The TMX units are the same as TMX2 ones minus the 12VHPWR output port at the modular panel of the PSU
Engineer Name
-
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
线材与接头(Non-accredited measurements)
模组化线材
描述
线材数量
总连接器数量
Gauge
In Cable Capacitors
ATX 接头 20+4 pin (600mm)
1
1
18-20AWG
否
4+4 pin EPS 12V 接头 (700mm)
2
2
18AWG
否
6+2pin PCIe接头 (550mm+150mm)
3
6
18AWG
否
12+4 pin PCIe (600mm) (600W)
1
1
16-26AWG
否
SATA接头 (500mm+150mm+150mm+150mm)
2
8
18AWG
否
4-pin Molex (+500mm+150mm+150mm) / FDD (+150mm)
1
3 / 1
18-22AWG
否
电源规范
组
3.3V
5V
12V
5VSB
-12V
最大功率
安培
20
20
62.5
3
0.3
瓦
120
750
15
3.6
最大总功率 (W)
750
Test Results
Temperature & Compliance Info
温度范围 (°C /°F)
28-32 / 82.4-89.6
符合ErP Lot3/6规范
✓
符合(EU) No 617/2013规范
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Accredited
平均效率 (>1450 load combinations)
89.400%
Average Noise Output (>1450 Load Combinations)
27.38dBA
PF平均值 (>1450 Load Combinations)
0.988
Efficiency With 10W (≤500W) or 2% (>500W) Load
67.291%
待机功率耗损
0.0624W
Non-Accredited
12V Ripple (Full Load)
39.10mV
5V Ripple (Full Load)
17.02mV
3.3V Ripple (Full Load)
30.67mV
5VSB Ripple (Full Load)
19.41mV
12V Load Regulation
0.37%
5V Load Regulation
1.75%
3.3V Load Regulation
2.94%
5VSB Load Regulation
2.21%
Inrush Current
46.480A
Accredited
平均效率 (>1450 load combinations)
91.322%
Average Noise Output (>1450 Load Combinations)
27.52dBA
PF平均值 (>1450 Load Combinations)
0.941
Efficiency With 10W (≤500W) or 2% (>500W) Load
66.085%
待机功率耗损
0.1002W
Non-Accredited
12V Ripple (Full Load)
38.17mV
5V Ripple (Full Load)
21.65mV
3.3V Ripple (Full Load)
32.66mV
5VSB Ripple (Full Load)
19.16mV
12V Load Regulation
0.38%
5V Load Regulation
1.75%
3.3V Load Regulation
2.94%
5VSB Load Regulation
2.21%
Inrush Current
93.510A
12V Transient Response (200%)
11.50V
5V Transient Response (200%)
4.939V
3.3V Transient Response (200%)
3.177V
5VSB Transient Response (200%)
4.932V
保持时间 & PG信号
13.50ms
AC Loss to PWR_OK Hold Up Time
11.20ms
PWR_OK Inactive to DC Loss Delay
2.30ms
PSU Timings: T1 (20% / 100%)
93.0ms
91.0ms
PSU Timings: T3 (20% / 100%)
104.0ms
105.0ms
OPP (28.21°C / 36.23°C)
141.56%
130.88%
保持时间 & PG信号
Hold-Up Time (ms)
13.5
AC Loss to PWR_OK Hold Up Time (ms)
11.2
PWR_OK Inactive to DC Loss Delay (ms)
2.3
待机电源
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
114.88 V
114.82 V
113.85 V
114.93 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.94 Hz
59.40 Hz
60.04 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.418
1.417
1.340
1.421
1.490
PASS
Mains Voltage THD:
0.14 %
0.08 %
N/A
0.25 %
2.00 %
PASS
Real Power:
0.062 W
0.039 W
N/A
0.086 W
N/A
N/A
Apparent Power:
9.377 W
9.355 W
N/A
9.407 W
N/A
N/A
Power Factor:
0.008
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
229.89 V
229.83 V
227.70 V
229.97 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.417
1.490
PASS
Mains Voltage THD:
0.14 %
0.09 %
N/A
0.20 %
2.00 %
PASS
Real Power:
0.100 W
0.058 W
N/A
0.150 W
N/A
N/A
Apparent Power:
32.273 W
32.240 W
N/A
32.315 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
转换效率图表
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
噪音值图表
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC)
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.045A
0.229W
66.771%
0.038
5.1V
0.343W
114.87V
2
0.09A
0.459W
73.835%
0.069
5.099V
0.622W
114.87V
3
0.55A
2.799W
80.901%
0.276
5.089V
3.46W
114.87V
4
1A
5.08W
81.266%
0.351
5.08V
6.251W
114.86V
5
1.5A
7.604W
80.927%
0.398
5.069V
9.395W
114.87V
6
3A
15.109W
78.712%
0.461
5.036V
19.196W
114.86V
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.045A
0.229W
56.663%
0.013
5.097V
0.404W
229.89V
2
0.09A
0.459W
66.517%
0.023
5.097V
0.691W
229.88V
3
0.55A
2.799W
78.712%
0.111
5.089V
3.556W
229.88V
4
1A
5.079W
79.92%
0.181
5.079V
6.355W
229.87V
5
1.5A
7.603W
79.856%
0.229
5.068V
9.52W
229.88V
6
3A
15.109W
79.268%
0.33
5.036V
19.06W
229.88V
Protection Features
Supplementary Tests (For Reference)
10-110%负载测试
测试
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
温度(输入/输出)
PF/AC 电压
10%
4.410A
1.963A
1.967A
0.986A
74.992
85.477%
902
22.3
40.02°C
0.962
12.105V
5.093V
3.355V
5.07V
87.735
44.23°C
114.83V
20%
9.836A
2.95A
2.959A
1.186A
149.911
89.324%
910
22.6
40.8°C
0.977
12.100V
5.084V
3.345V
5.061V
167.83
45.39°C
114.81V
30%
15.615A
3.447A
3.461A
1.386A
224.907
90.79%
917
22.8
41.05°C
0.987
12.095V
5.076V
3.337V
5.052V
247.727
46.18°C
114.78V
40%
21.404A
3.946A
3.965A
1.586A
299.986
91.293%
956
24.3
41.88°C
0.991
12.090V
5.069V
3.329V
5.043V
328.598
47.51°C
114.77V
50%
26.794A
4.941A
4.971A
1.788A
374.305
91.273%
1063
26.6
42.12°C
0.993
12.085V
5.059V
3.319V
5.033V
410.098
48.27°C
114.74V
60%
32.237A
5.94A
5.984A
1.99A
449.229
91.028%
1150
29.2
42.56°C
0.994
12.080V
5.051V
3.309V
5.024V
493.505
49.25°C
114.72V
70%
37.685A
6.943A
7.003A
2.193A
524.166
90.673%
1264
31.8
43.43°C
0.995
12.075V
5.042V
3.299V
5.015V
578.088
50.5°C
114.69V
80%
43.203A
7.95A
8.028A
2.297A
599.4
90.149%
1385
33.8
43.68°C
0.996
12.071V
5.032V
3.288V
5.007V
664.892
51.77°C
114.67V
90%
49.059A
8.459A
8.537A
2.4A
674.437
89.664%
1552
37.1
44.65°C
0.996
12.066V
5.024V
3.279V
5V
752.19
53.66°C
114.64V
100%
54.719A
8.972A
9.081A
3.011A
749.667
88.996%
1650
39.0
45.78°C
0.997
12.061V
5.015V
3.27V
4.982V
842.361
55.85°C
114.61V
110%
60.251A
9.99A
10.217A
3.015A
824.705
88.244%
1792
41.4
46.9°C
0.997
12.057V
5.005V
3.259V
4.976V
934.571
57.84°C
114.58V
CL1
0.114A
14.309A
14.411A
0A
121.294
82.927%
935
23.5
40.57°C
0.974
12.097V
5.046V
3.31V
5.078V
146.265
45.98°C
114.81V
CL2
0.114A
19.819A
0A
0A
101.328
82.16%
926
23.1
40.92°C
0.974
12.104V
5.043V
3.336V
5.086V
123.329
47.93°C
114.83V
CL3
0.114A
0A
19.909A
0A
67.381
76.192%
920
22.9
40.18°C
0.963
12.101V
5.08V
3.315V
5.082V
88.436
49.22°C
114.84V
CL4
62.103A
0A
0A
0.001A
749.494
89.966%
1607
38.6
46.13°C
0.997
12.069V
5.047V
3.301V
5.052V
833.093
57.08°C
114.62V
The results above are not used in the certification process
测试
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
温度(输入/输出)
PF/AC 电压
10%
4.410A
1.963A
1.967A
0.986A
74.992
86.302%
894
22.2
40.08°C
0.739
12.105V
5.093V
3.355V
5.071V
86.896
44.29°C
229.87V
20%
9.836A
2.95A
2.959A
1.185A
149.91
90.823%
906
22.4
40.54°C
0.891
12.101V
5.084V
3.345V
5.061V
165.055
45.2°C
229.86V
30%
15.615A
3.447A
3.461A
1.386A
224.906
92.341%
916
22.8
41.45°C
0.937
12.095V
5.076V
3.337V
5.052V
243.563
46.53°C
229.85V
40%
21.404A
3.945A
3.965A
1.586A
299.986
92.934%
954
24.2
41.7°C
0.956
12.090V
5.069V
3.329V
5.043V
322.792
47.26°C
229.83V
50%
26.793A
4.941A
4.971A
1.788A
374.311
93.033%
1068
26.8
42.06°C
0.969
12.085V
5.06V
3.319V
5.033V
402.337
48.21°C
229.83V
60%
32.237A
5.94A
5.984A
1.99A
449.239
92.969%
1155
29.3
42.56°C
0.975
12.080V
5.05V
3.309V
5.024V
483.214
49.37°C
229.81V
70%
37.685A
6.944A
7.004A
2.193A
524.178
92.781%
1280
32.2
43.13°C
0.977
12.076V
5.041V
3.298V
5.015V
564.965
50.23°C
229.8V
80%
43.205A
7.951A
8.028A
2.296A
599.397
92.486%
1380
33.8
43.92°C
0.98
12.070V
5.031V
3.288V
5.007V
648.099
52.01°C
229.79V
90%
49.061A
8.46A
8.538A
2.4A
674.45
92.183%
1532
36.9
44.68°C
0.982
12.065V
5.023V
3.279V
5V
731.637
53.74°C
229.78V
100%
54.724A
8.972A
9.081A
3.011A
749.686
91.77%
1628
38.8
43.87°C
0.984
12.060V
5.015V
3.27V
4.982V
816.916
53.95°C
229.76V
110%
60.258A
9.99A
10.216A
3.014A
824.717
91.342%
1781
41.1
46.5°C
0.986
12.055V
5.005V
3.259V
4.976V
902.888
57.39°C
229.75V
CL1
0.114A
14.318A
14.421A
0A
121.296
84.267%
1055
26.4
42.47°C
0.867
12.098V
5.043V
3.308V
5.076V
143.943
48.02°C
229.86V
CL2
0.114A
19.825A
0A
0A
101.334
83.418%
936
23.5
40.22°C
0.83
12.104V
5.041V
3.335V
5.086V
121.479
47.27°C
229.86V
CL3
0.114A
0A
19.914A
0A
67.382
76.914%
926
23.1
40.15°C
0.744
12.101V
5.079V
3.314V
5.081V
87.606
49.25°C
229.87V
CL4
62.108A
0A
0A
0.001A
749.514
92.719%
1592
38.3
45.33°C
0.984
12.068V
5.047V
3.301V
5.052V
808.377
56.25°C
229.76V
The results above are not used in the certification process
20-80瓦负载测试
测试
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
温度(输入/输出)
PF/AC 电压
20W
1.227A
0.49A
0.49A
0.196A
19.989
70.535%
843
21.8
36.53°C
0.748
12.096V
5.103V
3.366V
5.092V
28.497
39.63°C
114.85V
40W
2.702A
0.686A
0.687A
0.295A
39.99
80.33%
868
22.1
37.47°C
0.891
12.096V
5.1V
3.363V
5.088V
49.784
40.76°C
114.84V
60W
4.174A
0.882A
0.884A
0.393A
59.99
84.109%
884
22.2
38.72°C
0.944
12.104V
5.098V
3.36V
5.085V
71.327
42.48°C
114.84V
80W
5.642A
1.079A
1.081A
0.492A
79.923
86.954%
895
22.2
39.56°C
0.967
12.106V
5.096V
3.358V
5.081V
91.914
43.52°C
114.83V
The results above are not used in the certification process
测试
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
温度(输入/输出)
PF/AC 电压
20W
1.226A
0.49A
0.49A
0.196A
19.987
72.049%
855
22.1
36.97°C
0.413
12.097V
5.103V
3.366V
5.092V
27.737
40.11°C
229.89V
40W
2.702A
0.686A
0.687A
0.295A
39.988
81.797%
867
22.1
37.04°C
0.58
12.097V
5.101V
3.363V
5.089V
49.155
40.35°C
229.88V
60W
4.174A
0.882A
0.884A
0.393A
59.989
85.252%
877
22.2
38°C
0.667
12.104V
5.098V
3.36V
5.085V
70.367
41.52°C
229.88V
80W
5.642A
1.079A
1.081A
0.492A
79.921
87.579%
884
22.2
39.04°C
0.753
12.106V
5.096V
3.358V
5.081V
91.261
42.85°C
229.87V
The results above are not used in the certification process
纹波测量
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
17.75mV
13.24mV
14.88mV
8.93mV
Pass
20% Load
27.31mV
14.06mV
17.44mV
9.65mV
Pass
30% Load
25.93mV
14.22mV
23.65mV
10.16mV
Pass
40% Load
24.91mV
21.60mV
26.98mV
11.24mV
Pass
50% Load
24.20mV
14.88mV
33.66mV
15.55mV
Pass
60% Load
23.12mV
13.86mV
35.45mV
17.34mV
Pass
70% Load
22.76mV
14.06mV
35.19mV
14.26mV
Pass
80% Load
20.72mV
11.60mV
22.21mV
13.44mV
Pass
90% Load
24.96mV
12.88mV
27.29mV
15.03mV
Pass
100% Load
39.10mV
17.02mV
30.67mV
19.41mV
Pass
110% Load
42.54mV
23.26mV
35.83mV
20.53mV
Pass
Crossload1
41.51mV
23.62mV
30.72mV
11.36mV
Pass
Crossload2
22.76mV
22.02mV
26.52mV
9.60mV
Pass
Crossload3
17.08mV
20.63mV
16.37mV
10.31mV
Pass
Crossload4
38.58mV
16.52mV
23.83mV
16.83mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
16.93mV
13.50mV
14.06mV
8.82mV
Pass
20% Load
26.44mV
13.45mV
23.80mV
10.93mV
Pass
30% Load
25.99mV
14.11mV
28.06mV
10.21mV
Pass
40% Load
25.47mV
20.47mV
29.40mV
11.13mV
Pass
50% Load
24.04mV
18.58mV
33.81mV
15.60mV
Pass
60% Load
24.40mV
14.99mV
35.55mV
16.52mV
Pass
70% Load
23.48mV
11.60mV
26.88mV
14.26mV
Pass
80% Load
23.28mV
13.80mV
28.73mV
14.16mV
Pass
90% Load
24.09mV
15.60mV
30.63mV
15.09mV
Pass
100% Load
38.17mV
21.65mV
32.66mV
19.16mV
Pass
110% Load
39.66mV
21.73mV
33.71mV
19.99mV
Pass
Crossload1
34.99mV
22.82mV
29.86mV
10.80mV
Pass
Crossload2
24.50mV
21.30mV
28.63mV
10.16mV
Pass
Crossload3
17.03mV
19.97mV
16.72mV
9.54mV
Pass
Crossload4
36.18mV
16.22mV
22.24mV
15.70mV
Pass
The results above are not used in the certification process