.432
92.453%
1331
33.5
43.18°C
0.98
11.918V
5.045V
3.33V
5.039V
642.964
50.39°C
229.82V
80%
50.521A
7.943A
7.951A
2.285A
679.261
92.011%
1458
35.1
43.47°C
0.982
11.904V
5.037V
3.318V
5.03V
738.243
51.73°C
229.81V
90%
57.380A
8.45A
8.459A
2.388A
764.651
91.545%
1609
38.0
44.19°C
0.984
11.889V
5.028V
3.308V
5.022V
835.272
53.29°C
229.8V
100%
63.997A
8.967A
9.004A
2.998A
849.485
90.897%
1719
39.3
45.17°C
0.986
11.873V
5.017V
3.297V
5.002V
934.556
55.18°C
229.79V
110%
70.496A
9.983A
10.135A
3.002A
934.06
90.248%
1836
40.6
46.52°C
0.988
11.857V
5.007V
3.284V
4.995V
1035
57.46°C
229.78V
CL1
0.115A
14.185A
14.248A
0A
121.252
84.573%
921
25.3
40.25°C
0.886
11.983V
5.089V
3.347V
5.108V
143.373
45.68°C
229.88V
CL2
0.115A
19.555A
0A
0A
101.367
84.188%
948
24.4
41.21°C
0.858
11.990V
5.113V
3.364V
5.116V
120.404
48.44°C
229.88V
CL3
0.115A
0A
19.611A
0A
67.362
76.59%
1044
28.1
42.57°C
0.782
11.980V
5.07V
3.365V
5.112V
87.953
51.66°C
229.89V
CL4
71.543A
0A
0A
0.001A
849.349
91.516%
1721
39.3
45.03°C
0.986
11.873V
5.018V
3.326V
5.075V
928.096
55.98°C
229.79V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.238A
0.49A
0.485A
0.195A
19.989
69.962%
830
24.3
36.57°C
0.83
11.985V
5.102V
3.403V
5.122V
28.569
39.66°C
114.84V
40W
2.727A
0.686A
0.679A
0.293A
39.987
80.313%
834
22.3
37.13°C
0.92
11.984V
5.099V
3.4V
5.119V
49.787
40.47°C
114.84V
60W
4.216A
0.883A
0.874A
0.391A
59.986
83.902%
838
23
38.07°C
0.96
11.982V
5.096V
3.398V
5.115V
71.499
41.86°C
114.83V
80W
5.703A
1.079A
1.069A
0.489A
79.941
86.88%
834
22.3
39.11°C
0.977
11.979V
5.096V
3.396V
5.112V
92.013
43.01°C
114.83V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.237A
0.49A
0.485A
0.195A
19.981
69.409%
832
22.3
36.54°C
0.467
11.990V
5.101V
3.403V
5.123V
28.79
39.59°C
229.89V
40W
2.726A
0.686A
0.679A
0.293A
39.981
80.579%
832
22.3
37.1°C
0.625
11.987V
5.099V
3.401V
5.12V
49.619
40.44°C
229.89V
60W
4.214A
0.883A
0.873A
0.391A
59.981
85.188%
838
23
38.16°C
0.725
11.985V
5.096V
3.398V
5.116V
70.408
41.69°C
229.88V
80W
5.699A
1.079A
1.068A
0.489A
79.916
87.739%
838
23
39.03°C
0.791
11.983V
5.095V
3.396V
5.113V
91.083
42.91°C
229.88V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
20.23mV
11.28mV
14.56mV
11.69mV
Pass
20% Load
29.95mV
7.06mV
16.68mV
11.64mV
Pass
30% Load
26.10mV
7.57mV
17.29mV
12.19mV
Pass
40% Load
28.53mV
14.28mV
19.77mV
13.51mV
Pass
50% Load
27.01mV
13.36mV
20.78mV
15.23mV
Pass
60% Load
25.45mV
11.89mV
22.70mV
16.65mV
Pass
70% Load
24.84mV
15.45mV
24.47mV
15.84mV
Pass
80% Load
24.33mV
13.57mV
28.51mV
17.91mV
Pass
90% Load
24.89mV
10.52mV
29.17mV
17.00mV
Pass
100% Load
39.60mV
12.57mV
32.71mV
23.97mV
Pass
110% Load
42.79mV
13.94mV
35.34mV
30.13mV
Pass
Crossload1
42.00mV
12.24mV
33.50mV
15.56mV
Pass
Crossload2
33.64mV
9.15mV
30.79mV
12.50mV
Pass
Crossload3
10.43mV
16.92mV
31.95mV
12.90mV
Pass
Crossload4
39.20mV
10.86mV
20.42mV
21.05mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
18.51mV
11.94mV
14.31mV
12.65mV
Pass
20% Load
30.71mV
10.11mV
16.43mV
12.14mV
Pass
30% Load
27.72mV
13.11mV
16.93mV
13.51mV
Pass
40% Load
29.50mV
16.77mV
20.27mV
13.71mV
Pass
50% Load
28.18mV
11.58mV
19.56mV
13.97mV
Pass
60% Load
26.51mV
11.79mV
22.19mV
15.08mV
Pass
70% Load
25.09mV
9.20mV
23.96mV
14.93mV
Pass
80% Load
25.60mV
10.42mV
29.37mV
15.53mV
Pass
90% Load
26.76mV
14.58mV
30.89mV
16.09mV
Pass
100% Load
39.48mV
12.25mV
32.42mV
21.37mV
Pass
110% Load
39.44mV
12.92mV
34.56mV
21.52mV
Pass
Crossload1
32.80mV
11.64mV
35.17mV
14.17mV
Pass
Crossload2
34.30mV
9.25mV
31.14mV
12.34mV
Pass
Crossload3
20.86mV
16.21mV
37.51mV
13.21mV
Pass
Crossload4
37.98mV
10.28mV
19.37mV
18.81mV
Pass
The results above are not used in the certification process
Zalman TeraMax II 850W