| 115V | 230V | |
| Scheme: ETA-EMI PSU | ![]() |
![]() |
| 115V | 230V | |
![]() |
![]() |
Scheme: LAMBDA PSU |
Outside Validation Scope

| Load range | Points | Efficiency 115V | PF 115V |
|---|---|---|---|
| 0-<20 % | 228 | 86.69% | 0.959 |
| 20-<40 % | 331 | 91.38% | 0.989 |
| 40-<60 % | 327 | 91.88% | 0.994 |
| 60-<80 % | 333 | 91.40% | 0.996 |
| 80-100 % | 334 | 90.50% | 0.996 |
| 70-100 % (High-Load) | 498 | 90.73% | 0.996 |
| All (published average) | 1553 | 90.61% | 0.989 |
Informational. Not part of the ETA or LAMBDA rating.
| Load range | Noise 115V avg (loudest) | Fan off 115V |
|---|---|---|
| 0-<20 % | 5.0 (5.0) | 100% |
| 20-<40 % | 5.0 (5.0) | 84% |
| 40-<60 % | 5.0 (6.7) | 42% |
| 60-<80 % | 13.0 (28.2) | 1% |
| 80-100 % | 26.7 (34.7) | 0% |
| 70-100 % (High-Load) | 25.1 (34.7) | 0% |
| All (published average) | 20.3 (34.7) | 42% |
Informational. Not part of the ETA or LAMBDA rating.
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 44.6 °C | 0 RPM · <6.0 dB(A) · 44.6 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 45.4 °C | 0 RPM · <6.0 dB(A) · 45.4 °C | fan off in both |
| 50% | 374 RPM · <6.0 dB(A) · 42.2 °C | 374 RPM · <6.0 dB(A) · 42.2 °C | fan off in both |
| 100% | 1460 RPM · 46.6 dB(A) · 45.4 °C | 1460 RPM · 46.6 dB(A) · 45.4 °C | +0.0 dB(A) |
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 44.2 °C | 0 RPM · <6.0 dB(A) · 44.2 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 45.3 °C | 0 RPM · <6.0 dB(A) · 45.3 °C | fan off in both |
| 50% | 374 RPM · <6.0 dB(A) · 42.1 °C | 374 RPM · <6.0 dB(A) · 42.1 °C | fan off in both |
| 100% | 1470 RPM · 46.5 dB(A) · 45.6 °C | 1470 RPM · 46.5 dB(A) · 45.6 °C | +0.0 dB(A) |
Informational. Not part of the ETA or LAMBDA rating.