CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Raijintek Cratos 1000W
序号
Lab IDRJ10002332
Certification ID252332
  • Test Result Report ID: 24PS2332A
  • Certificate Issue Date: Jan 26, 2024
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

线材与接头(Non-accredited measurements)

电源规范

Test Results

Temperature & Compliance Info

Performance Summary

保持时间 & PG信号

待机电源

Tables

Graphs

转换效率图表

Efficiency and power factor by load range

84858687888990919293Average efficiency (%)85.6590.6390.9389.9487.8787.0792.2092.8892.4791.010-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 84115V230V
84858687888990919293Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 84115V230V
0.820.840.860.880.900.920.940.960.981.00Average power factor0.9680.9840.9910.9940.9950.8490.9520.9720.9800.9850-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.82115V230V
0.820.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.82115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %213 / 21385.65%87.07%0.9680.849
20-<40 %320 / 32090.63%92.20%0.9840.952
40-<60 %320 / 32090.93%92.88%0.9910.972
60-<80 %320 / 32089.94%92.47%0.9940.980
80-100 %328 / 32887.87%91.01%0.9950.985
70-100 % (High-Load)488 / 48888.42%91.42%0.9950.984
All (published average)1501 / 150189.24%91.41%0.9880.955

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1501 (115V) and 1501 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1000 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

噪音值图表

Noise by load range

High-Load Index (70-100 % load)
Noise 32.2 dB(A) at 115V and 31.4 dB(A) at 230V · loudest point 36.8 dB(A)
Efficiency 88.42% / 91.42% · power factor 0.995 / 0.984 (115V / 230V)
0510152025303540Average noise (dB(A))16.414.90-<20 %fan off 10%/33%17.017.020-<40 %fan off 0%/0%18.819.340-<60 %fan off 0%/0%24.024.560-<80 %fan off 0%/0%33.632.780-100 %fan off 0%/0%115V230V
010203040Average noise (dB(A))16.414.90-<20 %off 10%/33%17.017.020-<40 %off 0%/0%18.819.340-<60 %off 0%/0%24.024.560-<80 %off 0%/0%33.632.780-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %16.4 (17.0)14.9 (17.0)10% / 33%
20-<40 %17.0 (18.9)17.0 (18.9)0% / 0%
40-<60 %18.8 (22.3)19.3 (23.8)0% / 0%
60-<80 %24.0 (32.2)24.5 (33.1)0% / 0%
80-100 %33.6 (36.8)32.7 (36.8)0% / 0%
70-100 % (High-Load)32.2 (36.8)31.4 (36.8)0% / 0%
All (published average)27.7 (36.8)27.0 (36.8)1% / 5%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1501 (115V) and 1501 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1000 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature".

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%906 RPM · 17.2 dB(A) · 40.2 °C906 RPM · 17.2 dB(A) · 40.2 °C+0.0 dB(A)
20%921 RPM · 17.8 dB(A) · 41.0 °C921 RPM · 17.8 dB(A) · 41.0 °C+0.0 dB(A)
50%1083 RPM · 23.3 dB(A) · 42.2 °C1083 RPM · 23.3 dB(A) · 42.2 °C+0.0 dB(A)
100%1762 RPM · 37.8 dB(A) · 45.3 °C1762 RPM · 37.8 dB(A) · 45.3 °C+0.0 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%907 RPM · 17.2 dB(A) · 40.1 °C907 RPM · 17.2 dB(A) · 40.1 °C+0.0 dB(A)
20%916 RPM · 17.6 dB(A) · 40.5 °C916 RPM · 17.6 dB(A) · 40.5 °C+0.0 dB(A)
50%1091 RPM · 23.5 dB(A) · 42.1 °C1091 RPM · 23.5 dB(A) · 42.1 °C+0.0 dB(A)
100%1770 RPM · 37.9 dB(A) · 45.9 °C1770 RPM · 37.9 dB(A) · 45.9 °C+0.0 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

高环温电源转换效率

5Vsb转换效率

输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

10-110%负载测试

20-80瓦负载测试

纹波测量

Raijintek Cratos 1000W

Top side
Top side
Power specifications label
Power specifications label
本测试报告中包含的所有数据和图表均可在以下条件下由任何人使用:使用过程需提及测试结果由Cybenetics提供。
在任何情况下都应提供原始测试结果文档的网站链接
Cybenetics 提供自愿性认证计划:电源方面有 ETA(效率)、LAMBDA(噪声)与 SAFE(安全与正确运行);散热产品方面有 DELTA(机箱隔音)与 PHI(风扇风量与静压)
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus