Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (600mm)
1
1
18-22AWG
No
4+4 pin EPS12V (660mm)
2
2
18AWG
No
6+2 pin PCIe (700mm+80mm)
2
4
18AWG
No
SATA (410mm+110mm+110mm+110mm)
1
4
18AWG
No
SATA (300mm+150mm)
1
2
18AWG
No
4 pin Molex (450mm+120mm+120mm)
1
3
18AWG
No
4 pin Molex (350mm+120mm)
1
2
18AWG
No
4-pin Molex Adapter / SATA (150mm+150mm)
1
2
18AWG
No
FDD Adapter (+100mm)
1
1
22AWG
No
AC Power Cord (1370mm) - C13 coupler
1
1
18AWG
-
Protection Features(Manufacturer)
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
20
20
54
3
0.3
Watts
100
648
15
3.6
Total Max. Power (W)
650
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
92.425%
Average Noise Output (>1450 Load Combinations)
9.98dBA
Average PF (>1450 Load Combinations)
0.987
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.0550W
Non-Accredited
12V Ripple (Full Load)
16.73mV
5V Ripple (Full Load)
5.20mV
3.3V Ripple (Full Load)
8.53mV
5VSB Ripple (Full Load)
6.65mV
12V Load Regulation
0.04%
5V Load Regulation
0.24%
3.3V Load Regulation
0.33%
5VSB Load Regulation
1.41%
Inrush Current
31.657A
Accredited
Average Efficiency (>1450 load combinations)
93.907%
Average Noise Output (>1450 Load Combinations)
10.29dBA
Average PF (>1450 Load Combinations)
0.931
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.0863W
Non-Accredited
12V Ripple (Full Load)
19.49mV
5V Ripple (Full Load)
7.99mV
3.3V Ripple (Full Load)
9.30mV
5VSB Ripple (Full Load)
5.46mV
12V Load Regulation
0.28%
5V Load Regulation
0.14%
3.3V Load Regulation
0.15%
5VSB Load Regulation
1.15%
Inrush Current
61.536A
12V Transient Response (150%)
0.00V
5V Transient Response (150%)
V
3.3V Transient Response (150%)
V
5VSB Transient Response (150%)
V
Hold-Up Time & Power Ok Signal
28.60ms
AC Loss to PWR_OK Hold Up Time
23.50ms
PWR_OK Inactive to DC Loss Delay
5.10ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
0.00%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
28.6
AC Loss to PWR_OK Hold Up Time (ms)
23.5
PWR_OK Inactive to DC Loss Delay (ms)
5.1
待機電源消耗
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.208
65.204%
0.034
4.966V
0.319
115.07V
2
0.088A
0.435
72.621%
0.063
4.963V
0.599
115.09V
3
0.542A
2.682
79.940%
0.267
4.944V
3.355
115.07V
4
1.002A
4.938
80.686%
0.361
4.926V
6.120
115.07V
5
1.502A
7.365
79.760%
0.414
4.903V
9.234
115.08V
6
3.001A
14.542
79.556%
0.479
4.845V
18.279
115.08V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.208
58.427%
0.011
4.965V
0.356
230.28V
2
0.087A
0.434
67.707%
0.021
4.963V
0.641
230.28V
3
0.542A
2.681
77.107%
0.105
4.942V
3.477
230.25V
4
1.002A
4.935
79.201%
0.173
4.924V
6.231
230.26V
5
1.502A
7.364
79.922%
0.231
4.903V
9.214
230.27V
6
3.002A
14.510
78.683%
0.333
4.834V
18.441
230.27V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.534A
1.985A
1.986A
0.997A
64.778
90.337%
395
10.5
38.04°C
0.956
12.231V
5.026V
3.317V
5.004V
71.707
43.86°C
115.02V
2
8.089A
2.979A
2.985A
1.201A
129.809
92.894%
395
10.5
38.25°C
0.981
12.231V
5.025V
3.316V
4.999V
139.739
44.20°C
115.03V
3
12.988A
3.485A
3.498A
1.401A
194.969
93.444%
395
10.5
38.65°C
0.988
12.232V
5.024V
3.315V
4.993V
208.649
45.55°C
115.03V
4
17.876A
3.983A
3.980A
1.602A
259.838
93.840%
395
10.5
38.96°C
0.996
12.232V
5.022V
3.313V
4.988V
276.896
47.01°C
115.03V
5
22.426A
4.976A
4.978A
1.805A
324.799
93.614%
420
10.8
39.27°C
0.992
12.233V
5.020V
3.312V
4.984V
346.954
49.37°C
115.02V
6
26.979A
5.974A
5.976A
2.005A
389.787
93.318%
435
10.7
40.36°C
0.991
12.233V
5.020V
3.310V
4.979V
417.698
50.63°C
115.03V
7
31.519A
6.979A
6.978A
2.210A
454.723
92.959%
290
9.0
41.18°C
0.992
12.234V
5.019V
3.310V
4.975V
489.164
57.03°C
115.02V
8
36.068A
7.973A
7.979A
2.412A
519.682
92.545%
385
10.5
41.69°C
0.993
12.235V
5.018V
3.308V
4.970V
561.544
57.89°C
115.02V
9
41.044A
8.473A
8.494A
2.412A
584.760
92.133%
460
11.9
43.46°C
0.994
12.235V
5.017V
3.307V
4.970V
634.691
61.08°C
115.03V
10
45.759A
8.978A
8.982A
3.026A
649.638
91.627%
540
15.8
44.97°C
0.995
12.236V
5.016V
3.307V
4.955V
709.002
63.12°C
115.03V
11
51.068A
8.981A
8.983A
3.026A
714.584
91.146%
610
18.7
46.24°C
0.995
12.236V
5.015V
3.305V
4.953V
783.995
66.07°C
115.04V
CL1
0.102A
12.012A
12.003A
0.005A
101.471
89.060%
440
11.6
44.35°C
0.978
12.228V
5.026V
3.318V
5.048V
113.936
59.17°C
115.06V
CL2
53.978A
1.003A
1.002A
1.002A
673.938
91.878%
580
16.4
45.08°C
0.995
12.238V
5.018V
3.310V
4.995V
733.515
64.07°C
115.04V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.543A
1.990A
1.988A
0.999A
64.916
90.761%
0
<6.0
46.73°C
0.735
12.224V
5.027V
3.320V
5.007V
71.524
40.00°C
231.00V
2
8.060A
2.986A
2.981A
1.199A
129.395
93.703%
395
10.5
40.83°C
0.859
12.220V
5.026V
3.319V
5.004V
138.090
47.97°C
230.97V
3
12.973A
3.483A
3.465A
1.400A
194.477
94.652%
395
10.5
41.13°C
0.915
12.216V
5.025V
3.318V
5.000V
205.465
48.48°C
230.76V
4
17.889A
3.981A
3.977A
1.602A
259.663
94.905%
395
10.5
41.86°C
0.944
12.212V
5.025V
3.318V
4.995V
273.603
49.83°C
230.88V
5
22.483A
4.978A
4.973A
1.803A
324.977
94.910%
420
10.8
42.05°C
0.961
12.208V
5.024V
3.317V
4.992V
342.405
50.46°C
230.66V
6
27.011A
5.974A
5.967A
2.005A
389.473
94.797%
468
12.1
42.80°C
0.968
12.205V
5.023V
3.317V
4.989V
410.848
51.74°C
230.79V
7
31.607A
6.971A
6.966A
2.207A
454.795
94.616%
350
10.1
43.29°C
0.975
12.202V
5.023V
3.317V
4.986V
480.676
52.67°C
230.74V
8
36.209A
7.968A
7.959A
2.409A
520.099
94.353%
425
10.8
43.77°C
0.979
12.198V
5.022V
3.317V
4.984V
551.227
53.69°C
230.69V
9
41.212A
8.466A
8.444A
2.408A
585.007
94.134%
460
11.9
44.67°C
0.981
12.193V
5.021V
3.316V
4.984V
621.465
54.88°C
230.64V
10
45.949A
8.963A
8.958A
3.019A
649.819
93.818%
525
13.8
45.21°C
0.984
12.190V
5.021V
3.315V
4.969V
692.641
55.60°C
230.60V
11
51.286A
8.965A
8.960A
3.020A
714.633
93.609%
580
16.4
46.13°C
0.987
12.185V
5.021V
3.314V
4.969V
763.425
56.87°C
230.39V
CL1
0.139A
12.002A
11.999A
0.000A
101.906
89.766%
385
10.5
42.66°C
0.826
12.227V
5.025V
3.325V
5.061V
113.524
50.91°C
230.96V
CL2
54.002A
1.001A
0.999A
1.000A
671.245
94.176%
490
13.3
45.63°C
0.985
12.183V
5.024V
3.312V
5.001V
712.754
55.71°C
230.59V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.197A
0.490A
0.479A
0.197A
19.675
79.453%
0
<6.0
0.797
12.221V
5.031V
3.321V
5.026V
24.763
115.02V
2
2.414A
0.986A
0.992A
0.397A
39.770
87.607%
0
<6.0
0.908
12.232V
5.028V
3.318V
5.019V
45.396
307.51V
3
3.636A
1.483A
1.505A
0.596A
59.912
89.881%
395
10.5
0.952
12.232V
5.027V
3.318V
5.013V
66.657
115.02V
4
4.844A
1.986A
1.988A
0.796A
79.807
91.478%
395
10.5
0.964
12.231V
5.026V
3.316V
5.009V
87.242
115.02V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.194A
0.498A
0.483A
0.199A
19.707
78.608%
0
<6.0
0.454
12.225V
5.031V
3.321V
5.027V
25.070
231.02V
2
2.437A
0.995A
0.996A
0.399A
40.101
87.229%
0
<6.0
0.625
12.224V
5.028V
3.319V
5.020V
45.972
231.02V
3
3.612A
1.492A
1.476A
0.598A
59.548
90.412%
0
<6.0
0.715
12.223V
5.027V
3.319V
5.016V
65.863
231.01V
4
4.854A
1.990A
1.988A
0.798A
79.926
91.892%
0
<6.0
0.775
12.222V
5.027V
3.319V
5.012V
86.978
231.00V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
13.2 mV
3.6 mV
6.1 mV
3.3 mV
Pass
20% Load
14.5 mV
3.6 mV
6.1 mV
4.0 mV
Pass
30% Load
16.3 mV
3.4 mV
6.1 mV
4.0 mV
Pass
40% Load
12.5 mV
4.0 mV
7.0 mV
5.1 mV
Pass
50% Load
10.6 mV
4.1 mV
7.2 mV
4.5 mV
Pass
60% Load
10.8 mV
4.4 mV
7.6 mV
5.0 mV
Pass
70% Load
13.8 mV
4.3 mV
7.5 mV
5.2 mV
Pass
80% Load
15.3 mV
4.4 mV
7.8 mV
5.6 mV
Pass
90% Load
15.7 mV
4.5 mV
7.1 mV
5.6 mV
Pass
100% Load
16.7 mV
5.2 mV
8.5 mV
6.7 mV
Pass
110% Load
18.2 mV
5.5 mV
8.8 mV
6.8 mV
Pass
Crossload 1
15.5 mV
3.9 mV
6.6 mV
3.8 mV
Pass
Crossload 2
17.2 mV
5.1 mV
7.9 mV
5.3 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
13.6 mV
3.7 mV
4.9 mV
2.2 mV
Pass
20% Load
16.8 mV
4.3 mV
6.0 mV
2.5 mV
Pass
30% Load
18.5 mV
4.3 mV
6.0 mV
2.7 mV
Pass
40% Load
14.7 mV
4.8 mV
6.5 mV
3.0 mV
Pass
50% Load
12.8 mV
5.7 mV
7.2 mV
3.2 mV
Pass
60% Load
13.5 mV
6.4 mV
8.2 mV
4.1 mV
Pass
70% Load
16.2 mV
6.3 mV
7.9 mV
4.3 mV
Pass
80% Load
18.0 mV
6.2 mV
9.1 mV
4.5 mV
Pass
90% Load
18.6 mV
6.2 mV
9.1 mV
4.7 mV
Pass
100% Load
19.5 mV
8.0 mV
9.3 mV
5.5 mV
Pass
110% Load
22.2 mV
7.5 mV
9.8 mV
5.7 mV
Pass
Crossload 1
15.0 mV
7.7 mV
9.8 mV
3.5 mV
Pass
Crossload 2
21.9 mV
4.9 mV
5.3 mV
4.7 mV
Pass
The results above are not used in the certification process